Abstract

BACKGROUND: The preoperative range of motion is an important factor that influences the range of motion after total knee arthroplasty. Because the length and tightness of the extensor mechanism are extracapsular elements with an influence on knee flexion, it is reasonable to assume that the tension of the knee extensor mechanism during surgery has a considerable impact on the postoperative range of motion. The purpose of this study was to determine the influence of the tightness of knee extensor mechanism on postoperative knee flexion.
METHODS: In 18 knees undergoing posterior-stabilized type total knee arthroplasty, we measured the longitudinal strain on the patellar tendon with all the components in position during passive knee flexion up to 135 degrees . The patellar tendon strains measured during surgery were compared with the preoperative maximum knee flexion angle and postoperative maximum knee flexion angle at 1 year.
RESULTS: There was a significant inverse correlation between the patellar tendon strain during surgery at 60 degrees (r = -0.54, P < 0.05), 90 degrees (r = -0.55, P < 0.05), or 135 degrees of flexion (r = -0.65, P < 0.05) and postoperative knee flexion.
CONCLUSIONS: The results indicated that subjects with high intraoperative patellar tendon strain during passive flexion of the knee had more restricted postoperative knee flexion. Therefore, the tightness of the knee extensor mechanism measured at total knee arthroplasty is a good predictor of maximum postoperative range of flexion.

Mesh:

Year:  2009        PMID: 19214688     DOI: 10.1007/s00776-008-1286-7

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  2 in total

1.  Patellar tendon buckling in post-operative total knee arthroplasty patients is more prominent than in healthy controls.

Authors:  Laura Chernak Slane; Félix Dandois; Stijn Bogaerts; Lennart Scheys; Hilde Vandenneucker
Journal:  Med Eng Phys       Date:  2019-06-18       Impact factor: 2.242

Review 2.  Three-dimensional motion analysis and its application in total knee arthroplasty: what we know, and what we should analyze.

Authors:  Yoshio Koga
Journal:  J Orthop Sci       Date:  2015-01-22       Impact factor: 1.601