In vitro antibacterial and cytotoxicity assessments of an orthodontic bonding agent containing benzalkonium chloride.

Kayo Saito1, Tohru Hayakawa, Rihito Kawabata, Daijiro Meguro, Kazutaka Kasai.   

Abstract

OBJECTIVE: To assess the antibacterial activity and cytotoxicity of an orthodontic bonding material containing an antibacterial agent.
MATERIALS AND METHODS: Superbond C&B (4-methacryloxyethyl trimellitate anhydride/methyl methacrylate-tri-n-butyl borane [4-META/MMA-TBB]) resin was mixed with benzalkonium chloride (BAC) to obtain final BAC concentrations of 0.25%, 0.75%, 1.25%, 1.75%, 2.5%, and 5.0% (wt/ wt). Antibacterial activity against Streptococcus mutans and Streptococcus sobrinus was evaluated by soaking the BAC-resin in distilled water at 37 degrees C for periods of 30, 90, and 180 days. Antibacterial activity of the BAC-resin was measured by the disk diffusion method, and the inhibition zone around each sample was measured and recorded. For evaluation of cytotoxicity, BAC-resin samples were put into cell culture inserts placed above human gingival cells and were incubated at 37 degrees C for 1, 3, and 6 days. Cytotoxicity was assessed with a tetrazolium bromide reduction assay.
RESULTS: The antibacterial activity of BAC-incorporated resin samples decreased significantly after immersion in water for 180 days, regardless of BAC concentration. The antibacterial activity of nonimmersed resin containing 0.25% or 1.75% BAC was comparable with that of 5.0% BAC-resin immersed for 180 days. In cytotoxicity tests, most cells died when exposed to resins containing 1.75%, 2.5%, and 5% BAC. No difference was observed between resins containing 0.25% and 0.75% BAC at 1, 3, and 6 days of culture.
CONCLUSIONS: The addition of BAC to 4-META/MMA-TBB resin confers an antibacterial effect even after immersion in water, and 4-META/MMA-TBB resin containing 0.25% to 0.75% BAC has no significant cytotoxic effect.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19216609     DOI: 10.2319/120907-578.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  2 in total

1.  Antimicrobial efficacy and mechanical properties of BAC-modified hard and soft denture liners.

Authors:  Pinar Altinci; Murat Mutluay; Eva Söderling; Arzu Tezvergil-Mutluay
Journal:  Odontology       Date:  2017-03-20       Impact factor: 2.634

Review 2.  Should local drug delivery systems be used in dentistry?

Authors:  Joana Vieira Costa; Jaime Portugal; Cristina Bettencourt Neves; Ana F Bettencourt
Journal:  Drug Deliv Transl Res       Date:  2021-09-20       Impact factor: 4.617

  2 in total