An experiment was undertaken to determine the intra- and interexaminer reliability of a paraspinal skin temperature differential instrument. Nineteen pain-free female chiropractic college students participated as subjects for the investigation. Three separate areas of the spine (C4-T2, T4-T8 and L2-L5) were examined for concordance between two examiners. Additionally, intraexaminer reliability was tested by having each examiner repeat the scanning procedure. Concordance for whether a temperature differential existed in a particular area was evaluated with the Kappa statistic. Kappas ranged from 0.034 to 0.6591 and were all statistically significant (p less than 0.05). This represented slight to moderate reliability in the area C4-T2 and substantial agreement in the region T4-T8. The lumbar region could not be evaluated with the Kappa statistic due to limited variation. Following agreement for a positive finding in a given area, the numerical ratings were evaluated for agreement with the intraclass correlation coefficient (ICC). The first observation between examiners indicated fair agreement (ICC = 0.2756, p = 0.0478). The second observation between examiners had substantial agreement (ICC = 0.6402, p = 0.042). Intraexaminer agreement was moderate for one examiner (ICC = 0.5078, p = 0.0016). The other examiner showed an excellent level of agreement (ICC = 0.8588, p less than 0.001) between observations.

Entities:  

Mesh:

Year:  1991        PMID: 1919373

Source DB:  PubMed          Journal:  J Manipulative Physiol Ther        ISSN: 0161-4754            Impact factor:   1.437


  5 in total

1.  Gonstead Chiropractic Technique (GCT).

Authors:  Robert Cooperstein
Journal:  J Chiropr Med       Date:  2003

2.  Reliability of infrared thermography in skin temperature evaluation of wheelchair users.

Authors:  I Rossignoli; P J Benito; A J Herrero
Journal:  Spinal Cord       Date:  2014-11-25       Impact factor: 2.772

3.  Intra-examiner and inter-examiner reproducibility of paraspinal thermography.

Authors:  Matthew McCoy; Ismay Campbell; Pamela Stone; Curtis Fedorchuk; Sameera Wijayawardana; Kirk Easley
Journal:  PLoS One       Date:  2011-02-11       Impact factor: 3.240

4.  The reliability of spinal motion palpation determination of the location of the stiffest spinal site is influenced by confidence ratings: a secondary analysis of three studies.

Authors:  Robert Cooperstein; Morgan Young
Journal:  Chiropr Man Therap       Date:  2016-12-20

5.  Review of methods used by chiropractors to determine the site for applying manipulation.

Authors:  John J Triano; Brian Budgell; Angela Bagnulo; Benjamin Roffey; Thomas Bergmann; Robert Cooperstein; Brian Gleberzon; Christopher Good; Jacquelyn Perron; Rodger Tepe
Journal:  Chiropr Man Therap       Date:  2013-10-21
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.