Literature DB >> 19196175

Microdialysis of cytokines: methodological considerations, scanning electron microscopy, and determination of relative recovery.

Adel Helmy1, Keri L H Carpenter, Jeremy N Skepper, Peter J Kirkpatrick, John D Pickard, Peter J Hutchinson.   

Abstract

Cerebral microdialysis is a monitoring technique with expanding clinical and research utility following traumatic brain injury. This study's aim was to determine the relative recovery for 12 cytokines using both crystalloid (CNS perfusion fluid) and colloid (CNS perfusion fluid supplemented with 3.5% human serum albumin) perfusate. Six CMA71 microdialysis catheters (nominal molecular weight cut-off 100 kDa) were perfused in vitro with either crystalloid or colloid and the relative recovery (%) determined for the cytokines as follows (crystalloid/colloid perfusate): IL-1alpha (50.6/48), IL-1beta (34.6/38.4), IL-1ra (21.9/38.4), IL-2 (17.1/52.8), IL-4 (26/56.7), IL-6 (9.8/25.5), IL-8 (47.7/73.4), IL-10 (2.9/8.7), IL-17 (14.4/43.7), TNF-alpha (4.4/31.2), MIP-1alpha (31.8/55.6), and MIP-1beta (31.9/50.1). The colloid perfusate significantly improved relative recovery for nine of these cytokines ( p < 0.05), but not for IL-1alpha, IL-1beta, and IL-8. Relative recovery was related to apparent molecular weight of cytokine and to isoelectric point (pI), a surrogate marker of hydrophilicity. The mean fluid recovery for crystalloid and colloid perfusate was 92% and 145%, respectively. Scanning electron microscopy was utilized to investigate the ultrastructure of microdialysis membranes: (1) 20-kDa membrane, (2) 100-kDa membrane, and (3) ex vivo 100-kDa membrane. The 100-kDa membranes possessed multiple large cavities and the catheter examined after use in human brain clearly demonstrated cellular debris within the pores of the membrane. While colloid perfusate improves relative recovery, it causes a net influx of fluid into the microdialysis catheter, potentially dehydrating the extracellular space. This study is the first to systematically determine relative recovery in vitro for a wide range of cytokines. The two forms of perfusion fluid require direct comparison in vivo.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19196175     DOI: 10.1089/neu.2008.0719

Source DB:  PubMed          Journal:  J Neurotrauma        ISSN: 0897-7151            Impact factor:   5.269


  47 in total

1.  Are cutaneous microdialysis cytokine findings supported by end point biopsy immunohistochemistry findings?

Authors:  Florence Sjögren; Chris D Anderson
Journal:  AAPS J       Date:  2010-10-22       Impact factor: 4.009

Review 2.  How to Translate Time: The Temporal Aspects of Rodent and Human Pathobiological Processes in Traumatic Brain Injury.

Authors:  Denes V Agoston; Robert Vink; Adel Helmy; Mårten Risling; David Nelson; Mayumi Prins
Journal:  J Neurotrauma       Date:  2019-03-07       Impact factor: 5.269

3.  How minimally invasive is microdialysis sampling? A cautionary note for cytokine collection in human skin and other clinical studies.

Authors:  Julie A Stenken; Martin K Church; Carolyn A Gill; Geraldine F Clough
Journal:  AAPS J       Date:  2009-12-01       Impact factor: 4.009

4.  A pilot microdialysis study in brain tumor patients to assess changes in intracerebral cytokine levels after craniotomy and in response to treatment with a targeted anti-cancer agent.

Authors:  Jana Portnow; Behnam Badie; Xueli Liu; Paul Frankel; Shu Mi; Mike Chen; Timothy W Synold
Journal:  J Neurooncol       Date:  2014-03-15       Impact factor: 4.130

5.  In vitro and in vivo affinity microdialysis sampling of cytokines using heparin-immobilized microspheres.

Authors:  Jia Duo; Julie A Stenken
Journal:  Anal Bioanal Chem       Date:  2010-10-30       Impact factor: 4.142

6.  Antibody-enhanced microdialysis collection of CCL2 from rat brain.

Authors:  Anthony W Herbaugh; Julie A Stenken
Journal:  J Neurosci Methods       Date:  2011-05-11       Impact factor: 2.390

Review 7.  Animal modelling of traumatic brain injury in preclinical drug development: where do we go from here?

Authors:  Niklas Marklund; Lars Hillered
Journal:  Br J Pharmacol       Date:  2011-10       Impact factor: 8.739

8.  Localized delivery of dexamethasone-21-phosphate via microdialysis implants in rat induces M(GC) macrophage polarization and alters CCL2 concentrations.

Authors:  Geoffrey D Keeler; Jeannine M Durdik; Julie A Stenken
Journal:  Acta Biomater       Date:  2014-10-25       Impact factor: 8.947

9.  In vivo microdialysis sampling of cytokines from rat hippocampus: comparison of cannula implantation procedures.

Authors:  Thaddeus W Vasicek; Matthew R Jackson; Tina M Poseno; Julie A Stenken
Journal:  ACS Chem Neurosci       Date:  2013-04-02       Impact factor: 4.418

10.  Comparison of microdialysis sampling perfusion fluid components on the foreign body reaction in rat subcutaneous tissue.

Authors:  Geoffrey D Keeler; Jeannine M Durdik; Julie A Stenken
Journal:  Eur J Pharm Sci       Date:  2013-11-15       Impact factor: 4.384

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.