Literature DB >> 19195653

Use of a "hybrid" locking plate for complex metaphyseal fractures and nonunions about the humerus.

Allison B Spitzer1, Roy I Davidovitch, Kenneth A Egol.   

Abstract

PURPOSE: To review one surgeon's experience with a novel type of "hybrid" locking plate (which has both 3.5mm and 4.5mm locking holes) for difficult fractures of the meta-diaphyseal humeral shaft.
METHODS: Over a 2-year period, 24 patients who presented with a metaphyseal humeral fracture or nonunion (proximal or distal) were treated surgically by a single surgeon. A "hybrid" locking plate containing 3.5mm locking holes on one end and 4.5mm locking holes on the other end (Metaphyseal plate, Synthes, Paoli, Pa) was used in all patients. The selection of this implant was based on fracture location and bone quality. Fractures were operated on through an anterolateral or direct posterior approach. All fractures were secured with a minimum of three 4.5mm screws on one side of the fracture and three 3.5mm screws on the other side. All patients were treated with a similar post-operative protocol for early range of shoulder and elbow motion.
RESULTS: Three patients were lost to follow-up. The cohort consisted of 15 women and 6 men with a mean age of 49 years (range 18-78). There were 14 acute fractures and 7 nonunions. Twelve fractures involved the distal metaphyseal segment and 9 involved the proximal metaphyseal segment. Twenty-two patients completed a minimum 6-month clinical and radiographic follow-up and form the basis for this report. All 21 patients healed their fractures or nonunions at a mean of 4.5 months. There were no infections or hardware failures. In every case the "hybrid" nature of the plate design was felt to be advantageous.
CONCLUSION: This "second generation" metaphyseal locking plate, which affords the surgeon the ability to place a greater number of smaller calibre screws within a short bone segment, while using traditional large fragment screw fixation in the longer segment, is clearly an improvement in plate design. Meta-diaphyseal upper extremity long bones may serve as the most ideal location for this implant.

Entities:  

Mesh:

Year:  2009        PMID: 19195653     DOI: 10.1016/j.injury.2008.07.019

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  12 in total

1.  Older age does not affect healing time and functional outcomes after fracture nonunion surgery.

Authors:  David P Taormina; Brandon S Shulman; Raj Karia; Allison B Spitzer; Sanjit R Konda; Kenneth A Egol
Journal:  Geriatr Orthop Surg Rehabil       Date:  2014-09

2.  Dual plate fixation on distal third diaphyseal fracture of the humerus.

Authors:  Jun-Ku Lee; Yun-Sung Choi; Young-Suk Sim; Dae-Sung Choi; Soo-Hong Han
Journal:  Int Orthop       Date:  2016-12-01       Impact factor: 3.075

3.  Open reduction and fixation with a locking plate without bone grafting is a reasonable and safe option for treating proximal humerus nonunion.

Authors:  Stefan Quadlbauer; Georg J Hofmann; Martin Leixnering; Rudolf Rosenauer; Thomas Hausner; Jürgen Reichetseder
Journal:  Int Orthop       Date:  2018-02-13       Impact factor: 3.075

4.  Antero-lateral minimally invasive plate osteosynthesis (MIPO) with the radial nerve exploration for extra-articular distal-third diaphyseal fractures of the humerus.

Authors:  Wei Zhao; Wei Qu; Chongyang Fu; Huajun Jiang; Sida Liu; Chao Cheng
Journal:  Int Orthop       Date:  2017-06-02       Impact factor: 3.075

5.  Distal-third diaphyseal fractures of the humerus: choice of approach and surgical treatment.

Authors:  A Maresca; R Fantasia; M Cianforlini; N Giampaolini; S Cerbasi; R Pascarella
Journal:  Musculoskelet Surg       Date:  2016-08-12

6.  Subbrachial approach to humeral shaft fractures: new surgical technique and retrospective case series study.

Authors:  Vladimir Boschi; Zenon Pogorelic; Gordan Gulan; Katarina Vilovic; Hrvoje Stalekar; Kanito Bilan; Leo Grandic
Journal:  Can J Surg       Date:  2013-02       Impact factor: 2.089

7.  Single locking compression plate fixation of extra-articular distal humeral fractures.

Authors:  Malhar N Kumar; M R Ravishankar; Ravikiran Manur
Journal:  J Orthop Traumatol       Date:  2014-10-19

8.  Outcome of anatomic locking plate in extraarticular distal humeral shaft fractures.

Authors:  Deepak Jain; Gurpreet S Goyal; Rajnish Garg; Pankaj Mahindra; Mohammad Yamin; Harpal S Selhi
Journal:  Indian J Orthop       Date:  2017 Jan-Feb       Impact factor: 1.251

9.  Modified application of distal medial tibial locking plate as an alternative for fixation of an extraarticular distal-third diaphyseal humerus fracture.

Authors:  Babaji Thorat; Avtar Singh; Rajeev Vohra; Mohammad Arshad; Ravi Mavani
Journal:  Trauma Case Rep       Date:  2021-02-10

10.  Biomechanical Study of the Fixation Strength of Anteromedial Plating for Humeral Shaft Fractures.

Authors:  Yin-Feng Zheng; Jun-Lin Zhou; Xiao-Hong Wang; Lei Shan; Yang Liu
Journal:  Chin Med J (Engl)       Date:  2016-08-05       Impact factor: 2.628

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.