BACKGROUND AND
PURPOSE: Evolution of minimally invasive techniques has prompted interest in natural orifice transluminal endoscopic surgery (NOTES). Challenges for NOTES include loss of instrument rigidity, reduction in working envelopes, and collision of instrumentation. Magnetic anchoring and guidance system (MAGS) is one surgical innovation developed at our institution whereby instruments that are deployed intra-abdominally are maneuvered by the use of an external magnet. We present our initial animal experience with complete transvaginal NOTES nephrectomy using MAGS technology.
MATERIALS AND METHODS: Transvaginal NOTES nephrectomy was performed in two female pigs through a vaginotomy, using a 40-cm dual-lumen rigid access port inserted into the peritoneal cavity. A MAGS camera and cauterizer were deployed through the port and manipulated across the peritoneal surface by way of magnetic coupling via an external magnet. A prototype 70-cm articulating laparoscopic grasper introduced through the vaginal access port facilitated dissection after deployment of the MAGS instruments. The renal artery and vein were stapled en-bloc using an extra-long articulating endovascular stapler.
RESULTS: NOTES nephrectomies were successfully completed in both pigs without complications using MAGS instrumentation. The MAGS camera provided a conventional umbilical perspective of the kidney; the cauterizer, transvaginal grasper, and stapler preserved triangulation while avoiding instrument collisions. Operative duration for the two cases was 155 and 125 minutes, and blood loss was minimal.
CONCLUSIONS: NOTES nephrectomy using MAGS instrumentation is feasible. We believe this approach improves shortcomings of previously reported NOTES nephrectomies in that triangulation, instrument fidelity, and visualization are preserved while hilar ligation is performed using a conventional stapler without need for additional transabdominal trocars.

Entities:  

Mesh:

Year:  2009        PMID: 19196056     DOI: 10.1089/end.2008.0220

Source DB:  PubMed          Journal:  J Endourol        ISSN: 0892-7790            Impact factor:   2.942


  23 in total

1.  Transvaginal NOTES-assisted laparoscopic nephrectomy: a survival study in a sheep model.

Authors:  Francisco M Sánchez-Margallo; Francisco J Pérez; Miguel A Sánchez; Jaime Bachiller; Alvaro Juárez; Alvaro Serrano; María José Ribal; Antonio Alcaraz
Journal:  Surg Endosc       Date:  2011-10-20       Impact factor: 4.584

Review 2.  Use of magnetic anchoring and guidance systems to facilitate single trocar laparoscopy.

Authors:  Sara L Best; Jeffrey A Cadeddu
Journal:  Curr Urol Rep       Date:  2010-02       Impact factor: 3.092

3.  [Transvaginal access for NOTES].

Authors:  C Zornig; H Mofid; L Siemssen; C H Wenck
Journal:  Chirurg       Date:  2010-05       Impact factor: 0.955

4.  Dexterous miniature robot for advanced minimally invasive surgery.

Authors:  Amy C Lehman; Nathan A Wood; Shane Farritor; Matthew R Goede; Dmitry Oleynikov
Journal:  Surg Endosc       Date:  2010-06-12       Impact factor: 4.584

5.  Maximizing coupling strength of magnetically anchored surgical instruments: how thick can we go?

Authors:  Sara L Best; Richard Bergs; Makram Gedeon; Juan Paramo; Raul Fernandez; Jeffrey A Cadeddu; Daniel J Scott
Journal:  Surg Endosc       Date:  2010-06-09       Impact factor: 4.584

6.  NOTES: The question for minimal resection and sentinel node in early gastric cancer.

Authors:  Mitsuhiro Asakuma; Ronan A Cahill; Sang-Woong Lee; Eiji Nomura; Nobuhiko Tanigawa
Journal:  World J Gastrointest Surg       Date:  2010-06-27

7.  Magnetically anchored camera and percutaneous instruments maintain triangulation and improve cosmesis compared with single-site and conventional laparoscopic cholecystectomy.

Authors:  Nabeel A Arain; Luisangel Rondon; Deborah C Hogg; Jeffrey A Cadeddu; Richard Bergs; Raul Fernandez; Daniel J Scott
Journal:  Surg Endosc       Date:  2012-05-31       Impact factor: 4.584

8.  Magnetically anchored cautery dissector improves triangulation, depth perception, and workload during single-site laparoscopic cholecystectomy.

Authors:  Nabeel A Arain; Jeffrey A Cadeddu; Deborah C Hogg; Richard Bergs; Raul Fernandez; Daniel J Scott
Journal:  J Gastrointest Surg       Date:  2012-06-29       Impact factor: 3.452

9.  Usefulness in NOTES of an intra-abdominal antifogging wireless charge-coupled device (CCD) camera with pantograph-type needle unit for placement to the intra-abdominal wall.

Authors:  Takeshi Ohdaira; Kazuhiro Endo; Nozomi Abe; Yoshikazu Yasuda
Journal:  Surg Endosc       Date:  2009-06-18       Impact factor: 4.584

10.  Tissue compression analysis for magnetically anchored cautery dissector during single-site laparoscopic cholecystectomy.

Authors:  Lauren B Mashaud; Wareef Kabbani; Angel Caban; Sarah Best; Deborah C Hogg; Jeffrey A Cadeddu; Richard Bergs; Heather Beardsley; Raul Fernandez; Daniel J Scott
Journal:  J Gastrointest Surg       Date:  2011-04-12       Impact factor: 3.452

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.