Management of gamma nail breakage with bipolar hemi-arthroplasty.

J L H Wee1, S S Sathappan, M S W Yeo, Y P Low.   

Abstract

Gamma nail breakage is an uncommon occurrence that often arises from fatigue failure of the implant, with a reported incidence ranging from 0.2 to 5.7 percent. We report a 73-year-old woman with a three-part intertrochanteric fracture and who presented two years postoperatively with gamma nail failure secondary to fracture non-union. This patient underwent a revision long-stem bipolar hemi-arthroplasty and has been followed-up for 24 months, with good functional and radiological results.

Entities:  

Mesh:

Year:  2009        PMID: 19224071

Source DB:  PubMed          Journal:  Singapore Med J        ISSN: 0037-5675            Impact factor:   1.858


  12 in total

1.  Cemented bipolar hemiarthroplasty with a cerclage cable technique for unstable intertrochanteric hip fractures in elderly patients.

Authors:  Mostafa Abdelkhalek; Ayman M Ali; Mohamed Abdelwahab
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-06-06

Review 2.  Fatigue failure of the cephalomedullary nail: revision options, outcomes and review of the literature.

Authors:  Adam Tucker; Michael Warnock; Sinead McDonald; Laurence Cusick; Andrew P Foster
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-10-17

3.  The challenge of non-union in subtrochanteric fractures with breakage of intramedullary nail: evaluation of outcomes in surgery revision with angled blade plate and allograft bone strut.

Authors:  G Rollo; N Tartaglia; G Falzarano; P Pichierri; A Stasi; A Medici; L Meccariello
Journal:  Eur J Trauma Emerg Surg       Date:  2017-03-03       Impact factor: 3.693

4.  Implant failure caused by non-union of bisphosphonate-associated subtrochanteric femur fracture.

Authors:  Barry James O'Neill; Sven O'hEireamhoin; David I Morrissey; Peter Keogh
Journal:  BMJ Case Rep       Date:  2014-04-03

5.  An innovative technique for removal of a broken intramedullary hip screw.

Authors:  F Runau; B Bloch; T Green
Journal:  Ann R Coll Surg Engl       Date:  2011-05       Impact factor: 1.951

6.  Breakage of a third generation gamma nail: a case report and review of the literature.

Authors:  Takashi Iwakura; Takahiro Niikura; Sang Yang Lee; Yoshitada Sakai; Kotaro Nishida; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Case Rep Orthop       Date:  2013-05-20

7.  Nonunion with breakage of gamma nail and subsequent fracture in the ipsilateral femur.

Authors:  Takahiro Niikura; Sang Yang Lee; Yoshitada Sakai; Kotaro Nishida; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Case Rep Med       Date:  2013-02-21

8.  The variable angle hip fracture nail relative to the gamma 3: a finite element analysis illustrating the same stiffness and fatigue characteristics.

Authors:  Amir Matityahu; Andrew H Schmidt; Alan Grantz; Ben Clawson; Meir Marmor; R Trigg McClellan
Journal:  Adv Orthop       Date:  2013-03-26

9.  Failure of a Rotation Control Gamma 3 Lag Screw Used to Treat a Trochanteric Fracture.

Authors:  Kyungho Choi; Yongtae Kim; Shicheng Zhou; Jihyo Hwang
Journal:  Hip Pelvis       Date:  2018-06-04

10.  Breakage in Two Points of a Short and Undersized "Affixus" Cephalomedullary Nail in a Very Active Elderly Female: A Case Report and Review of the Literature.

Authors:  Giuseppe Rollo; Giuseppe Rinonapoli; Paolo Pichierri; Michele Bisaccia; Auro Caraffa; Luigi Meccariello
Journal:  Case Rep Orthop       Date:  2018-09-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.