Literature DB >> 19198895

Mid- to long-term outcome of instrumented anterior cervical fusion for subaxial injuries.

Heiko Koller1, Jeremy Reynolds, Juliane Zenner, Rosemarie Forstner, Axel Hempfing, Iris Maislinger, Klaus Kolb, Mark Tauber, Herbert Resch, Michael Mayer, Wolfgang Hitzl.   

Abstract

The management of patients with subaxial cervical injuries lacks consensus, particularly in regard to the decision which surgical approach or combination of approaches to use and which approach yields the best clinical outcome in the distinct injury. The trauma literature is replete with reports of surgical techniques, complications and gross outcome assessment in heterogeneous samples. However, data on functional and clinical outcome using validated outcome measures are scanty. Therefore, the authors performed a study on plated anterior cervical decompression and fusion for unstable subaxial injuries with focus on clinical outcome. For the purpose of a strongly homogenous subgroup of patients with subaxial injuries without spinal cord injuries, robust criteria were applied that were fulfilled by 28 patients out of an original series of 131 subaxial injuries. Twenty-six patients subjected to 1- and 2-level fusions without having spinal cord injury could be surveyed after a mean of 5.5 years (range 16-128 months). The cervical spine injury severity score averaged 9.6. Cross-sectional outcome assessment included validated outcome measures (Neck pain disability index, Cervical Spine Outcome Questionnaire, SF-36), the investigation of construct failure and successful surgical outcome were defined by strict criteria, the reconstruction and maintenance of local and total cervical lordosis, adjacent-segment degeneration and intervertebral motion, and the fusion-rate using an interobserver assessment. Self-rated clinical outcome was excellent or good in 81% of patients and moderate or poor in 19% that corresponded to the results of the validated outcome measures. Results of the NPDI averaged 12.4 +/- 12.7% (0-40). With the SF-36 mean physical and mental component summary scores were 47.0 +/- 9.8 (18.2-59.3) and 52.2 +/- 12.4 (14.6-75.3), respectively. Using merely non-constrained plates, construct failure was observed in 31% of cases and loss of local lordosis, expressed as a mean injury angle of 14 degrees, postoperative angle of -5.5 degrees and follow-up angle of -1 degree, was significant. However, total cervical lordosis was within the limits of normalcy (-24.3 degrees +/- 13.3) and fusion-rate was 88.5%. The progression of adjacent-level degeneration was shown to be significantly influenced by a decreased plate-to-disc-distance. Adjacent-level intervertebral motion was not altered due to the adjacent fusion, but reduced in the presence of advanced adjacent-level degeneration. Patients were more likely to maintain a high satisfaction level if they succeeded to maintain segmental lordosis (<0 degree), had a solid fusion, an increased plate-to-disc distance, and if they were judged to have a successful surgical outcome that included the absence of construct failure and reconstruction of lordosis within +/-1 SD of normalcy. Using validated outcome vehicles the interdependencies between radiographical, functional and clinical outcome parameters could be substantiated with statistically significant correlations. The use of validated outcome vehicles in a subgroup of patients with plated anterior cervical fusions for subaxial injuries is recommended. With future studies, it enables objective comparison of surgical techniques and related radiographical, functional and clinical outcome.

Entities:  

Mesh:

Year:  2009        PMID: 19198895      PMCID: PMC3233996          DOI: 10.1007/s00586-008-0879-3

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  88 in total

1.  The effect of locking fixation screws on the stability of anterior cervical plating.

Authors:  J M Spivak; D Chen; F J Kummer
Journal:  Spine (Phila Pa 1976)       Date:  1999-02-15       Impact factor: 3.468

Review 2.  Biomechanics of the cervical spine. I: Normal kinematics.

Authors:  N Bogduk; S Mercer
Journal:  Clin Biomech (Bristol, Avon)       Date:  2000-11       Impact factor: 2.063

3.  Noninvasive three-dimensional analysis of cervical spine motion in normal subjects in relation to age and sex. An experimental examination.

Authors:  W H Castro; A Sautmann; M Schilgen; M Sautmann
Journal:  Spine (Phila Pa 1976)       Date:  2000-02-15       Impact factor: 3.468

Review 4.  [Therapeutic concept for injuries of the lower cervical spine].

