Literature DB >> 19240517

Quilting suture in the donor site of the transverse rectus abdominis musculocutaneous flap in breast reconstruction.

Luís A Rossetto1, Elvio B Garcia, Luis F Abla, Miguel S Neto, Lydia M Ferreira.   

Abstract

BACKGROUND: The purpose of this study was to evaluate the effects of quilting suture (placement of stitches between the superficial fascia in the supraumbilical remaining flap and the musculoaponeurotic layer of the anterior abdominal wall) at the donor site of the transverse rectus abdominis musculocutaneous flap in breast reconstruction.
METHODS: There is a theory that the use of quilting suture, during the closure of the donor site with the abdominal flap, causes collapse of the dead space and enables the flap to rest, thus diminishing factors that may interfere in its adherence and help to reduce complications. Between January 2004 and March 2005, we performed 30 breast reconstructions using a unipedicled transverse rectus abdominis musculocutaneous flap. The sample was randomly distributed in 2 groups: 15 patients with quilting suture (group A) and 15 patients without quilting suture (group B). The study focused on daily drain output (mL), time to drain removal (days), and possible donor site complications (%).
RESULTS: Group A presented an average of 4.2 days for removal of the drain and group B, 6.93 days, with a statistically significant difference (P < 0.001). Concerning the total volume upon removal of the drain, group A presented an average of 434.7 mL and group B, 620.7 mL, with a statistically significant difference (P = 0.002). Group A presented 13.3% complications at the donor site and group B, 53.3%, with a statistically significant difference (P = 0.05).
CONCLUSIONS: The quilting suture in this study reduces the permanence of drains, total volume of tissue fluids upon drain removal, and complication rates.

Entities:  

Mesh:

Year:  2009        PMID: 19240517     DOI: 10.1097/SAP.0b013e318180c8e2

Source DB:  PubMed          Journal:  Ann Plast Surg        ISSN: 0148-7043            Impact factor:   1.539


  3 in total

1.  Factors associated with hernia and bulge formation at the donor site of the pedicled TRAM flap.

Authors:  Luis Antonio Rossetto; Luiz Eduardo Felipe Abla; Ronaldo Vidal; Elvio Bueno Garcia; Ricardo João Gonzalez; Luiz Henrique Gebrim; Miguel Sabino Neto; Lydia Masako Ferreira
Journal:  Eur J Plast Surg       Date:  2010-04-07

2.  A Prospective, Randomized, Multicenter Trial Assessing a Novel Lysine-Derived Urethane Adhesive in a Large Flap Surgical Procedure without Drains.

Authors:  Joseph P Hunstad; Joseph Michaels; A Jay Burns; Sheri Slezak; W Grant Stevens; Dottie M Clower; J Peter Rubin
Journal:  Aesthetic Plast Surg       Date:  2015-06-05       Impact factor: 2.326

3.  Technique for Minimizing Donor-site Morbidity after Pedicled TRAM-Flap Breast Reconstruction: Outcomes by a Single Surgeon's Experience.

Authors:  Mario Rietjens; Francesca De Lorenzi; Manconi Andrea; Jean-Yves Petit; Prakasit Chirappapha; Alaa Hamza; Stefano Martella; Benedetta Barbieri; Alessandra Gottardi; Lomeo Giuseppe
Journal:  Plast Reconstr Surg Glob Open       Date:  2015-08-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.