Literature DB >> 19200485

On-line molecularly imprinted solid-phase extraction for the selective spectrophotometric determination of nicotine in the urine of smokers.

Eduardo Costa Figueiredo1, Daniela Mayra de Oliveira, Maria Elisa Pereira Bastos de Siqueira, Marco Aurélio Zezzi Arruda.   

Abstract

This work describes an on-line molecularly imprinted solid-phase extraction (MISPE) method for spectrophotometric determination of nicotine in urine samples of smokers. This method is based on manganese (VII) to manganese (VI) reduction in an alkaline medium, promoted by nicotine. Two wash solutions (1:4 (v/v) acetonitrile:sodium hydroxide--pH 11.4, and nitric acid--pH 2.5) were employed to circumvent interferences. Aqueous solutions containing nicotine plus different possible concomitants (cotinine, anabasine, norcotinine and caffeine) were tested individually. The analytical calibration curve was prepared in urine samples collected from non-smokers and spiked with nicotine standard from 1.1 to 60 micromol L(-1) (r(2)>0.998). The limit of quantification and the analytical frequency were 1.1 micromol L(-1) and 11 h(-1), respectively. The precision, evaluated using 3, 10 and 30 micromol L(-1) nicotine in urine, was 10, 10 and 4% (intra-day precision) and 12, 13 and 5% (inter-day precision), respectively. Accuracy was checked through high performance liquid chromatography and the results did not present significant differences at the 95% confidence level according to the Student's t-test.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19200485     DOI: 10.1016/j.aca.2008.12.045

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  5 in total

1.  Behavior of phenols and phenoxyacids on a bisphenol-A imprinted polymer. Application for selective solid-phase extraction from water and urine samples.

Authors:  Eliseo Herrero-Hernández; Rita Carabias-Martínez; Encarnacion Rodríguez-Gonzalo
Journal:  Int J Mol Sci       Date:  2011-05-20       Impact factor: 5.923

2.  Paper-Based Potentiometric Sensors for Nicotine Determination in Smokers' Sweat.

Authors:  Abd El-Galil E Amr; Ayman H Kamel; Abdulrahman A Almehizia; Ahmed Y A Sayed; Elsayed A Elsayed; Hisham S M Abd-Rabboh
Journal:  ACS Omega       Date:  2021-04-22

3.  Synthesis of graphene/DPA composite for determination of nicotine in tobacco products.

Authors:  Yanqiu Jing; Baohua Yu; Penghui Li; Bin Xiong; Yuyuan Cheng; Yaoguang Li; Chunguang Li; Xianyi Xiao; Mengqi Chen; Liangyuan Chen; Yu Zhang; Mingqin Zhao; Chuance Cheng
Journal:  Sci Rep       Date:  2017-10-30       Impact factor: 4.379

4.  A Novel Electrochemical Sensor for Detection of Nicotine in Tobacco Products Based on Graphene Oxide Nanosheets Conjugated with (1,2-Naphthoquinone-4-Sulphonic Acid) Modified Glassy Carbon Electrode.

Authors:  M Abd-Elsabour; Hesham M Alsoghier; Abdulrahman G Alhamzani; Mortaga M Abou-Krisha; Tarek A Yousef; Hytham F Assaf
Journal:  Nanomaterials (Basel)       Date:  2022-07-09       Impact factor: 5.719

5.  Comparison of the Conventional and Electroenhanced Direct-Immersion Solid-Phase Microextraction for Sampling of Nicotine in Biological Fluids of the Human Body.

Authors:  Sana Abdolhosseini; Ali Reza Ghiasvand; Nahid Heidari
Journal:  Molecules       Date:  2018-05-14       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.