Literature DB >> 19195836

Primary total hip arthroplasty with Duraloc cup in patients younger than 50 years: a 5- to 7-year follow-up study.

Tian Jialiang1, Mu Zhongyou, Pei Fuxing, Zhou Zongke, Shen Bin, Yang Jing.   

Abstract

We evaluated the clinical and radiographic results of 67 (64 patients) cementless Duraloc-300 cups for young active patients after a mean follow-up period of 6.2 years. The preoperative mean Harris hip score improved from 46.24 to 96.5 points at 5 years. The survivorship of the cup, using radiographically confirmed aseptic loosening as the end point, was 100% at 5 years. The mean rate of liner wear was 0.125 mm/y (00-0.39 mm/y). Acetabular osteolysis was found in 14% (9 hips) of the 67 hips, and the osteolysis is related to polyethylene wear (P = .0024) and sex (P = .001). Although there was no aseptic loosening of the components, there was a high rate of liner wear of the polyethylene liner and acetabular osteolysis.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19195836     DOI: 10.1016/j.arth.2008.12.002

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  The effect of poly sterilization on wear, osteolysis and survivorship of a press-fit cup at 10-year followup.

Authors:  Charles A Engh; Cara C Powers; Henry Ho; Sarah E Beykirch-Padgett; Robert H Hopper; C Anderson Engh
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Risk factors for revision of hip arthroplasties in patients younger than 30 years.

Authors:  Julien Girard; Christophe Glorion; François Bonnomet; Damien Fron; Henri Migaud
Journal:  Clin Orthop Relat Res       Date:  2010-11-18       Impact factor: 4.176

3.  Modular cementless cup for total hip arthroplasty: results at 4-year follow-up.

Authors:  Alessandro Bistolfi; Giuseppe Massazza; Federica Rosso; Stefano Ventura; Francesco Lagalla; Maurizio Crova
Journal:  Musculoskelet Surg       Date:  2012-01-06

Review 4.  A prospective osseointegration retrieval analysis of second generation cementless shells.

Authors:  M Curtin; E Pomeroy; M Grigoras; T Murphy; Fiachra E Rowan
Journal:  J Clin Orthop Trauma       Date:  2022-06-03

5.  Custom cementless stem improves hip function in young patients at 15-year followup.

Authors:  Xavier Flecher; Oliver Pearce; Sebastien Parratte; Jean-Manuel Aubaniac; Jean-Noel Argenson
Journal:  Clin Orthop Relat Res       Date:  2009-08-19       Impact factor: 4.176

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.