Literature DB >> 19237320

Development of a sensitive and selective method for the quantitative analysis of cortisol, cortisone, prednisolone and prednisone in human plasma.

Ileana A Ionita1, Douglas M Fast, Fatemeh Akhlaghi.   

Abstract

A highly selective, sensitive and robust LC-MS/MS method was developed for the simultaneous quantification of cortisol, cortisone, prednisolone and prednisone in human plasma. Prednisolone, cortisol and cortisone have similar fragmentation pattern. These three compounds were chromatographically separated, thus eliminating the inherent interference that fragments derived from the M+2 and M isotopes of prednisolone contribute in the MRM channels of cortisol and cortisone, respectively. Additionally, by using a small particle (1.8 microm) analytical column, interferences present in the plasma samples from post-transplant recipients were successfully resolved from cortisol after a simple extraction consisting of protein precipitation, evaporation and reconstitution. The chromatographic separation was achieved on a Zorbax-SB Phenyl column under isocratic conditions during a run time of 8 min. Intra-run and inter-run precision and accuracy within +/-15% were achieved during a 3-run validation for quality control samples at five concentration levels in charcoal-stripped plasma as well as in normal plasma, over a 500-fold dynamic concentration range. The lower limit of quantitation was 0.500 ng/mL for cortisone and prednisone, 1.00 ng/mL for cortisol and 2.00 ng/mL for prednisolone. The performance of the small particle column was maintained during more than 1200 injections in terms of peak retention time, symmetry and backpressure.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19237320     DOI: 10.1016/j.jchromb.2009.02.019

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  9 in total

1.  Development and validation of a fast and sensitive bioanalytical method for the quantitative determination of glucocorticoids--quantitative measurement of dexamethasone in rabbit ocular matrices by liquid chromatography tandem mass spectrometry.

Authors:  Ravinder Earla; Sai H S Boddu; Kishore Cholkar; Sudharshan Hariharan; Jwala Jwala; Ashim K Mitra
Journal:  J Pharm Biomed Anal       Date:  2010-01-18       Impact factor: 3.935

2.  Determination of cortisol production rates with contemporary liquid chromatography-mass spectrometry to measure cortisol-d(3) dilution after infusion of deuterated tracer.

Authors:  Bethany J Klopfenstein; Jonathan Q Purnell; David D Brandon; Lorne M Isabelle; Andrea E DeBarber
Journal:  Clin Biochem       Date:  2010-12-23       Impact factor: 3.281

3.  Pharmacokinetics of total and unbound prednisone and prednisolone in stable kidney transplant recipients with diabetes mellitus.

Authors:  Ileana A Ionita; Ken Ogasawara; Reginald Y Gohh; Fatemeh Akhlaghi
Journal:  Ther Drug Monit       Date:  2014-08       Impact factor: 3.681

Review 4.  The use of mass spectrometry to improve the diagnosis and the management of the HPA axis.

Authors:  Phillip J Monaghan; Brian G Keevil; Peter J Trainer
Journal:  Rev Endocr Metab Disord       Date:  2013-06       Impact factor: 6.514

Review 5.  Clinical pharmacokinetics and pharmacodynamics of prednisolone and prednisone in solid organ transplantation.

Authors:  Troels K Bergmann; Katherine A Barraclough; Katie J Lee; Christine E Staatz
Journal:  Clin Pharmacokinet       Date:  2012-11       Impact factor: 6.447

6.  Multiplexed analysis of steroid hormones in human serum using novel microflow tile technology and LC-MS/MS.

Authors:  Carolyn J Broccardo; Kevin L Schauer; Wendy M Kohrt; Robert S Schwartz; James P Murphy; Jessica E Prenni
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2013-07-04       Impact factor: 3.205

7.  Multisteroid LC-MS/MS assay for glucocorticoids and androgens, and its application in Addison's disease.

Authors:  Paal Methlie; Steinar Simon Hustad; Ralf Kellmann; Bjørg Almås; Martina Moter Erichsen; Eystein Husebye; Kristian Løvås
Journal:  Endocr Connect       Date:  2013-06-14       Impact factor: 3.335

8.  Application of LC-MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids.

Authors:  Jamshed Haneef; Mohammad Shaharyar; Asif Husain; Mohd Rashid; Ravinesh Mishra; Shama Parveen; Niyaz Ahmed; Manoj Pal; Deepak Kumar
Journal:  J Pharm Anal       Date:  2013-04-02

9.  Mapping the Steroid Response to Major Trauma From Injury to Recovery: A Prospective Cohort Study.

Authors:  Mark A Foster; Angela E Taylor; Neil E Hill; Conor Bentley; Jon Bishop; Lorna C Gilligan; Fozia Shaheen; Julian F Bion; Joanne L Fallowfield; David R Woods; Irina Bancos; Mark M Midwinter; Janet M Lord; Wiebke Arlt
Journal:  J Clin Endocrinol Metab       Date:  2020-03-01       Impact factor: 5.958

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.