Literature DB >> 19192842

An in-vitro investigation of the effects of variable operating parameters on alumina air-abrasion cutting characteristics.

George Paolinelis1, Avijit Banerjee, Timothy F Watson.   

Abstract

Air-abrasion is a tooth preparation technology developed in the 1940s that is currently gaining popularity due to its compatibility with adhesive restorations. Variables, including propellant pressure, powder flow rate, nozzle angle and distance to the tooth surface abrasion time, can affect the cutting rate of the air-abrasion unit. A static setup and a more clinically realistic dynamic experimental setup have been used to assess the effect of these parameters of the cutting rate on an enamel analogue. By keeping each parameter fixed, its effect on the cutting rate was examined. The results showed that increasing the propellant pressure (20-100 PSI) caused an almost linear increase in the cutting rate in both setups. Increasing the powder flow rate (0.5 - 3 g/minute) concurrently increased the powder flow and caused an increase in the cutting rate but with a plateau differing for the different propellant pressures. The nozzle angles producing the highest cutting rates were 60 degrees and 75 degrees for static and dynamic cutting, respectively, with smaller and larger angles producing lower rates. Increasing abrasion time in static cutting and the nozzle advancement rate in dynamic cutting both caused an increase in the cutting rate. These findings are relevant for both clinicians, who might wish to alter the cutting rate of their instrument, and researchers, who should always control the numerous parameters in studies involving air-abrasion in order to control the variables, which can influence the end effect of air-abrasion.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19192842     DOI: 10.2341/08-52

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  3 in total

1.  An in vitro evaluation of selective demineralised enamel removal using bio-active glass air abrasion.

Authors:  Avijit Banerjee; Hiten Pabari; George Paolinelis; Ian D Thompson; Timothy F Watson
Journal:  Clin Oral Investig       Date:  2010-10-13       Impact factor: 3.573

2.  Development of a novel bioactive glass for air-abrasion to selectively remove orthodontic adhesives.

Authors:  Ayam A Taha; Robert G Hill; Padhraig S Fleming; Mangala P Patel
Journal:  Clin Oral Investig       Date:  2017-11-28       Impact factor: 3.573

3.  Physicochemical Properties of Dentine Subjected to Microabrasive Blasting and Its Influence on Bonding to Self-Adhesive Prosthetic Cement in Shear Bond Strength Test: An In Vitro Study.

Authors:  Marcin Szerszeń; Julia Higuchi; Barbara Romelczyk-Baishya; Bartłomiej Górski; Witold Łojkowski; Zbigniew Pakieła; Elżbieta Mierzwińska-Nastalska
Journal:  Materials (Basel)       Date:  2022-02-16       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.