Literature DB >> 19232669

Predicting odour emissions from wastewater treatment plants by means of odour emission factors.

Laura Capelli1, Selena Sironi, Renato Del Rosso, Paolo Céntola.   

Abstract

In this study, the results of odour concentration measurements on different wastewater treatment plants are presented and used in order to estimate the odour emission factors relevant to single odour sources. An odour emission factor is a representative value that relates the quantity of odour released to the atmosphere to a specific activity index, which in this case was the plant treatment capacity, resulting in an odour emission factor expressed in odour units per cubic metre of treated sewage. The results show that the major odour source of a wastewater treatment plant is represented by the primary sedimentation (with an OEF equal to 1.9 x 10(5)ou(E) m(-3)). In general, the highest OEFs are observed in correspondence of the first steps of the wastewater depuration cycle (OEF between 1.1 x 10(4)ou(E) m(-3) and 1.9 x 10(5)ou(E) m(-3)) and tend to decrease along the depuration process (OEF between 7.4 x 10(3)ou(E) m(-3) and 4.3 x 10(4)ou(E) m(-3)). In general, the OEFs calculated according to this approach represent a model for a rough prediction of odour emissions independently from the specific characteristics of the different plants.

Mesh:

Substances:

Year:  2009        PMID: 19232669     DOI: 10.1016/j.watres.2009.01.022

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  5 in total

1.  Integrated model for estimating odor emissions from civil wastewater treatment plants.

Authors:  Marco Ravina; Deborah Panepinto; Jheyson Mejia Estrada; Luca De Giorgio; Pietro Salizzoni; Mariachiara Zanetti; Lorenza Meucci
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-10       Impact factor: 4.223

2.  Assessment of the Indoor Odour Impact in a Naturally Ventilated Room.

Authors:  Lidia Eusebio; Marco Derudi; Laura Capelli; Giuseppe Nano; Selena Sironi
Journal:  Sensors (Basel)       Date:  2017-04-05       Impact factor: 3.576

3.  Evaluation of Health Hazard Due to Emission of Volatile Organic Compounds from Various Processing Units of Wastewater Treatment Plant.

Authors:  Hubert Byliński; Jacek Gębicki; Jacek Namieśnik
Journal:  Int J Environ Res Public Health       Date:  2019-05-16       Impact factor: 3.390

4.  Determination of Odor Air Quality Index (OAQII) Using Gas Sensor Matrix.

Authors:  Dominik Dobrzyniewski; Bartosz Szulczyński; Jacek Gębicki
Journal:  Molecules       Date:  2022-06-29       Impact factor: 4.927

5.  Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants.

Authors:  Jacek Gebicki; Hubert Byliński; Jacek Namieśnik
Journal:  Environ Monit Assess       Date:  2015-12-15       Impact factor: 2.513

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.