Literature DB >> 1919742

The effect of flow on technetium-99m-teboroxime (SQ30217) and thallium-201 extraction and retention in rabbit heart.

R C Marshall1, E M Leidholdt, D Y Zhang, C A Barnett.   

Abstract

In order to evaluate the accuracy of blood flow measurement, the single-pass extraction, retention/wash-out and relative net uptake of 99mTc-teboroxime (SQ30217) and 201Tl were evaluated and compared in 20 isolated blood-perfused rabbit hearts at coronary flow rates ranging from 0.49 to 2.85 ml/g wet wt min-1. The average peak extraction of 201Tl (+/- s.d.) (0.67 +/- 0.11) marginally exceeded that of SQ30217 (0.62 +/- 0.12) (p = 0.06). Flow significantly affected the maximum net extraction of 201Tl and the 40-min net extractions of both 201Tl and SQ30217. Unexpectedly, the rate of 201Tl myocardial washout was significantly faster (p less than 0.05) than SQ30217 washout at all flow rates evaluated. Increasing coronary blood flow rate was associated with a more rapid clearance of both tracers from the myocardium (p less than 0.05 for both comparisons). The slope of the linear correlations between relative net SQ30217 uptake versus flow and relative net 201Tl uptake versus flow were found to be similar for up to 10 min after isotope injection. These data were interpreted to indicate that: 1. Thallium-201 might be slightly better extracted than SQ30217. 2. SQ30217 is cleared more slowly from the myocardium. 3. Thallium-201 and SQ30217 appear to be comparable tracers of myocardial perfusion for up to 10 min after injection under the single-pass conditions currently employed. 4. Additional studies are needed to clarify myocardial SQ30217 kinetics.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1919742

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  8 in total

1.  Novel 99mTc(III)-azide complexes [99mTc(N3)(CDO)(CDOH)2B-R] (CDOH2=cyclohexanedione dioxime) as potential radiotracers for heart imaging.

Authors:  Min Liu; Yumin Zheng; Ugur Avcibasi; Shuang Liu
Journal:  Nucl Med Biol       Date:  2016-05-09       Impact factor: 2.408

2.  Myocardial technetium 99m-labeled teboroxime clearance derived from canine scans differentiates severity of stenosis after dipyridamole.

Authors:  G Johnson; D K Glover; C B Hebert; R D Okada
Journal:  J Nucl Cardiol       Date:  1994 Jul-Aug       Impact factor: 5.952

3.  Transcapillary exchange of indium 111-labeled anticardiac myosin Fab and thallium 201 in isolated reperfused rabbit hearts.

Authors:  D J Meerdink; J A Leppo
Journal:  J Nucl Cardiol       Date:  1994 May-Jun       Impact factor: 5.952

4.  Interaction of technetium 99m-labeled teboroxime with red blood cells reduces the compound's extraction and increases apparent cardiac washout.

Authors:  S T Dahlberg; M P Gilmore; J A Leppo
Journal:  J Nucl Cardiol       Date:  1994 May-Jun       Impact factor: 5.952

Review 5.  Technetium-labeled myocardial imaging agents.

Authors:  A S Iskandrian; J Heo
Journal:  Int J Card Imaging       Date:  1992

6.  Effect of co-ligands on chemical and biological properties of (99m)Tc(III) complexes [(99m)Tc(L)(CDO)(CDOH)2BMe] (L=Cl, F, SCN and N3; CDOH2=cyclohexanedione dioxime).

Authors:  Yumin Zheng; Shundong Ji; Elena Tomaselli; Carley Ernest; Tom Freiji; Shuang Liu
Journal:  Nucl Med Biol       Date:  2014-08-01       Impact factor: 2.408

7.  Myocardial clearance of technetium-99m-teboroxime in reperfused injured canine myocardium.

Authors:  David R Okada; Gerald Johnson; Robert D Okada
Journal:  EJNMMI Res       Date:  2014-08-01       Impact factor: 3.138

8.  99mTc-3SPboroxime: A neutral 99mTc(III) radiotracer with high heart uptake and long myocardial retention.

Authors:  Xiao-Ying Xi; Lei Wang; Bailing Hsu; Zuo-Quan Zhao; Shuang Liu; Wei Fang
Journal:  J Nucl Cardiol       Date:  2020-03-16       Impact factor: 5.952

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.