Literature DB >> 19237189

Nanohybrid vs. fine hybrid composite in Class II cavities: clinical results and margin analysis after four years.

Norbert Krämer1, Christian Reinelt, Gert Richter, Anselm Petschelt, Roland Frankenberger.   

Abstract

OBJECTIVES: This controlled prospective split-mouth study evaluated the clinical behavior of two different resin composites in extended Class II cavities over a period of four years.
METHODS: Thirty patients received 68 direct resin composite restorations (Grandio bonded with Solobond M: n=36, Tetric Ceram bonded with Syntac: n=32) by one dentist in a private practice. All restorations were replacement fillings, 24 cavities (35%) revealed no enamel at the bottom of the proximal box, in 33 cavities (48%) the proximal enamel width was less than 0.5mm. The restorations were examined according to modified USPHS criteria at baseline, and after six months, one, two, and four years. At each recall, impressions were taken for replica preparation. Replicas of 44 select subjects were assessed for marginal quality under a stereo light microscope (SLM) at 130x and 22 replicas were assessed under a scanning electron microscope (SEM) at 200x.
RESULTS: Both recall rate and survival rate were 100% after four years of clinical service. No significant difference was found between the restorative materials (p>0.05; Mann-Whitney U-test). Hypersensitivities were significantly reduced over time (p<0.05; Friedman test). A significant deterioration over time was found for the criteria marginal integrity (66% bravo after four years), tooth integrity (15% bravo), filling integrity (73% bravo) and proximal contact (p<0.05; Friedman test). SLM and SEM analysis of restoration margins revealed differences in the amount of perfect margins, in favor of Tetric Ceram (p<0.05). SIGNIFICANCES: Both materials performed satisfactorily over the four-year observation period. Due to the extension of the restorations, wear was clearly visible after four years of clinical service with 50% bravo ratings.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19237189     DOI: 10.1016/j.dental.2008.12.003

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  3 in total

1.  Three-year randomised clinical trial to evaluate the clinical performance, quantitative and qualitative wear patterns of hybrid composite restorations.

Authors:  Senthamaraiselvi Palaniappan; Liesbeth Elsen; Inge Lijnen; Marleen Peumans; Bart Van Meerbeek; Paul Lambrechts
Journal:  Clin Oral Investig       Date:  2009-08-08       Impact factor: 3.573

2.  Clinical evaluation of resin-based composites in posterior restorations: a 3-year study.

Authors:  Çiğdem Çelik; Neslihan Arhun; Kivanc Yamanel
Journal:  Med Princ Pract       Date:  2014-08-12       Impact factor: 1.927

3.  Clinical evaluation of resin-based composites in posterior restorations: 12-month results.

Authors:  Cigdem Celik; Neslihan Arhun; Kivanc Yamanel
Journal:  Eur J Dent       Date:  2010-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.