Literature DB >> 19233366

Selective determination method for measurement of nitrite and nitrate in water samples using high-performance liquid chromatography with post-column photochemical reaction and chemiluminescence detection.

Hitoshi Kodamatani1, Shigeo Yamazaki, Keiitsu Saito, Takashi Tomiyasu, Yu Komatsu.   

Abstract

A simple, sensitive and selective method for the simultaneous determination of nitrite and nitrate in water samples has been developed. The method is based on ion-exchange separation, online photochemical reaction, and luminol chemiluminescence detection. The separation of nitrite and nitrate was achieved using an anion-exchange column with a 20mM borate buffer (pH 10.0). After the separation, these ions were converted to peroxynitrite by online UV irradiation using a low-pressure mercury lamp and then mixed with a luminol solution prepared with carbonate buffer (pH 10.0). The calibration graphs of the nitrite and nitrate were linear in the range from 2.0 x 10(-9) to 2.5 x 10(-6)M and 2.0 x 10(-8) to 2.5 x 10(-5)M, respectively. Since the sensitivity of nitrite was about 10 times higher than that of nitrate, the simultaneous determination of nitrite and nitrate in the water samples could be efficiently achieved. This method was successfully applied to various water samples--river water, pond water, rain water, commercial mineral water, and tap water--with only filtration and dilution steps.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19233366     DOI: 10.1016/j.chroma.2009.01.096

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  10 in total

1.  Polymeric optical sensors for selective and sensitive nitrite detection using cobalt(III) corrole and rhodium(III) porphyrin as ionophores.

Authors:  Si Yang; Yaqi Wo; Mark E Meyerhoff
Journal:  Anal Chim Acta       Date:  2014-06-26       Impact factor: 6.558

2.  Modified graphene oxide sensors for ultra-sensitive detection of nitrate ions in water.

Authors:  Wen Ren; Stefania Mura; Joseph M K Irudayaraj
Journal:  Talanta       Date:  2015-05-28       Impact factor: 6.057

3.  Application of capillary electrophoresis in anion binding studies: Complexation and separation of nitrate and nitrite by an azacryptand.

Authors:  Hao Wu; Musabbir A Saeed; Huey-Min Hwang; Shulin Zhao; Yi-Ming Liu; Md Alamgir Hossain
Journal:  J Phys Org Chem       Date:  2011-01       Impact factor: 2.391

4.  The Trace Detection of Nitrite Ions Using Neutral Red Functionalized SH-β-Cyclodextrin @Au Nanoparticles.

Authors:  Xiaoyang Du; Xiaoxia Zhang; Chunlai Jiang; Weilu Zhang; Lizhu Yang
Journal:  Sensors (Basel)       Date:  2018-02-25       Impact factor: 3.576

5.  Solid-State Heating Synthesis of Poly (3,4-Ethylenedioxythiophene)/Gold/Graphene Composite and Its Application for Amperometric Determination of Nitrite and Iodate.

Authors:  Ahmat Ali; Yu Zhang; Ruxangul Jamal; Tursun Abdiryim
Journal:  Nanoscale Res Lett       Date:  2017-10-17       Impact factor: 4.703

6.  HPLC-DAD Determination of Nitrite and Nitrate in Human Saliva Utilizing a Phosphatidylcholine Column.

Authors:  Małgorzata Tatarczak-Michalewska; Jolanta Flieger; Justyna Kawka; Wojciech Płaziński; Wojciech Flieger; Eliza Blicharska; Dariusz Majerek
Journal:  Molecules       Date:  2019-05-06       Impact factor: 4.411

7.  3D Microfluidic Devices in a Single Piece of Paper for the Simultaneous Determination of Nitrite and Thiocyanate.

Authors:  Peng Yu; Muhan Deng; Yi Yang; Beixi Nie; Shaoyu Zhao
Journal:  Sensors (Basel)       Date:  2020-07-24       Impact factor: 3.576

Review 8.  Removal of the Harmful Nitrate Anions from Potable Water Using Different Methods and Materials, including Zero-Valent Iron.

Authors:  Hany M Abd El-Lateef; Mai M Khalaf; Alaa El-Dien Al-Fengary; Mahmoud Elrouby
Journal:  Molecules       Date:  2022-04-14       Impact factor: 4.927

9.  Immobilization of myoglobin on Au nanoparticle-decorated carbon nanotube/polytyramine composite as a mediator-free H2O2 and nitrite biosensor.

Authors:  A T Ezhil Vilian; Vediyappan Veeramani; Shen-Ming Chen; Rajesh Madhu; Cheol Hwan Kwak; Yun Suk Huh; Young-Kyu Han
Journal:  Sci Rep       Date:  2015-12-17       Impact factor: 4.379

10.  Electrochemical Determination of Nitrite by Au Nanoparticle/Graphene-Chitosan Modified Electrode.

Authors:  Rijian Mo; Xuehua Wang; Qiong Yuan; Xiemin Yan; Tiantian Su; Yanting Feng; Lulu Lv; Chunxia Zhou; Pengzhi Hong; Shengli Sun; Zhe Wang; Chengyong Li
Journal:  Sensors (Basel)       Date:  2018-06-21       Impact factor: 3.576

  10 in total