Effect of implant support on distal-extension removable partial dentures: in vivo assessment.

Chikahiro Ohkubo1, Mariko Kobayashi, Yasunori Suzuki, Toshio Hosoi.   

Abstract

PURPOSE: The use of a limited number of implants for support of a removable partial denture (RPD) changes a Kennedy Class I or II situation to that of a Class III. This in vivo pilot study evaluated implant-supported distal-extension removable partial dentures (RPD) in 5 partially edentulous patients.
MATERIALS AND METHODS: Two implants (Brånemark TU MK III, Nobel Biocare) were placed in a mandibular Kennedy Class I arch. To fabricate an implant-supported RPD (ISRPD), a conventional RPD base was fitted to the healing abutment with autopolymerizing acrylic resin (Uni-fast II, GC) to support the posterior aspect of the RPD. By changing the healing abutment to a healing cap, there was no connection between the denture base and implant, and the ISRPD became a conventional RPD (CRPD). Using a crossover study design, the masticatory movements (mandibular movements during mastication) of both dentures were measured using a commercially available tracking device (BioPACK, Bioresearch, Japan). The occlusal force and contact area were also measured using pressure-sensitive sheets and an image scanner (T-scan system). Using a visual analog scale (VAS), the 4 criteria of comfort, chewing, retention, and stability were evaluated. All the data obtained were analyzed using Wilcoxen signed rank tests (alpha = .05).
RESULTS: There were no significant differences (P > .05) in masticatory movements between the ISRPD and the CRPD (5 patients: 4 women, 1 man). However, the ISRPD had significantly greater force and greater area than the CRPD (P = .043). The center of occlusal force of the ISRPD tended to move more distally compared to the CRPD. All the patients preferred the ISRPD for comfort, chewing, retention, and stability.
CONCLUSIONS: One implant per edentulous area and a simple attachment technique yielded a stable distal extension RPD.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19216279

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  17 in total

1.  Removable partial denture supported by implants with prefabricated telescopic abutments - a case report.

Authors:  Lalit Kumar; Komal Sehgal
Journal:  J Clin Diagn Res       Date:  2014-06-20

2.  The Use of Implants to Improve Removable Partial Denture Function.

Authors:  Marcele Jardim Pimentel; Juan Pablo Arréllaga; Ataís Bacchi; Altair A Del Bel Cury
Journal:  J Indian Prosthodont Soc       Date:  2013-08-03

3.  Distal extension mandibular removable partial denture with implant support.

Authors:  Canan Bural; Begum Buzbas; Sebnem Ozatik; Gulsen Bayraktar; Yusuf Emes
Journal:  Eur J Dent       Date:  2016 Oct-Dec

4.  A Clinical Retrospective Study of Distal Extension Removable Partial Denture with Implant Surveyed Bridge or Stud Type Attachment.

Authors:  Eun-Bin Bae; Seong-Jong Kim; Jae-Won Choi; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; So-Hyoun Lee; Jung-Bo Huh
Journal:  Biomed Res Int       Date:  2017-04-09       Impact factor: 3.411

5.  Effect of the Location of Dental Mini-Implants on Strain Distribution under Mandibular Kennedy Class I Implant-Retained Removable Partial Dentures.

Authors:  Pimduen Rungsiyakull; Kallaya Kujarearntaworn; Pathawee Khongkhunthian; Michael Swain; Chaiy Rungsiyakull
Journal:  Int J Dent       Date:  2021-05-04

6.  Strain Distribution in a Kennedy Class I Implant Assisted Removable Partial Denture under Various Loading Conditions.

Authors:  Reza Shahmiri; John M Aarts; Vincent Bennani; Raj Das; Michael V Swain
Journal:  Int J Dent       Date:  2013-04-30

7.  Short strategic implants for mandibular removable partial dentures: One-year results from a pilot randomized crossover abutment type study.

Authors:  Norbert Enkling; Joël Nauli; Dominik Kraus; Julia Gabriela Wittneben; Martin Schimmel; Samir Abou-Ayash
Journal:  Clin Oral Implants Res       Date:  2021-08-25       Impact factor: 5.021

8.  Periodontal ligament influence on the stress distribution in a removable partial denture supported by implant: a finite element analysis.

Authors:  Carlos Marcelo Archangelo; Eduardo Passos Rocha; João Antônio Pereira; Manoel Martin Junior; Rodolfo Bruniera Anchieta; Amilcar Chagas Freitas Júnior
Journal:  J Appl Oral Sci       Date:  2012 May-Jun       Impact factor: 2.698

9.  Effects of Length and Inclination of Implants on Terminal Abutment Teeth and Implants in Mandibular CL1 Removable Partial Denture Assessed by Three-Dimensional Finite Element Analysis.

Authors:  Amir Fayaz; Alahyar Geramy; Yeganeh Memari; Zahra Rahmani
Journal:  J Dent (Tehran)       Date:  2015-10

Review 10.  Implant treatment in ultra-aged society.

Authors:  Yuji Sato; Noboru Kitagawa; Akio Isobe
Journal:  Jpn Dent Sci Rev       Date:  2018-01-10