Literature DB >> 19203615

Lead(II) ion-selective electrode based on polyaminoanthraquinone particles with intrinsic conductivity.

Xin-Gui Li1, Xiao-Li Ma, Mei-Rong Huang.   

Abstract

A new polyvinylchloride membrane electrode was facilely prepared by using polyaminoanthraquinone (PAAQ) microparticles with an intrinsically electrical conductivity as a lead(II) ionophore. It is found that the electrode performance will significantly be improved with adding 1 wt% PAAQ microparticles and decreasing the membrane thickness. A 90 microm-thick membrane electrode consisting of PAAQ(salt):polyvinyl chloride:dioctylphthalate:sodium tetraphenylborate of 1:33:66:1 (wt) but without any traditional lead(II) ionophore achieved the optimal performance and exhibited a good Nernstian response for Pb(II) ions over a wide concentration range from 2.5 x 10(-6) to 0.1M with a slope of 28.9 mV/decade and a detection limit down to 776 nM. A reasonably short response time of 12s was revealed together with a long lifetime over a period of around 4 months in a wide pH range between 2.8 and 5.2. A fixed interference method indicated that the electrode has an excellent selectivity for lead(II) ion over alkali, alkaline earth and other heavy metal ions. The proposed electrode has been also found to be a powerful indicator electrode for potentiometric titration of Pb(II) ions with EDTA. The electrode can be used to accurately monitor the Pb(II) pollution in environmental waters.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19203615     DOI: 10.1016/j.talanta.2008.11.045

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2010-06-15       Impact factor: 6.986

Review 2.  Recent trends in monitoring of European water framework directive priority substances using micro-sensors: a 2007-2009 review.

Authors:  Philippe Namour; Mathieu Lepot; Nicole Jaffrezic-Renault
Journal:  Sensors (Basel)       Date:  2010-08-26       Impact factor: 3.576

3.  A highly sensitive, selective and renewable carbon paste electrode based on a unique acyclic diamide ionophore for the potentiometric determination of lead ions in polluted water samples.

Authors:  M A Zayed; Walaa H Mahmoud; Ashraf A Abbas; Aya E Ali; Gehad G Mohamed
Journal:  RSC Adv       Date:  2020-05-06       Impact factor: 3.361

4.  Selective removal of lead ions from aqueous solutions using 1,8-dihydroxyanthraquinone (DHAQ) functionalized graphene oxide; isotherm, kinetic and thermodynamic studies.

Authors:  Mohammad Khazaei; Simin Nasseri; Mohammad Reza Ganjali; Mehdi Khoobi; Ramin Nabizadeh; Elham Gholibegloo; Shahrokh Nazmara
Journal:  RSC Adv       Date:  2018-02-02       Impact factor: 4.036

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.