| Literature DB >> 19188003 |
Dennis J Viscusi1, Mike Bergman2, Edward Sinkule1, Ronald E Shaffer3.
Abstract
BACKGROUND: Organizations are stockpiling respirators to prepare for an influenza pandemic. To understand better the effects of prolonged storage, this investigation evaluated the filtration efficiency of 21 different models of National Institute for Occupational Safety and Health (NIOSH)-certified disposable N95 filtering face piece respirators. These respirators had been stored in their original packaging for a period of at least 6 years in research laboratories and dry warehouse facilities, ranging in temperature between 15 degrees C and 32 degrees C and relative humidity between 20% and 80%.Entities:
Mesh:
Substances:
Year: 2009 PMID: 19188003 PMCID: PMC7132679 DOI: 10.1016/j.ajic.2008.09.021
Source DB: PubMed Journal: Am J Infect Control ISSN: 0196-6553 Impact factor: 2.918
Description of N95FFRs
| Manufacturer | Model | Size | Description | Dating on package | Estimated purchase date |
|---|---|---|---|---|---|
| Tecnol | PFR95-210 | Regular | Flat fold | No date | pre-May-2001 |
| Gerson | 2737 | One size fits all | Cup | No date | pre-June-1997 |
| Willson | 1410N95 | One size fits all | Cup | Jan-99 | January-1999 |
| Willson | N9501M | Medium | Cup | No date | pre-May-2001 |
| Willson | N9510M | Medium | Cup | No date | February-2000 |
| AOSafety | 50257 | Medium/large | Fold pleats | No date | February-1999 |
| 3M | 8210 | One size fits all | Cup | No date | March-1999 |
| Moldex | 2207N95 | Alternate shape | Cup | Exp. 12 2000 | January-1999 |
| 3M | 8212 | One size fits all | Cup | No date | December-1999 |
| Moldex | 2300N95 | Medium/large | Cup | No date | January-1999 |
| 3M | 8512 | One size fits all | Cup | No date | December-1999 |
| San Huei | SH3810 | One size fits all | Cup | Mfgr. 1997 01 2000 01 | pre-May-2001 |
| Willson | N9520FS | Small | Flat fold | No date | February-2000 |
| North | 7175N95 | One size fits all | Cup | No date | February-1999 |
| US Safety | ADN95 | One size fits all | Cup | No date | May-2002 |
| Survivair | 1930 | Large | Flat fold | No date | pre-June-1997 |
| Moldex | 2700N95 | Medium/large | Cup | Exp. 7 2002 | December-1999 |
| Magid | KR795 | One size fits all | Cup | No date | June-2001 |
| MSA | Affinity Pro | Medium | Cup | No date | pre-May-2001 |
| Sellstrom | Econ-Air-NC | One size fits all | Cup | Mfgr. 06 1999Exp. 06 2002 | June-2001 |
| Draeger | Piccola | One size fits all | Flat fold | Exp. 06 2004 | June-2001 |
Purchase date based on the NIOSH project when purchase records were not available.
TSI 8130 AFT means and standard deviations for resistance and penetration for 21 N95FFRs following prolonged storage∗
| Resistance at maximum penetration (mm H2O) | Initial penetration (%) | Maximum penetration (%) | |||||
|---|---|---|---|---|---|---|---|
| Manufacturer | Model | Mean | SD | Mean | SD | Mean | SD |
| Tecnol | PFR95-210 | 9.70 | 1.25 | 0.94 | 0.14 | 1.05 | 0.17 |
| Gerson | 2737 | 10.43 | 0.64 | 5.83 | 1.05 | 5.83 | 1.05 |
| Willson | 1410N95 | 30.07 | 3.76 | 2.91 | 0.72 | 2.94 | 0.75 |
| Willson | N9501M | 11.17 | 0.38 | 1.53 | 0.39 | 1.56 | 0.41 |
| Willson | N9510M | 11.20 | 1.28 | 0.95 | 0.27 | 0.95 | 0.27 |
| AOSafety | 50257 | 12.37 | 0.80 | 1.24 | 0.19 | 1.25 | 0.19 |
| 3M | 8210 | 12.23 | 0.06 | 0.65 | 0.05 | 2.15 | 0.19 |
| Moldex | 2207N95 | 8.67 | 0.15 | 3.85 | 0.72 | 3.88 | 0.72 |
| 3M | 8212 | 17.13 | 2.31 | 1.19 | 0.98 | 2.39 | 1.46 |
| Moldex | 2300N95 | 11.43 | 1.29 | 4.00 | 0.37 | 4.00 | 0.37 |
| 3M | 8512 | 22.03 | 2.83 | 0.39 | 0.11 | 0.98 | 0.46 |
| San Huei | SH3810 | 16.90 | 1.11 | 1.82 | 0.39 | 2.36 | 0.47 |
| Willson | N9520FS | 16.30 | 0.46 | 0.77 | 0.40 | 1.01 | 0.26 |
| North | 7175N95 | 12.63 | 0.15 | 3.94 | 0.09 | 3.94 | 0.09 |
| US Safety | ADN95 | 20.80 | 0.52 | 2.12 | 1.10 | 2.24 | 1.32 |
| Survivair | 1930 | 7.40 | 0.10 | 1.41 | 0.13 | 1.41 | 0.13 |
| Moldex | 2700N95 | 14.03 | 0.49 | 1.84 | 0.02 | 1.84 | 0.02 |
| Magid | KR795 | 12.13 | 0.23 | 5.44 | 1.95 | 5.59 | 1.97 |
| MSA | Affinity Pro | 11.10 | 0.53 | 1.26 | 0.30 | 1.26 | 0.30 |
| Sellstrom | Econ-Air-NC | 11.07 | 0.38 | 2.81 | 0.49 | 2.84 | 0.49 |
| Draeger | Piccola | 10.50 | 0.79 | 3.28 | 0.51 | 3.28 | 0.51 |
SD, standard deviation.
N95 respirators were loaded with NaCl aerosol until their maximum penetration was observed.
Values exceed the 5% NIOSH certification penetration criterion for N95FFR.