Literature DB >> 19198814

Measurement of longitudinal sulfur isotopic variations by laser ablation MC-ICP-MS in single human hair strands.

Rebeca Santamaria-Fernandez1, Justo Giner Martínez-Sierra, J M Marchante-Gayón, J Ignacio García-Alonso, Ruth Hearn.   

Abstract

A new method for the measurement of longitudinal variations of sulfur isotope amount ratios in single hair strands using a laser ablation system coupled to a multicollector inductively coupled plasma mass spectrometer (LA-MC-ICP-MS) is reported here for the first time. Ablation parameters have been optimized for the measurement of sulfur isotope ratios in scalp human hair strands of 80-120-microm thickness and different washing procedures have been evaluated. The repeatability of the method has been tested and the ability to measure sulfur isotopic variations in 1,000-microm-long hair segments has been evaluated. A horse hair sample previously characterized for carbon and nitrogen isotope ratios in an interlaboratory study has been characterized by LA-MC-ICP-MS to be used as an in-house standard for the bracketing of human hair strands. (34)S/(32)S isotope amount ratios have been measured and corrected for instrumental mass bias adopting the external standardization approach using National Institute of Standards and Technology (NIST) RM8553 and full uncertainty budgets have been calculated using the Kragten approach. Results are reported as both (34)S/(32)S isotope amount ratios and deltaS(V-CDT) values (sulfur isotopic differences relative to a reference sample expressed in the Vienna Canyon Diablo Troilite (V-CDT) scale) calculated using NIST RM8553, NIST RM8554, and NIST RM8556 to anchor results to the V-CDT scale. The main advantage of the new method versus conventional gas source isotope ratio mass spectrometry measurements is that longitudinal variations in sulfur isotope amount ratios can be resolved. Proof of concept is shown with human scalp hair strands from three individuals, two UK residents and one traveler (long periods of time abroad). The method enables monitoring of longitudinal isotope ratio variations in single hair strands. Absolute ratios are reported and delta(34)S(V-CDT) values are plotted for comparison. Slight variations of <1.2 per thousand were detected in the hair strands from UK residents whereas the traveler presented a variation of >5 per thousand. Thus, the measurement of sulfur isotopic variations in hair samples has potential to be an indicator of geographical origin and recent movements and could be used in combination with isotope ratio measurements in water/foodstuffs from different geographical locations to provide important information in nutritional and geographical studies.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19198814     DOI: 10.1007/s00216-009-2615-1

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

Review 1.  Stable Isotope Ratios as Biomarkers of Diet for Health Research.

Authors:  Diane M O'Brien
Journal:  Annu Rev Nutr       Date:  2015-05-27       Impact factor: 11.848

2.  Revealing details of stays abroad by sequential stable isotope analyses along human hair strands.

Authors:  Christine Lehn; Eva Maria Kalbhenn; Andreas Rossmann; Matthias Graw
Journal:  Int J Legal Med       Date:  2018-06-06       Impact factor: 2.686

3.  MC ICP-MS δ(34)S(VCDT) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane.

Authors:  Ondrej Hanousek; Torsten W Berger; Thomas Prohaska
Journal:  Anal Bioanal Chem       Date:  2015-10-05       Impact factor: 4.142

4.  Evaluation strategies and uncertainty calculation of isotope amount ratios measured by MC ICP-MS on the example of Sr.

Authors:  Monika Horsky; Johanna Irrgeher; Thomas Prohaska
Journal:  Anal Bioanal Chem       Date:  2016-01       Impact factor: 4.142

5.  Effect of toxic trace element detoxification, body fat reduction following four-week intake of the Wellnessup diet: a three-arm, randomized clinical trial.

Authors:  Su-Jin Jung; Woo-Lim Kim; Byung-Hyun Park; Seung-Ok Lee; Soo-Wan Chae
Journal:  Nutr Metab (Lond)       Date:  2020-06-22       Impact factor: 4.169

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.