INTRODUCTION: For patients undergoing catheter ablation of atrial fibrillation (AF), left atrial size is a predictor of recurrence of AF during follow-up. For this reason, major clinical trials have used a left atrial diameter (LAD) of more than 5.0 or 5.5 cm, assessed by echocardiography, as an exclusion criterion for patients deemed candidates for ablation of AF. However, whether LAD accurately reflects true left atrial size has not been systematically investigated. Therefore, the purpose of this study was to test the hypothesis that LAD, measured by echocardiography, accurately correlates to left atrial volume measured by computed tomography (CT). METHODS AND
RESULTS: We included 50 patients (mean age 56 +/- 12 years, five female) with symptomatic AF (40% paroxysmal, 60% persistent), referred for catheter ablation. In each patient, transthoracic echocardiography was performed. Additionally, all patients underwent CT using a 64-slice CT scanner. Left atrial volume was calculated by manually tracing left atrial area on each CT cross-sectional image. Patients had a mean LAD measured by echocardiography of 4.5 +/- 0.7 cm, ranging from 2.9 to 5.7 cm. Left atrial volume measured by CT ranged from 67 mL to 270 mL with a mean value of 146 +/- 49 mL. A poor correlation was noted between LAD and left atrial volume, r = 0.49 (P < 0.001).
CONCLUSION: LAD measured by echocardiography correlates poorly with left atrial volume measured by CT in patients with AF. As a result, selecting patients with AF for treatment with catheter ablation should not be based on an echocardiographic-derived LAD alone.

Entities:  

Mesh:

Year:  2009        PMID: 19220573     DOI: 10.1111/j.1540-8167.2008.01310.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  26 in total

1.  A simplified method to determine left atrial volume and transport function using multi-slice computed tomography in patients with atrial fibrillation: comparison with transthoracic echocardiography.

Authors:  Seung Yong Shin; Hwan Seok Yong; Jin Oh Na; Cheol Ung Choi; Seong Hwan Kim; Jin Won Kim; Eung Ju Kim; Seung-Woon Rha; Chang Gyu Park; Hong Seog Seo; Dong Joo Oh; Young-Hoon Kim; Hong Euy Lim
Journal:  Int J Cardiovasc Imaging       Date:  2011-07-06       Impact factor: 2.357

Review 2.  [Cardiac computed tomography and ablation of atrial fibrillation].

Authors:  Martin Schmidt; F Straube; U Ebersberger; U Dorwarth; M Wankerl; J Krieg; E Hoffmann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2012-12-05

3.  Can we change the operative criteria for the MAZE procedure combined with valve surgery in the era of radiofrequency devices?

Authors:  Suguru Kubota; Hiroshi Sugiki; Satoru Wakasa; Tomonori Ooka; Tsuyoshi Tachibana; Shigeyuki Sasaki; Yoshiro Matsui
Journal:  Gen Thorac Cardiovasc Surg       Date:  2011-06-15

Review 4.  2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design.

Authors:  Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; Jose Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber
Journal:  J Interv Card Electrophysiol       Date:  2012-03       Impact factor: 1.900

5.  Characteristic changes of volume and three-dimensional structure of the left atrium in different forms of atrial fibrillation: predictive value after ablative treatment.

Authors:  Sotirios Nedios; Min Tang; Mattias Roser; Natalia Solowjowa; Jin-Hong Gerds-Li; Eckart Fleck; Charalampos Kriatselis
Journal:  J Interv Card Electrophysiol       Date:  2011-06-11       Impact factor: 1.900

Review 6.  Predictors of Recurrence After Radiofrequency Ablation of Persistent Atrial Fibrillation.

Authors:  Miki Yokokawa; Hakan Oral; Aman Chugh
Journal:  J Atr Fibrillation       Date:  2012-10-06

Review 7.  The Role of Atrial Structural Remodeling in Atrial Fibrillation Ablation:An Imaging Point of View for Predicting Recurrence.

Authors:  Yasushi Akutsu; Kaoru Tanno; Youichi Kobayashi
Journal:  J Atr Fibrillation       Date:  2012-08-20

8.  Left atrial pressure as predictor for recurrence of atrial fibrillation after pulmonary vein isolation.

Authors:  Markus Linhart; Thorsten Lewalter; Erica L Mittmann-Braun; Nicole C Karbach; René P Andrié; Christoph Hammerstingl; Rolf Fimmers; Jens Kreuz; Georg Nickenig; Jan W Schrickel; Lars M Lickfett
Journal:  J Interv Card Electrophysiol       Date:  2013-06-23       Impact factor: 1.900

9.  Impact of catheter ablation with remote magnetic navigation on procedural outcomes in patients with persistent and long-standing persistent atrial fibrillation.

Authors:  Qi Jin; Steen Pehrson; Peter Karl Jacobsen; Xu Chen
Journal:  J Interv Card Electrophysiol       Date:  2015-07-28       Impact factor: 1.900

Review 10.  Atrial remodeling and atrial fibrillation recurrence after catheter ablation : Past, present, and future developments.

Authors:  Sotirios Nedios; Frank Lindemann; Jordi Heijman; Harry J G M Crijns; Andreas Bollmann; Gerhard Hindricks
Journal:  Herz       Date:  2021-07-05       Impact factor: 1.443

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.