Literature DB >> 19207165

Application of bead array technology to simultaneous detection of human leucocyte antigen and human platelet antigen antibodies.

K Fujiwara1, K Shimano, H Tanaka, M Sekine, K Kashiwase, M Uchikawa, M Satake, K Nakajima.   

Abstract

BACKGROUND: Detection of antibodies against human leucocyte antigens (HLA) and human platelet antigens (HPA) is crucial for patients refractory to platelet transfusion therapy. However, a reliable and high-throughput method for HLA cross-matching and detecting HPA antibodies has not yet been described. STUDY DESIGN AND METHODS: Immunocomplex capture fluorescence analysis (ICFA) was developed for high-throughput, simultaneous detection of HLA and HPA antibodies. Microarray beads were separately coupled with monoclonal antibodies specific for CD36, CD41, CD42b, CD49b, CD61 and HLA class I antigens. Platelets reacting with patient serum were lysed and the lysates were incubated with the bead mixture to specifically capture antigen-antibody complexes via the epitopes on platelet glycoproteins or HLA antigens. The beads capturing immunocomplexes were then subjected to flow cytometric analysis.
RESULTS: Immunocomplex capture fluorescence analysis was validated using 50 serum samples containing HLA antibodies and 20 serum samples containing HPA antibodies. The method enabled the detection of all the HLA antibodies with a sensitivity comparable to that of the purified HLA antigen-coated pooled-bead assay (FlowPRA, One Lambda, Canoga Park, CA, USA). The method also enabled the detection of all the HPA antibodies with a sensitivity higher than that of the mixed passive haemagglutination.
CONCLUSION: In this study, we developed a rapid, simple and reliable method for the simultaneous analysis of HLA and HPA antibodies. ICFA can also be used as an alternative to the lymphocyte cytotoxicity test for HLA cross-matching.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19207165     DOI: 10.1111/j.1423-0410.2008.01140.x

Source DB:  PubMed          Journal:  Vox Sang        ISSN: 0042-9007            Impact factor:   2.144


  3 in total

Review 1.  Advances in alloimmune thrombocytopenia: perspectives on current concepts of human platelet antigens, antibody detection strategies, and genotyping.

Authors:  Tomoya Hayashi; Fumiya Hirayama
Journal:  Blood Transfus       Date:  2015-04-30       Impact factor: 3.443

2.  Novel method for simultaneously detecting HPA and HLA antibodies using Luminex microbeads.

Authors:  Sudan Tao; Shu Chen; Xiaozhen Hong; Ji He; Faming Zhu
Journal:  J Transl Med       Date:  2019-08-05       Impact factor: 5.531

3.  Platelet antibodies identification: comparison between two laboratory tests.

Authors:  Valeria de Freitas Dutra; Thiago Henrique Costa; Leandro Dinalli Santos; Marilia Fernandes Mascarenhas Sirianni; Maria Giselda Aravechia; José Mauro Kutner; Carolina Bonet Bub
Journal:  Hematol Transfus Cell Ther       Date:  2021-03-06
  3 in total