Literature DB >> 19213608

Favorable toxicity and biochemical control using real-time inverse optimization technique for prostate brachytherapy.

Adam Raben1, Kyle E Rusthoven, Abrihup Sarkar, Andrew Glick, Bruce Benge, Dayee Jacobs, David Raben.   

Abstract

PURPOSE: Favorable dosimetric results have been reported using intraoperative inverse optimization (IO) for permanent prostate brachytherapy. The clinical implications of these improvements in dosimetry are unclear. We review toxicity and early biochemical outcomes for patients implanted using IO technique. METHODS AND MATERIALS: Between 2001 and 2007, 165 patients received permanent prostate implants using real-time IO and had >/=3 months of followup. Dose constraints for inverse planning were: the prostate volume receiving 100% of the prescription dose [prostate V(100)] was >95%; the dose received by 90% of the gland [prostate D(90)] was within the 140-180 by dose range; the volume of urethra receiving 150% of the prescription dose [urethra V(150)] was <30%; and the volume of rectal wall receiving 110% of the prescription dose [rectal V(110)] was <1.0 cc. Toxicity was prospectively scored using the Radiation Therapy Oncology Group toxicity scale and the International Prostate Symptom Score questionnaire. Biochemical control was determined using the nadir + 2 ng/mL definition.
RESULTS: Mean followup was 30 months (range, 6-63 months). Risk classification was low risk in 89% and intermediate risk in 11%. Iodine-125 sources were used for 161 implants and palladium-103 sources for four implants. The median number of seeds and total activity implanted were 61 and 999 MBq, respectively, for a median prostate volume of 33.6 cc. Late GU and GI morbidity was uncommon. Among patients with at least 24 months followup, 16% had persistent Grade 2-3 urinary morbidity. Grade 2 rectal bleeding occurred in 1 patient (0.6%). Biochemical failure has occurred in only 4 patients at last followup.
CONCLUSIONS: IO technique for prostate brachytherapy is associated with low rates of late morbidity and excellent early biochemical control. Additionally, the number of seeds and total implanted activity required to achieve a high-quality implant are lower compared with historical controls.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19213608     DOI: 10.1016/j.brachy.2008.12.004

Source DB:  PubMed          Journal:  Brachytherapy        ISSN: 1538-4721            Impact factor:   2.362


  4 in total

1.  Results from the Quality Research in Radiation Oncology (QRRO) survey: Evaluation of dosimetric outcomes for low-dose-rate prostate brachytherapy.

Authors:  Michael J Zelefsky; Gil'ad N Cohen; Walter R Bosch; Lisa Morikawa; Najma Khalid; Cheryl L Crozier; W Robert Lee; Anthony Zietman; Jean Owen; J Frank Wilson; Phillip M Devlin
Journal:  Brachytherapy       Date:  2012-07-21       Impact factor: 2.362

2.  Real-time intraoperative computed tomography assessment of quality of permanent interstitial seed implantation for prostate cancer.

Authors:  Michael J Zelefsky; Mick Worman; Gilad N Cohen; Xin Pei; Marisa Kollmeier; Josh Yamada; Brett Cox; Zhigang Zhang; Eva Bieniek; Lawrence Dauer; Marco Zaider
Journal:  Urology       Date:  2010-11       Impact factor: 2.649

3.  Evaluation of dosimetry and excess seeds in permanent brachytherapy using a modified hybrid method: a single-institution experience.

Authors:  Kana Kobayashi; Koji Okihara; Tsuyoshi Iwata; Norihiro Aibe; Naohiro Kodani; Takuji Tsubokura; Kazumi Kamoi; Tsuneharu Miki; Hideya Yamazaki
Journal:  J Radiat Res       Date:  2013-01-04       Impact factor: 2.724

4.  Narrow safety range of intraoperative rectal irradiation exposure volume for avoiding bleeding after seed implant brachytherapy.

Authors:  Ryuji Nakamura; Koyo Kikuchi; Susumu Tanji; Tomonori Yabuuchi; Ikuko Uwano; Satoshi Yamaguchi; Hisanori Ariga; Tomoaki Fujioka
Journal:  Radiat Oncol       Date:  2012-01-31       Impact factor: 3.481

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.