Literature DB >> 19212503

Microtensile and microshear bond strength of an antibacterial self-etching system to primary tooth dentin.

Sibel Yildirim1, Gül Tosun, Alp Erdin Koyutürk, Yagmur Sener, Abdulkadir Sengün, Füsun Ozer, Satoshi Imazato.   

Abstract

OBJECTIVES: The aim of this study was to test the hypothesis that the bonding ability of antibacterial bonding system to primary dentin was not different from the parental material which did not contain any antibacterial component.
METHODS: Extracted human non-carious primary molars were ground to expose the coronal dentin, and then randomly divided into two experimental groups: treatment with Clearfil Protect Bond or with Clearfil SE Bond (Kuraray Medical Inc.). Composite-dentin sticks with a cross-sectional area of approximately 0.90 mm(2) were prepared and subsequently subjected to microtensile bond strength (muTBS) and microshear bond strength (muSBS) tests. For the muTBS tests, specimens were attached to an Instron testing machine with a cyanoacrylate adhesive. For muSBS testing, the sticks were mechanically fixed to the muSBS testing apparatus. The bonds were stressed in shear or tension at a crosshead speed of 1mm/min until failure occurred. Resin-dentin interfaces produced by each system were examined using SEM. The data were analyzed with Mann-Whitney's U test.
RESULTS: The muTBS and muSBS of Clearfil Protect Bond were 30.69+/-9.71 and 9.94+/-3.78 MPa, respectively. Clearfil SE Bond showed significantly greater values of 37.31+/-9.57 and 12.83+/-3.15 MPa, respectively. SEM analysis demonstrated similar micro-morphological features including the thickness of the hybrid layer for both materials.
CONCLUSIONS: It was showed that antibacterial self-etching system Clearfil Protect Bond showed lower bond strength values compared to primary dentin than that of to Clearfil SE Bond on primary dentin. (Eur J Dent 2008;2:11-17).

Entities:  

Keywords:  Antibacterial bonding system; Microshear bond strength; Microtensile bond strength; Primary tooth dentin

Year:  2008        PMID: 19212503      PMCID: PMC2633148     

Source DB:  PubMed          Journal:  Eur J Dent


INTRODUCTION

Based on the principles of minimal invasive dentistry, much attention has recently been focused on the least invasive method for caries treatment. However, it is possible that some active bacteria remain after minimal removal of the effected dentin by leaving affected dentin. It is well known that residual bacteria in the prepared cavity can induce recurrent caries and damage to the pulp. Therefore, if the materials applied after cavity preparation possesses antibacterial activity, any indistinct bacterial conditions remaining in the cavity might be overcome, thus contributing to successful restoration. In addition, bacterial leakage through the gap between the restorative material and cavity wall is the main cause of hypersensitivity.1,2 As one solution to these problems, adhesive systems that exert antibacterial effects have been highlighted.3 Dentin adhesives are now widely used in clinical dentistry, and improved or new versions, which claim to offer advantages over their predecessors, are constantly being introduced. Self-etching adhesive systems are beneficial for pediatric dentistry practice as well as treatment of adult patients, because the bonding procedures are simplified and technique sensitivity is reduced. Imazato et al4,5 reported that incorporation of the antibacterial monomer 12-methacryloyloxydodecylpyridinium bromide (MDPB) to self-etching primers is an effective method for providing antibacterial activity before and after polymerization. MDP-based primer containing MDPB has been suggested to be useful for both eliminating residual bacteria in the prepared dentinal cavity6,7 and inhibiting invading bacteria at the resin-dentin interface after placement of the restoration. Although the adhesive property of this new system to primary enamel has been investigated,8 little is known about its bonding ability to dentin of primary teeth. This study investigated the bonding performance of the MDPB-containing antibacterial self-etching system to primary teeth dentin by means of microtensile/microshear test methods and morphological observations of the bonding interface. The hypothesis that the incorporation of MDPB would not alter the bonding characteristics of the adhesive resin was tested.

