The use of postoperative slit-lamp optical coherence tomography to predict primary failure in descemet stripping automated endothelial keratoplasty.

Carolyn Y Shih1, David C Ritterband, Pat-Michael Palmiero, John A Seedor, George Papachristou, Noga Harizman, Jeffrey M Liebmann, Robert Ritch.   

Abstract

PURPOSE: To determine if central donor lenticle thickness as measured by slit-lamp optical coherence tomography (SL OCT; Heidelberg Engineering, Heidelberg, Germany) is predictive of primary donor failure in patients undergoing Descemet stripping automated endothelial keratoplasty (DSAEK).
DESIGN: Retrospective cross-sectional study.
METHODS: Eighty-four patients who underwent DSAEK surgery by 2 surgeons (D.C.R. and J.A.S.) were enrolled. At each postoperative visit (postoperative day 1, week 1, month 1, and month 2), an SL OCT scan was obtained. Statistical differences in SL OCT measurements of successful and failed DSAEK procedures were measured using the Student t test. A successful DSAEK surgery was defined as having an anatomically attached, clear recipient corneal stroma and donor lenticle compatible with good vision 2 months after surgery. A failed DSAEK surgery was defined as an attached donor lenticle with SL evidence of corneal edema and thickening visible at 2 months or more.
RESULTS: Ninety-three eyes of 84 consecutive patients who underwent DSAEK surgery also underwent postoperative SL OCT. After 2 months of follow-up, 82 (88%) procedures were successful and 11 (12%) procedures were failures. The average donor lenticle thickness in successful DSAEK eyes was 314 +/- 128 microm on postoperative day 1 as compared with failed DSAEK eyes, which averaged 532 +/- 259 microm (P = .0013). This was independent regardless of whether the lenticle was attached on the first postoperative visit. Seventy-nine (98%) successful DSAEK eyes had a lenticle thickness of < or = 350 microm at the 1-week visit. All of the failed DSAEK eyes (11 eyes) had a lenticle thickness > or = 350 microm at the 1-week postoperative visit. Statistically significant differences in SL OCT thickness measurements were seen between successful and failed DSAEK cases at all examinations after postoperative week 1.
CONCLUSIONS: Corneal thickness measurements made with SL OCT are an important predictor of DSAEK failure in both attached and detached lenticles within the first week of surgery. DSAEK lenticle thickness of 350 microm or less at 1 week had a predictability of success of more than 98%.

Entities:  

Mesh:

Year:  2009        PMID: 19232563     DOI: 10.1016/j.ajo.2008.12.015

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  5 in total

1.  Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty.

Authors:  Gavin S Tan; Mingguang He; Donald T Tan; Jodhbir S Mehta
Journal:  BMC Med Imaging       Date:  2012-07-23       Impact factor: 1.930

Review 2.  Applications of Anterior Segment Optical Coherence Tomography in Cornea and Ocular Surface Diseases.

Authors:  Sang Beom Han; Yu-Chi Liu; Karim Mohamed Noriega; Jodhbir S Mehta
Journal:  J Ophthalmol       Date:  2016-09-19       Impact factor: 1.909

3.  Corneal endothelium features in Fuchs' Endothelial Corneal Dystrophy: A preliminary 3D anterior segment optical coherence tomography study.

Authors:  Claudio Iovino; Maurizio Fossarello; Giuseppe Giannaccare; Marco Pellegrini; Mirco Braghiroli; Giuseppe Demarinis; Pietro Emanuele Napoli
Journal:  PLoS One       Date:  2018-11-29       Impact factor: 3.240

4.  Reproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty).

Authors:  Melissa H Y Wong; Annabel Chew; Hla M Htoon; Beng H Lee; Jun Cheng; Jiang Liu; Donald T Tan; Jodhbir S Mehta
Journal:  BMC Med Imaging       Date:  2012-08-01       Impact factor: 1.930

5.  The Use of Digital Microscopy to Compare the Thicknesses of Normal Corneas and Ex Vivo Rejected Corneal Grafts with a Focus on the Descemet's Membrane.

Authors:  Taíse Tognon; Sabrina Bergeron; Christina Mastromonaco; Kleyton Barella; Adriano Pasqualotti; Laura Nunez; Francisco Murta; Luciene Barbosa de Sousa; Mauro Campos; Miguel Noel Nascentes Burnier
Journal:  J Ophthalmol       Date:  2019-11-15       Impact factor: 1.909

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.