Literature DB >> 19209343

Fabrication of a multichannel PDMS/glass analytical microsystem with integrated electrodes for amperometric detection.

Ney Henrique Moreira1, André Luis de Jesus de Almeida, Maria Helena de Oliveira Piazzeta, Dosil Pereira de Jesus, Ariane Deblire, Angelo Luiz Gobbi, José Alberto Fracassi da Silva.   

Abstract

The fabrication process of novel multichannel microfluidic devices with integrated electrodes for amperometric detection is described. Soft-lithography, lift-off and O(2) plasma surface activation sealing techniques were employed for rapid prototyping of cost effective PDMS/glass microchips. The capabilities of the proposed microdevices were demonstrated by the electrooxidation of hydroquinone and N-acetyl-p-aminophenol (APAP) on a Au working electrode at +800 mV and +700 mV, respectively, against a Au pseudo reference electrode, and of thiocyanate on a Cu working electrode at +700 mV against a Ag/AgCl (KCl saturated) reference electrode. Linear response over the range up to 1.0 mmol L(-1) for APAP and up to 4.0 mmol L(-1) for hydroquinone and thiocyanate were verified through calibration curves with correlation coefficients greater than 0.97 (minimum of five data points). The sensitivities for hydroquinone, thiocyanate, and APAP were 28, 19, and 78 microA mol(-1) L, respectively. Under the experimental conditions used, the estimated limits of detection were 0.21, 0.95, and 0.12 mmol L(-1) for hydroquinone, thiocyanate and APAP, respectively. The geometries of the devices were designed to allow fast calibration procedures and reliable results for in-field applications. Exerting a strong influence over the device performance, the sealing process was greatly enhanced by depositing auxiliary TiSiO(2) thin-films. The general performance of the system was verified by amperometric assays of N-acetyl-p-aminophenol standard solutions, and the influences exerted by the present fabrication methods regarding reproducibility and reliability are addressed. The proposed device was successfully applied in the determination of the concentration of APAP in two commercial formulations.

Entities:  

Year:  2008        PMID: 19209343     DOI: 10.1039/b807409g

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  4 in total

1.  A reproducible method for μm precision alignment of PDMS microchannels with on-chip electrodes using a mask aligner.

Authors:  J Cottet; C Vaillier; F Buret; M Frénéa-Robin; P Renaud
Journal:  Biomicrofluidics       Date:  2017-12-20       Impact factor: 2.800

2.  Integrated Multi-process Microfluidic Systems for Automating Analysis.

Authors:  Weichun Yang; Adam T Woolley
Journal:  JALA Charlottesv Va       Date:  2010-06-01

3.  Polydimethylsiloxane-based conducting composites and their applications in microfluidic chip fabrication.

Authors:  Xiuqing Gong; Weijia Wen
Journal:  Biomicrofluidics       Date:  2009-03-23       Impact factor: 2.800

4.  Multi-channel PMMA microfluidic biosensor with integrated IDUAs for electrochemical detection.

Authors:  Nongnoot Wongkaew; Peng He; Vanessa Kurth; Werasak Surareungchai; Antje J Baeumner
Journal:  Anal Bioanal Chem       Date:  2013-05-17       Impact factor: 4.142

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.