Literature DB >> 19231258

A pilot study to evaluate a novel subcutaneous continuous glucose monitoring system in healthy Beagle dogs.

Nadja Affenzeller1, Thomas Benesch, Johann G Thalhammer, Michael Willmann.   

Abstract

Serial blood glucose measurements are currently regarded as the 'gold standard' for evaluating glycaemic control of canine diabetic patients. The aim of this study was to investigate a subcutaneous continuous glucose monitoring system based on microdialysis. Analyses were performed by taking interstitial glucose samples from two different anatomical regions (interscapular region [IR], thoracic region [TR]) in six healthy Beagle dogs during induced hypoglycaemia and hyperglycaemia, the feeding period and a period of stable glucose values. For comparison, plasma glucose concentration was measured simultaneously by a hexokinase-based automated chemistry analyser. The mean absolute differences ranged from 11.7 mg/dL (SD 23.5 mg/dL, TR) to 5.3 mg/dL (SD 19.2 mg/dL, IR) with a correlation of r=0.43-0.92 (P<0.01). Sensitivity for the detection of hypoglycaemia was 85.0% TR and 93.3% IR, and the specificity was 99.5% TR and 99.7% IR, respectively. In a modified Clarke error grid analysis, 99.3% TR and 99.7% IR of the values fell into zone A and B. Collapse of the microdialysis fibre was a recurrent problem although this was easily detectable by fluctuations in system pressure. The microdialysis system reflects physiological as well as induced variations in blood glucose in a valid manner. Copyright 2009 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19231258     DOI: 10.1016/j.tvjl.2009.01.012

Source DB:  PubMed          Journal:  Vet J        ISSN: 1090-0233            Impact factor:   2.688


  4 in total

1.  Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis.

Authors:  Eleonora Malerba; Chiara Cattani; Francesca Del Baldo; Gaia Carotenuto; Sara Corradini; Stefania Golinelli; Ignazio Drudi; Federico Fracassi
Journal:  J Vet Intern Med       Date:  2019-11-14       Impact factor: 3.333

2.  Evaluation of the FreeStyle Libre, a flash glucose monitoring system, in client-owned cats with diabetes mellitus.

Authors:  Marieke Knies; Erik Teske; Hans Kooistra
Journal:  J Feline Med Surg       Date:  2022-06-28       Impact factor: 1.971

3.  Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs.

Authors:  S Corradini; B Pilosio; F Dondi; G Linari; S Testa; F Brugnoli; P Gianella; M Pietra; F Fracassi
Journal:  J Vet Intern Med       Date:  2016-06-18       Impact factor: 3.333

4.  Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus.

Authors:  Francesca Del Baldo; Claudia Canton; Silvia Testa; Harry Swales; Ignazio Drudi; Stefania Golinelli; Federico Fracassi
Journal:  J Vet Intern Med       Date:  2020-10-30       Impact factor: 3.333

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.