Literature DB >> 19221183

A novel imaging technique for fusion of high-quality immobilised MR images of the head and neck with CT scans for radiotherapy target delineation.

G J Webster1, J E Kilgallon, K F Ho, C G Rowbottom, N J Slevin, R I Mackay.   

Abstract

Uncertainty and inconsistency are observed in target volume delineation in the head and neck for radiotherapy treatment planning based only on CT imaging. Alternative modalities such as MRI have previously been incorporated into the delineation process to provide additional anatomical information. This work aims to improve on previous studies by combining good image quality with precise patient immobilisation in order to maintain patient position between scans. MR images were acquired using quadrature coils placed over the head and neck while the patient was immobilised in the treatment position using a five-point thermoplastic shell. The MR image and CT images were automatically fused in the Pinnacle treatment planning system using Syntegra software. Image quality, distortion and accuracy of the image registration using patient anatomy were evaluated. Image quality was found to be superior to that acquired using the body coil, while distortion was < 1.0 mm to a radius of 8.7 cm from the scan centre. Image registration accuracy was found to be 2.2 mm (+/- 0.9 mm) and < 3.0 degrees (n = 6). A novel MRI technique that combines good image quality with patient immobilization has been developed and is now in clinical use. The scan duration of approximately 15 min has been well tolerated by all patients.

Entities:  

Mesh:

Year:  2009        PMID: 19221183     DOI: 10.1259/bjr/50709041

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  7 in total

Review 1.  Functional magnetic resonance imaging techniques and their development for radiation therapy planning and monitoring in the head and neck cancers.

Authors:  Jing Yuan; Gladys Lo; Ann D King
Journal:  Quant Imaging Med Surg       Date:  2016-08

2.  GTV delineation in supraglottic laryngeal carcinoma: interobserver agreement of CT versus CT-MR delineation.

Authors:  Elise Anne Jager; Nicolien Kasperts; Joana Caldas-Magalhaes; Mariëlle E P Philippens; Frank A Pameijer; Chris H J Terhaard; Cornelis P J Raaijmakers
Journal:  Radiat Oncol       Date:  2015-01-23       Impact factor: 3.481

3.  Image Fusion of CT and MR with Sparse Representation in NSST Domain.

Authors:  Chenhui Qiu; Yuanyuan Wang; Huan Zhang; Shunren Xia
Journal:  Comput Math Methods Med       Date:  2017-11-09       Impact factor: 2.238

4.  Prospective analysis of in vivo landmark point-based MRI geometric distortion in head and neck cancer patients scanned in immobilized radiation treatment position: Results of a prospective quality assurance protocol.

Authors: 
Journal:  Clin Transl Radiat Oncol       Date:  2017-10-10

Review 5.  "Après Mois, Le Déluge": Preparing for the Coming Data Flood in the MRI-Guided Radiotherapy Era.

Authors:  Kendall J Kiser; Benjamin D Smith; Jihong Wang; Clifton D Fuller
Journal:  Front Oncol       Date:  2019-09-30       Impact factor: 6.244

6.  Prospective quantitative quality assurance and deformation estimation of MRI-CT image registration in simulation of head and neck radiotherapy patients.

Authors:  Kendall Kiser; Mohamed A M Meheissen; Abdallah S R Mohamed; Mona Kamal; Sweet Ping Ng; Hesham Elhalawani; Amit Jethanandani; Renjie He; Yao Ding; Yousri Rostom; Neamat Hegazy; Houda Bahig; Adam Garden; Stephen Lai; Jack Phan; Gary B Gunn; David Rosenthal; Steven Frank; Kristy K Brock; Jihong Wang; Clifton D Fuller
Journal:  Clin Transl Radiat Oncol       Date:  2019-04-24

7.  Development of a dedicated phantom for multi-target single-isocentre stereotactic radiosurgery end to end testing.

Authors:  Joel Poder; Ryan Brown; Harry Porter; Rashmi Gupta; Anna Ralston
Journal:  J Appl Clin Med Phys       Date:  2018-09-16       Impact factor: 2.102

  7 in total