MATERIALS AND METHODS

Specimen preparations

Ten extracted human non-carious primary molars were used. Teeth were stored at 4°C in saline solution containing 0.1% thymol and used within three months following extraction. The occlusal surfaces of the teeth were cut just below the dentino-enamel junction to expose a flat area of dentin using a low-speed diamond saw (Isomet, Buehler Ltd, Lake Bluff, IL, USA) under water-cooling. The dentin surfaces were hand-polished with 600grit silicon carbide abrasive paper under running water to create a uniform surface and smear layer. Then, the teeth were randomly divided into two groups for treatment with either Clearfil Protect Bond (PB, Kuraray Medical Inc., Okayama, Japan) or Clearfil SE Bond (SE, Kuraray Medical Inc., Okayama, Japan) (Table 1). PB consists of a self-etching primer containing the antibacterial monomer MDPB and a fluoride-releasing bonding resin. Following application of each adhesive according to the manufacturer’s instructions, the surface was built up with three layers of resin composite (Clearfil AP-X, Kuraray Medical Inc., Okayama, Japan) to a height of 5mm with light curing of each increment for 40sec. The samples were then stored in water at 37°C for 24h.
Table 1

Manufacturers, components and application procedures of the adhesive systems used in this study.

Adhesive systemsComponentsCompositionsProcedures
Clearfil Protect Bond (Kuraray Medical Inc., Japan)Antibacterial primer Fluoride releasing bonding resinMDPB, MDP, HEMA, water, hydrophilic, dimethacrylate, photoinitiators MDP, HEMA, Bis-GMA, silinated colloidal silica, surface treated NaFa (20 sec), b, c, d (10 sec)

Clearfil SE Bond (Kuraray Medical Inc., Japan)Primer Bonding resinMDP, HEMA, water, hydrophilic dimeracyrlate MDP, Bis-GMA, HEMA, hydrophilic dimethacrylate, silinated colloidal silicaa (20 sec), b, c, d (10 sec)

a:apply primer, b:dry gently, c:apply adhesive, d:light cure

Bond strength tests

The roots of the teeth were removed approximately 2mm below the cementoenamel junction then the remaining dentin-resin composite blocks were vertically sectioned into 1×1mm sticks by means of a low-speed diamond saw under watercooling according to the technique for the non-trimming version of the microtensile bond test reported by Sano et al.9 Each sample had a cross-sectional area of 0.90±0.05mm2. For the microtensile bond strength (μTBS) tests, specimens were attached to an Instron testing machine (Dillon, Tronix Inc. MN 56031-1000 Instron Drive Fairmont, USA) with a cyanoacrylate adhesive. Tensile forces were applied to the composite dentine attachment line at a crosshead speed of 1mm/min until failure occurred. For determination of microshear bond strength (μSBS), samples were mechanically fixed to the microshear bond testing apparatus (Figure 1), and forces were applied to the composite-dentin bonded line at a cross head speed of 1mm/min. The bond strengths were expressed in MPa after measuring the cross-sectional area at the site of fracture with digital calipers (Mitutoyo, Tokyo, Japan). Fifteen specimens were tested for each group.
Figure 1

Microshear bond testing apparatus

Fracture analysis

After the μTBS and μSBS tests, the fractured surfaces were examined using a stereomicroscope (Olympus SZ 4045 TRPR, Tokyo, Japan) at ×20 magnification. Failure modes were categorized into one of three types: adhesive failure, if less than 20% of the resin remained on the tooth surface; cohesive failure, if more than 80% of the resin remained on the tooth surface; or mixed failure, if certain areas exhibited cohesive fracture while other areas exhibited adhesive fracture.

Scanning electron microscopy (SEM) evaluation

Two additional primary teeth were used to evaluate the morphology of the interface between the resin composite and dentin by SEM. After the composite was bonded to the PB or SE-treated dentin surface, the tooth was sectioned in two parallel to its long axis using a low speed diamond saw. The cut surfaces were ground with silicon carbide abrasive paper after being fixed in 10% formaldehyde solution for 24h, and highly polished with a diamond paste (Struers, Copenhagen, Denmark). Then, the specimens were immersed in 10% phosphoric acid solution for 3–5 sec. Following 15 sec rinsing with distilled water, the specimens were subjected to 30sec treatment with 5% sodium hypochlorite solution, and rinsed thoroughly with distilled water. After drying at room temperature (27° C), the specimens were coated with Polaron Sc500 Sputter Coater (VG Microtech Inc., Tokyo, Japan) and examined under SEM (JSM-5600, JEOL, Tokyo, Japan) at an accelerating voltage of 20keV.

