Reliability and validity of the instrumental assessment of implant stability in dry human mandibles.

J E I G Brouwers1, F Lobbezoo, C M Visscher, D Wismeijer, M Naeije.   

Abstract

The aim of this study was to determine the intra- and interobserver reliability and validity of the instrumental assessment of primary dental implant stability, using resonance frequency analysis (RFA). Sixteen tapered implants and 16 cylindrical implants were installed in eight unfixed dry human mandibles (Cawood classification IV/V). Implant stability quotients (ISQ; the outcome variable of RFA) and peak removal torque were determined. Both the intra-observer reliability and the interobserver reliability of the RFA measurements were fair-to-good, while no significant correlations between the ISQ values and removal torque were found. The removal torque of the cylindrical implants was higher than that of the tapered implants. The smallest detectable difference was almost nine ISQ units. Within the limitations of the present dry cadaver study, it was concluded that (i) primary dental implant stability can be assessed reliably with RFA measurements, (ii) the concurrent validity between RFA measurements and removal torque is poor, (iii) cylindrical implants may be more stable than tapered ones and (iv) two subsequent readings of RFA measurements need to differ at least nine ISQ units before the difference between the two measurements can be considered statistically significant. More research is needed to see whether these conclusions can be extrapolated to the clinical situation, including the assessment of implants during function (secondary stability).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19220717     DOI: 10.1111/j.1365-2842.2009.01944.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  6 in total

1.  Intra- and inter-operator concordance of the resonance frequency analysis. A cross-sectional and prospective clinical study.

Authors:  Raquel Antequera-Diaz; Maria-Pilar Quesada-García; Cristina Vallecillo; Marta Vallecillo-Rivas; Esther Muñoz-Soto; Maria-Victoria Olmedo-Gaya
Journal:  Clin Oral Investig       Date:  2022-07-08       Impact factor: 3.573

2.  Analysis of primary stability of dental implants inserted in different substrates using the pullout test and insertion torque.

Authors:  Nathalia Ferraz Oliscovicz; Antônio Carlos Shimano; Elcio Marcantonio Junior; César Penazzo Lepri; Andréa Candido Dos Reis
Journal:  Int J Dent       Date:  2013-01-22

3.  Resonance frequency analysis-reliability in third generation instruments: Osstell mentor®.

Authors:  Mariano Herrero-Climent; Matteo Albertini; Jose-Vicente Rios-Santos; Pedro Lázaro-Calvo; Ana Fernández-Palacín; Pedro Bullon
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-09-01

4.  Assessment of Osstell ISQ's reliability for implant stability measurement: a cross-sectional clinical study.

Authors:  Mariano Herrero-Climent; Rocio Santos-García; Reyes Jaramillo-Santos; Manuel-Maria Romero-Ruiz; Ana Fernández-Palacin; Pedro Lázaro-Calvo; Pedro Bullón; Jose-Vicente Ríos-Santos
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-11-01

5.  Stability, Survival, and Tolerability of an Auditory Osseointegrated Implant for Bone Conduction Hearing: Long-Term Follow-Up of a Randomized Controlled Trial.

Authors:  Christine A den Besten; Joacim Stalfors; Stina Wigren; Johan Ivarsson Blechert; Mark Flynn; Måns Eeg-Olofsson; Rohini Aggarwal; Kevin Green; Rik C Nelissen; Emmanuel A M Mylanus; Myrthe K S Hol
Journal:  Otol Neurotol       Date:  2016-09       Impact factor: 2.311

6.  Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study.

Authors:  Vinod Bandela; Bharathi Munagapati; Jayashree Komala; Ram B Basany; Santosh R Patil; Saraswathi Kanaparthi
Journal:  J Int Soc Prev Community Dent       Date:  2020-09-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.