Literature DB >> 19212270

Mitral annular shape, size, and motion in normals and in patients with cardiomyopathy: evaluation with computed tomography.

Hatem Alkadhi1, Lotus Desbiolles, Paul Stolzmann, Sebastian Leschka, Hans Scheffel, André Plass, Thomas Schertler, Pedro Trigo Trindade, Michele Genoni, Philippe Cattin, Borut Marincek, Thomas Frauenfelder.   

Abstract

OBJECTIVE: To assess prospectively, in healthy subjects and in patients with dilated cardiomyopathy (DCM) and hypertrophic obstructive cardiomyopathy (HOCM), the 3-dimensional (3D) shape, size, and motion of the mitral annulus (MA) using computed tomography (CT).
MATERIALS AND METHODS: Twenty patients with no cardiac abnormalities (referred to as normals), 15 with DCM, and 15 with HOCM as determined by echocardiography underwent contrast-enhanced, retrospectively electrocardiography (ECG)-gated 64-slice CT of the heart. The MA was manually segmented in 10% steps of the RR interval with dedicated 3D software employing the point-wrap algorithm. The MA shape, area size, change of the MA area, and apicobasal MA motion throughout the cardiac cycle was determined and compared between the groups. Intercommissural distances were measured with CT and compared with findings during surgery in 9 patients undergoing ring annuloplasty.
RESULTS: The MA was nonplanar in all phases and subjects, being largest in diastole and smallest in systole. The MA area was significantly (P < 0.001) larger in patients with DCM (11.5 +/- 4.1 cm/m) as compared with normals (5.5 +/- 0.9 cm/m) and HOCM (4.7 +/- 0.9 cm/m). The change of MA area throughout the cardiac cycle was significantly (P < 0.017) smaller in patients with DCM (12.2 +/- 3.3%/m) as compared with normals (20.0 +/- 7.9%/m) and HOCM (20.5 +/- 7.7%/m). The mean apicobasal motion was significantly (P < 0.017) smaller in patients with DCM (2.2 +/- 1.0 mm/m) as compared with normals (3.6 +/- 0.8 mm/m) and HOCM (2.7 +/- 0.7 mm/m). Intercommissural distances as determined by CT showed a good correlation (r = 0.68, P < 0.05) with intraoperative measurements (mean difference, 0.44 mm; limits of agreement, -2.73-3.62 mm).
CONCLUSION: Our study provides in vivo human data on the 3D shape, size, and motion of the MA in healthy subjects. Significant changes in size and motion of the MA were noted in patients with HOCM.

Entities:  

Mesh:

Year:  2009        PMID: 19212270     DOI: 10.1097/RLI.0b013e3181994a73

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  12 in total

1.  Dual-step prospective ECG-triggered 128-slice dual-source CT for evaluation of coronary arteries and cardiac function without heart rate control: a technical note.

Authors:  Gudrun Feuchtner; Robert Goetti; Andrè Plass; Stephan Baumueller; Paul Stolzmann; Hans Scheffel; Monika Wieser; Borut Marincek; Hatem Alkadhi; Sebastian Leschka
Journal:  Eur Radiol       Date:  2010-04-21       Impact factor: 5.315

Review 2.  Basic mechanisms of mitral regurgitation.

Authors:  Jacob P Dal-Bianco; Jonathan Beaudoin; Mark D Handschumacher; Robert A Levine
Journal:  Can J Cardiol       Date:  2014-07-02       Impact factor: 5.223

3.  Pathoanatomy of Mitral Regurgitation.

Authors:  Ilya Karagodin; Amita Singh; Roberto M Lang
Journal:  Struct Heart       Date:  2020-06-12

4.  Mitral annulus segmentation from four-dimensional ultrasound using a valve state predictor and constrained optical flow.

Authors:  Robert J Schneider; Douglas P Perrin; Nikolay V Vasilyev; Gerald R Marx; Pedro J del Nido; Robert D Howe
Journal:  Med Image Anal       Date:  2011-12-04       Impact factor: 8.545

Review 5.  Role of MDCT Imaging in Planning Mitral Valve Intervention.

Authors:  Rominder Grover; Mickael Ohana; Chesnal Dey Arepalli; Stephanie L Sellers; John Mooney; Shaw-Hua Kueh; Ung Kim; Philipp Blanke; Jonathon A Leipsic
Journal:  Curr Cardiol Rep       Date:  2018-03-06       Impact factor: 2.931

6.  Computed tomography for planning and postoperative imaging of transvenous mitral annuloplasty: first experience in an animal model.

Authors:  Simon H Sündermann; Sonja Gordic; Robert Manka; Nikola Cesarovic; Volkmar Falk; Francesco Maisano; Hatem Alkadhi
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-15       Impact factor: 2.357

Review 7.  Anatomy of the mitral valve apparatus: role of 2D and 3D echocardiography.

Authors:  Jacob P Dal-Bianco; Robert A Levine
Journal:  Cardiol Clin       Date:  2013-04-15       Impact factor: 2.213

8.  A simplified D-shaped model of the mitral annulus to facilitate CT-based sizing before transcatheter mitral valve implantation.

Authors:  Philipp Blanke; Danny Dvir; Anson Cheung; Jian Ye; Robert A Levine; Bruce Precious; Adam Berger; Dion Stub; Cameron Hague; Darra Murphy; Christopher Thompson; Brad Munt; Robert Moss; Robert Boone; David Wood; Gregor Pache; John Webb; Jonathon Leipsic
Journal:  J Cardiovasc Comput Tomogr       Date:  2014-10-07

9.  Sizing the mitral annulus in healthy subjects and patients with mitral regurgitation: 2D versus 3D measurements from cardiac CT.

Authors:  Sonja Gordic; Thi Dan Linh Nguyen-Kim; Robert Manka; Simon Sündermann; Thomas Frauenfelder; Francesco Maisano; Volkmar Falk; Hatem Alkadhi
Journal:  Int J Cardiovasc Imaging       Date:  2013-12-04       Impact factor: 2.357

10.  Dynamic changes of mitral valve annulus geometry at preprocedural CT: relationship with functional classes of regurgitation.

Authors:  Anna Palmisano; Valeria Nicoletti; Caterina Colantoni; Caterina Beatrice Monti; Luigi Pannone; Davide Vignale; Fatemeh Darvizeh; Eustachio Agricola; Simone Schaffino; Francesco De Cobelli; Antonio Esposito
Journal:  Eur Radiol Exp       Date:  2021-08-13
View more