Statistical analysis

The test for the homogeneity of variances revealed that the bond strength values were not distributed homogeneously (P<.05), thus, the bond strength and fracture mode results were statistically analyzed by Mann-Whitney’s U test at a confidence level of 95%.

RESULTS

Bond strength

The results of μTBS and μSBS tests are shown in Table 2. Both materials exhibited μTBS greater than 30MPa, but the bond strengths of SE were significantly higher than those of PB (P<.05).
Table 2

The microtensile (μTBS) and microshear bond strength (μSBS) values in MPa of each adhesive system to primary dentin.

PB(Clearfil Protect Bond)SE(Clearfil SE Bond)
μTBS(MPa)Mean ±SD30.69 ±9.71a37.31±9.57b
Median33.9541.57

μSBS(MPa)Mean±SD9.94±3.78c12.83±3.15d
Median12.439

Statistically significant differences were observed between groups with different superscript letter(P<.05)

The modes of failure for each group are shown in Table 3. Failures were predominantly adhesive or cohesive in nature; mixed failures were not recorded in any specimen. With the μTBS tests, all PB specimens demonstrated adhesive failure, while 66.7% adhesive and 33.3% cohesive failure were observed for SE. Adhesive failure occurred in 14 PB specimens (93.3%), but the SE specimens demonstrated 53.3% adhesive and 46.7% cohesive failure for the μSBS tests. The type of dentine cohesive was not observed.
Table 3

The number and percentage of specimens categorized into the three fracture modes.

Adhesive(%)Cohesive(%)Mix(%)
PBμTBS test15(100)00
μSBS test14(93.3)1(6.7)0

SEμTBS test10(66.7)5(33.3)0
μSBS test8(53.3)7(46.7)0

SEM observations

Figures 2 and 3 indicate the resin-dentin interface produced by each adhesive system. The bonded interfaces of both systems presented similar micro-morphological features including a resin infiltration layer (hybrid layer) and resin tag formation. The thickness of the hybrid layer was approximately 1μm and penetration of many resin tags more than 4μm in length was observed.
Figure 2

SEM illustrating the resin-dentin interface of ABF. AR= Adhesive Resin; CR= Composite Resin; RT= Resin Tag; asterisk= Lateral Branches; between the black arrows= Hybrid layer

Figure 3

SEM illustrating the resin-dentin interface of Clearfil SE Bond. AR= Adhesive Resin; CR= Resin Composite; RT= Resin Tag; asterisks= Lateral Branches; between the white arrows=Hybrid layer

