Literature DB >> 19188068

Magnetic resonance imaging of in vivo patellofemoral kinematics after total knee arthroplasty.

R Dana Carpenter1, Jean Brilhault, Sharmila Majumdar, Michael D Ries.   

Abstract

Simulated partial weight bearing during magnetic resonance imaging of the knee was used to measure patellar tilt, medial-lateral patellar shift, and patellofemoral contact area in three groups of subjects; patients with posterior cruciate retaining (PCR) TKA, patients with bicruciate substituting (BCS) TKA, and healthy controls. Contact stress was also calculated based on the contact area and body weight-based estimates of contact force. Contact stress was significantly (p<0.05) higher in PCR knees (2.5+/-3.0 MPa) than in BCS knees (0.2+/-0.1 MPa) when knees were fully extended, but this difference was not significant (3.7+/-3.5 MPa for PCR knees vs. 1.4+/-1.9 MPa for BCS knees; p>0.05) in early flexion. The results also indicate that patellar tilt (normal=2.4 degrees +/-4.8 degrees, BCS=5.5 degrees +/-5.5 degrees, PCR=-3.0 degrees +/-6.9 degrees change in lateral tilt when moving from full extension to early flexion) and contact area (full extension: normal=267+/-111 mm(2), BCS=344+/-201 mm(2), PCR=83+/-80 mm(2); early flexion: normal=723+/-306 mm(2), BCS=417+/-290 mm(2), PCR=246+/-108 mm(2)) in BCS TKA mimic those in the normal knees more closely than PCR knees do. These results suggest that the patellar component in BCS TKA may be expected to experience less wear than the patellar component in PCR TKA over time.

Entities:  

Mesh:

Year:  2009        PMID: 19188068     DOI: 10.1016/j.knee.2008.12.016

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  9 in total

1.  Evaluation of patellofemoral joint in ADVANCE Medial-pivot total knee arthroplasty.

Authors:  Nobuaki Chinzei; Kazunari Ishida; Tomoyuki Matsumoto; Yuichi Kuroda; Atsushi Kitagawa; Ryosuke Kuroda; Toshihiro Akisue; Kotaro Nishida; Masahiro Kurosaka; Nobuhiro Tsumura
Journal:  Int Orthop       Date:  2013-08-08       Impact factor: 3.075

2.  Tibio-femoral and patello-femoral joint kinematics during navigated total knee arthroplasty with patellar resurfacing.

Authors:  C Belvedere; A Ensini; A Leardini; V Dedda; A Feliciangeli; F Cenni; A Timoncini; P Barbadoro; S Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-10       Impact factor: 4.342

3.  Statistical shape modeling predicts patellar bone geometry to enable stereo-radiographic kinematic tracking.

Authors:  Lowell M Smoger; Kevin B Shelburne; Adam J Cyr; Paul J Rullkoetter; Peter J Laz
Journal:  J Biomech       Date:  2017-05-17       Impact factor: 2.712

4.  MRI diagnosis of patellar clunk syndrome following total knee arthroplasty.

Authors:  Thomas J Heyse; Le Roy Chong; Jack Davis; Steven B Haas; Mark P Figgie; Hollis G Potter
Journal:  HSS J       Date:  2012-01-24

5.  In vivo comparison of medialized dome and anatomic patellofemoral geometries using subject-specific computational modeling.

Authors:  Azhar A Ali; Erin M Mannen; Paul J Rullkoetter; Kevin B Shelburne
Journal:  J Orthop Res       Date:  2018-03-06       Impact factor: 3.494

6.  Consecutive series of 226 journey bicruciate substituting total knee replacements: early complication and revision rates.

Authors:  Bernhard Christen; Michal Neukamp; Emin Aghayev
Journal:  BMC Musculoskelet Disord       Date:  2014-11-25       Impact factor: 2.362

7.  Short-term functional versus patient-reported outcome of the bicruciate stabilized total knee arthroplasty: prospective consecutive case series.

Authors:  Matthias Christen; Emin Aghayev; Bernhard Christen
Journal:  BMC Musculoskelet Disord       Date:  2014-12-16       Impact factor: 2.362

8.  Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement.

Authors:  G B Sharma; S K Saevarsson; S Amiri; S Montgomery; H Ramm; D D Lichti; R Lieck; S Zachow; C Anglin
Journal:  Bone Joint Res       Date:  2012-10-01       Impact factor: 5.853

9.  Second-generation bi-cruciate stabilized total knee system has a lower reoperation and revision rate than its predecessor.

Authors:  Bernhard Christen; Branko Kopjar
Journal:  Arch Orthop Trauma Surg       Date:  2018-08-25       Impact factor: 3.067

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.