Authors:  M Hofmeister; V Bühren
Journal:  Orthopade       Date:  1999-05       Impact factor: 1.087

5.  Is the efficacy of the Cloward procedure overestimated? Technique of evaluation affects the outcome.

Authors:  D Javid; R Hedlund; L Vavruch; W Leszniewski
Journal:  Eur Spine J       Date:  2001-06       Impact factor: 3.134

6.  Cobb method or Harrison posterior tangent method: which to choose for lateral cervical radiographic analysis.

Authors:  D E Harrison; D D Harrison; R Cailliet; S J Troyanovich; T J Janik; B Holland
Journal:  Spine (Phila Pa 1976)       Date:  2000-08-15       Impact factor: 3.468

7.  Anterior fusion for rotationally unstable cervical spine fractures.

Authors:  R M Lifeso; M A Colucci
Journal:  Spine (Phila Pa 1976)       Date:  2000-08-15       Impact factor: 3.468

8.  A biomechanical comparison of modern anterior and posterior plate fixation of the cervical spine.

Authors:  Y Do Koh; T H Lim; J Won You; J Eck; H S An
Journal:  Spine (Phila Pa 1976)       Date:  2001-01-01       Impact factor: 3.468

9.  Anterior versus posterior plating in cervical corpectomy.

Authors:  H ElSaghir; H Böhm
Journal:  Arch Orthop Trauma Surg       Date:  2000       Impact factor: 3.067

10.  Sagittal plane segmental motion of the cervical spine. A new precision measurement protocol and normal motion data of healthy adults.

Authors:  W Frobin; G Leivseth; M Biggemann; P Brinckmann
Journal:  Clin Biomech (Bristol, Avon)       Date:  2002-01       Impact factor: 2.063

View more
  14 in total

1.  Anterior management of C2 fractures using miniplate fixation: outcome, function and quality of life in a case series of 15 patients.

Authors:  Axel Franke; Dan Bieler; Rebecca Wern; Tim Trotzke; Sebastian Hentsch; Erwin Kollig
Journal:  Eur Spine J       Date:  2018-03-23       Impact factor: 3.134

2.  Anterior surgical treatment of cervical spondylotic myelopathy: review article.

Authors:  John C Quinn; Paul D Kiely; Darren R Lebl; Alexander P Hughes
Journal:  HSS J       Date:  2014-08-08

3.  Posterior approach for cervical fracture-dislocations with traumatic disc herniation.

Authors:  Hiroaki Nakashima; Yasutsugu Yukawa; Keigo Ito; Masaaki Machino; Hany El Zahlawy; Fumihiko Kato
Journal:  Eur Spine J       Date:  2010-10-09       Impact factor: 3.134

4.  Cervical pedicle screw fixation in traumatic cervical subluxation after laminectomy using the pedicle axis view technique under fluoroscopy.

Authors:  Masaaki Machino; Yasutsugu Yukawa; Keigo Ito; Hiroaki Nakashima; Shunsuke Kanbara; Daigo Morita; Fumihiko Kato
Journal:  BMJ Case Rep       Date:  2012-10-10

5.  Study on accuracy and interobserver reliability of the assessment of odontoid fracture union using plain radiographs or CT scans.

Authors:  Heiko Koller; Klaus Kolb; Juliane Zenner; Jeremy Reynolds; Marcel Dvorak; Frank Acosta; Rosemarie Forstner; Michael Mayer; Mark Tauber; Alexander Auffarth; Anton Kathrein; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2009-11       Impact factor: 3.134

6.  In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device (ATPS part III).

Authors:  Heiko Koller; Wolfgang Hitzl; Frank Acosta; Mark Tauber; Juliane Zenner; Herbert Resch; Yasutsugu Yukawa; Oliver Meier; Rene Schmidt; Michael Mayer
Journal:  Eur Spine J       Date:  2009-07-03       Impact factor: 3.134

7.  C2-fractures: part II. A morphometrical analysis of computerized atlantoaxial motion, anatomical alignment and related clinical outcomes.

Authors:  Heiko Koller; Frank Acosta; Rosemarie Forstner; Juliane Zenner; Herbert Resch; Mark Tauber; Stefan Lederer; Alexander Auffarth; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2009-02-18       Impact factor: 3.134

8.  In vitro biomechanical evaluation of four fixation techniques for distractive-flexion injury stage 3 of the cervical spine.

Authors:  Thomas Henriques; Bryan W Cunningham; Paul C McAfee; Claes Olerud
Journal:  Ups J Med Sci       Date:  2015-03-06       Impact factor: 2.384

9.  Quality of Life in Adult Patients Receiving Cervical Fusion for Fresh Subaxial Cervical Injury: The Role of Associated Spinal Cord Injury.

Authors:  Panagiotis Korovessis; Evangelia Mpountogianni; Vasileios Syrimpeis; Maria Andriopoulou; Alkis Korovesis
Journal:  Biomed Res Int       Date:  2021-05-15       Impact factor: 3.411

Review 10.  Adjacent Segment Pathology after Anterior Cervical Fusion.

Authors:  Jae Yoon Chung; Jong-Beom Park; Hyoung-Yeon Seo; Sung Kyu Kim
Journal:  Asian Spine J       Date:  2016-06-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.