DISCUSSION

Microtensile bond test, developed by Sano et al9 utilize a small bonding interface in the order of 1mm2 and are commonly used to compare the adhesive abilities of different adhesive systems. In addition, the microshear bond test was recently suggested as being a useful method for investigating adhesive abilities.10 Therefore, in this study, the bond strengths of PB and SE to primary teeth dentin were compared using these two methods. Our results indicated that the μTBS and μSBS of PB were significantly less than those of SE, which means incorporation of the antibacterial monomer MDPB to the self-etching primer cause a decrease in bond strength to primary teeth dentin. Kameyama et al11 reported that the PB system showed significantly lower bond strengths than SE to bovine dentin, and concluded that this decrease might have been due to the bonding resin of PB rather than the MDPB-containing self-etching primer. The bonding resin of PB contains sodium fluoride, which gives it a fluoride-releasing function, and its viscosity is slightly greater than the bonding resin of SE.12 Imazato et al13 suggested that the viscosity of adhesive resin was increased by the addition of a large amount of MDPB, the concentration of MDPB incorporation was set at 2.5% as the maximum value. While the handling characteristics were not hampered, they speculate that a slight decrease, although not significant, of bond strength with experimental adhesive might be derived from inferior infiltration of the resin into the primed dentin due to a slight increase in the viscosity. We used thymol as storage medium and this might cause lower bond strengths as it has been shown that phenolic compounds such as thymol inhibit the polymerization of methyl methacrylate by reacting with free radicals.14 As it is known, the bonding mechanism of adhesive systems to dentin is micromechanical, essentially based on infiltration of resin components into the etched dentin surface and subsequent formation of a resin infiltration layer (hybrid layer), resin tags, and adhesive lateral branches.15 In addition, self-etch adhesive systems partially demineralise the dentin surface and simultaneously infiltrate resin monomer into the dentin matrix, resulting in the creation of a hybrid layer containing scattered apatite crystals. The acidic functional monomer present in the self etching primer may interact with Ca ions to form insoluble Ca salts.16 The crystalline characteristic of the dentin matrix may affect the bond strength of self-etch adhesive systems. The presence of solubilised Ca within the partially demineralised zone may promote chemical interactions with acidic functional monomers.17 SEM observations indicated almost similar interfacial morphology for both adhesive systems including the thickness of the hybrid layer and length of the resin tags. Since in-vitro tags are known to be longer than the ones produced in-vivo, observed long tags in the study were not expected to add to the bond strength.18 Under conventional tensile and shear bond tests, stressed specimens often demonstrate cohesive failure in the dentin or resin material. On the other hand, cohesive fractures are not observed clinically with adhesive restorations.9 The number of cohesive fractures in dentin was significantly reduced when a microtensile bond test was performed.9 Pashley et al19 suggested that the small size of the specimens led to a more favourable stress distribution and thus failure, which more closely represented the true ultimate strengths. Nevertheless, De Munck et al20 and Doi et al21 reported that adhesive failure seldom occurred in μTBS tests of PB using permanent dentin. This fact indicates the strong bonding characteristics of PB to permanent dentin. On the contrary, PB demonstrated adhesive failure in almost all the specimens following microtensile and microshear testing in this study. In the present μTBS tests, the specimens were placed passively in a jig to ensure that there was no preloading stress, and with μSBS testing, the shear force was applied by a stubby edge blade. With permanent teeth, a wide variety of μTBS results have been reported for SE,22,23 possibly due to differences in the methodology such as the test apparatus.24 For μSBS testing, many different configurations including wire loops, points or knife edges have been reported.10,25 Therefore, although precise comparisons of our results with those of previous studies are not possible, we found that the bond strengths of PB and SE to dentin of primary teeth were generally lower compared with those reported for permanent dentin.20,21,26 Several differences in chemical composition or micromorphology exist between dentin of primary and permanent teeth.27 Peritubular dentin of primary teeth is 2–5 times thicker than that of permanent teeth28 and permanent dentin is more highly mineralized than primary teeth.29 Micromorphological analysis of primary teeth showed a lower density and diameter of dentinal tubules, therefore the permeability of primary dentin is less than that of permanent dentin.30 Olmez et al31 reported that the hybrid layer produced in primary teeth was thicker than in permanent teeth. It was concluded by Burrow et al32 that the major reason for a decrease in bond strengths in primary teeth is the greater water content in dentin approximating the pulp, not variations in the structure of surface area of intertubular dentin. These differences between primary and permanent teeth are thought to be responsible for lower bond strength.29,30 In the present study, although the same materials were used, the microshear tests showed lower values than the microtensile tests. Kitasako et al33 reported significant differences in bond strengths of resin cements adhered to dentin when the shear and tensile testing methods were compared. The differences in the results of these micro-bond tests are thought to have arisen from differing force directions and the resulting stress distribution pattern at the interface.34,35 The advantages of both methods require investigation if the most reliable universal testing method is to be determined. Our hypothesis was the bonding ability of PB to primary dentin is not different from that parental material (SE Bond) and the results of this study showed that μTBS and μSBS of PB are about 17% and 23% lower compared to SE Bond to primary teeth dentin, respectively. Thus, the hypothesis was rejected. The basic concept behind self-etching primers is that demineralization of the tooth structure and diffusion of the bonding agent around dentinal collagen fibers occur simultaneously and to the same depth.18 MDPB has a potential to be incorporated into dental resin-based materials such as dentin bonding primer/resin to provide bactericidal activity without causing adverse effect on biocompatibility.37 On the other hand, variations in bond strength can reflect a number of factors, such as specimen storage medium, bond strength test used and the different content of the materials. Further clinical trials are therefore required to confirm the data obtained from this laboratory study and to establish the value of antibacterial self etching bonding system under clinical situations of pediatric dentistry.

