PURPOSE: The purpose of this study was to compare the artificial tooth positional changes following the flasking and polymerization of complete dentures by a combination of two flasking methods and two polymerization techniques using computer graphic measurements.
MATERIALS AND METHODS: Four groups of waxed complete dentures (n = 10) were invested and polymerized using the following techniques: (1) adding a second investment layer of gypsum and conventional water bath polymerization (Control), (2) adding a second investment layer of gypsum and polymerization with microwave energy (Gypmicro), (3) adding a second investment layer of silicone (Zetalabor) and conventional polymerization (Silwater), and (4) adding a second investment layer of silicone and polymerization with microwave energy (Silmicro). For each specimen, six segments of interdental distances (A to F) were measured to determine the artificial tooth positions in the waxed and polymerized stages using software program AutoCad R14. The mean values of the changes were statistically compared by univariate ANOVA with Tukey post-hoc test at 5% significance.
RESULTS: There were no significant differences among the four groups, except for segment D of the Silmicro group (-0.004 +/- 0.032 cm) in relation to the Gypwater group (0.044 +/- 0.031 cm) (p < 0.05), which presented, respectively, expansion and shrinkage after polymerization.
CONCLUSIONS: Within the limitations of this study, it was concluded that although the differences were not statistically significant, the use of a silicone investment layer when flasking complete dentures resulted in the least positional changes of the artificial teeth regardless of the polymerization technique.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19210609     DOI: 10.1111/j.1532-849X.2008.00421.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  6 in total

1.  Teeth movement in denture and implant-supported prosthesis influenced by microwave flask systems.

Authors:  Rafael L X Consani; Leonardo G Sonehara; Marcelo F Mesquita; Valentim A R Barão; Conrado R Caetano
Journal:  J Oral Biol Craniofac Res       Date:  2015-07-15

2.  Influence of opacifiers on dimensional stability and detail reproduction of maxillofacial silicone elastomer.

Authors:  Marcelo C Goiato; Marcela F Haddad; Mário A C Sinhoreti; Daniela M dos Santos; Aldiéris A Pesqueira; Amália Moreno
Journal:  Biomed Eng Online       Date:  2010-12-16       Impact factor: 2.819

3.  The Influence of Thermal Curing Cycles on the Color Stability of Unfilled Polymethyl Methacrylate Teeth.

Authors:  Ram Basany; Vinod Bandela; Kulashekar Reddy Nandalur; Dileep Nag Vinnekota; Kiran Kumar Metta; Hari Kumar Mempally; Saraswathi Kanaparthi
Journal:  Cureus       Date:  2022-03-17

4.  Effect of three investing materials on tooth movement during flasking procedure for complete denture construction.

Authors:  Alaa'a M Salloum
Journal:  Saudi Dent J       Date:  2015-12-02

5.  Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study.

Authors:  Sumanth Babu; Shaurya Manjunath; Mayuri Vajawat
Journal:  Contemp Clin Dent       Date:  2016 Jan-Mar

6.  TiO2-Nanofillers Effects on Some Properties of Highly- Impact Resin Using Different Processing Techniques.

Authors:  Hawraa Khalid Aziz
Journal:  Open Dent J       Date:  2018-03-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.