CONCLUSIONS

It was showed that antibacterial self-etching system Clearfil Protect Bond showed lower bond strength values compared to primary dentin than that of to Clearfil SE Bond on primary dentin.
  33 in total

1.  Efficacy of different adhesive techniques on bonding to root canal walls: an SEM investigation.

Authors:  M Ferrari; A Vichi; S Grandini
Journal:  Dent Mater       Date:  2001-09       Impact factor: 5.304

2.  Bactericidal effect of dentin primer containing antibacterial monomer methacryloyloxydodecylpyridinium bromide (MDPB) against bacteria in human carious dentin.

Authors:  S Imazato; Y Torii; T Takatsuka; K Inoue; N Ebi; S Ebisu
Journal:  J Oral Rehabil       Date:  2001-04       Impact factor: 3.837

Review 3.  Antibacterial properties of resin composites and dentin bonding systems.

Authors:  Satoshi Imazato
Journal:  Dent Mater       Date:  2003-09       Impact factor: 5.304

4.  Microtensile bond strengths of one- and two-step self-etch adhesives to bur-cut enamel and dentin.

Authors:  Jan De Munck; Bart Van Meerbeek; Inoue Satoshi; Marcos Vargas; Yasuhiro Yoshida; Steven Armstrong; Paul Lambrechts; Guido Vanherle
Journal:  Am J Dent       Date:  2003-12       Impact factor: 1.522

5.  Microstructure of primary tooth dentin.

Authors:  D A Sumikawa; G W Marshall; L Gee; S J Marshall
Journal:  Pediatr Dent       Date:  1999 Nov-Dec       Impact factor: 1.874

6.  Influence of selected variables on adhesion testing.

Authors:  C S Fowler; M L Swartz; B K Moore; B F Rhodes
Journal:  Dent Mater       Date:  1992-07       Impact factor: 5.304

7.  Antibacterial activity of dentine primer containing MDPB after curing.

Authors:  S Imazato; A Ehara; M Torii; S Ebisu
Journal:  J Dent       Date:  1998-03       Impact factor: 4.379

8.  Bacterial leakage around dental restorations: its effect on the dental pulp.

Authors:  G Bergenholtz; C F Cox; W J Loesche; S A Syed
Journal:  J Oral Pathol       Date:  1982-12

9.  Microtensile bond strength of a total-etching versus self-etching adhesive to caries-affected and intact dentin in primary teeth.

Authors:  Siriruk Nakornchai; Choltacha Harnirattisai; Rudee Surarit; Sukhum Thiradilok
Journal:  J Am Dent Assoc       Date:  2005-04       Impact factor: 3.634

10.  Antibacterial and conventional self-etching primer system: morphological evaluation of intact primary enamel.

Authors:  Márcia Daronch; Mario Fernando De Goes; Rosa Helena M Grande; Daniel C N Chan
Journal:  J Clin Pediatr Dent       Date:  2003       Impact factor: 1.065

View more
  3 in total

1.  The effect of repeated bonding on the shear bond strength of different resin cements to enamel and dentin.

Authors:  Ali Can Bulut; Saadet Sağlam Atsü
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

2.  Effect of chlorhexidine on bonding durability of two self-etching adhesives with and without antibacterial agent to dentin.

Authors:  Fereshteh Shafiei; Armaghan Alikhani; Ali Asghar Alavi
Journal:  Dent Res J (Isfahan)       Date:  2013-11

3.  The effect of cavity disinfectants on the micro-shear bond strength of dentin adhesives.

Authors:  Dina Wafik Elkassas; Elham Mostafa Fawzi; Ahmed El Zohairy
Journal:  Eur J Dent       Date:  2014-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.