Literature DB >> 19187938

A new approach to the determination of column overload characteristics in reversed-phase liquid chromatography.

Jun Dai1, Peter W Carr, David V McCalley.   

Abstract

Column overloading is very common during the separations of basic analytes in analytical scale reversed-phase liquid chromatography (RPLC). Due to the complex interactions of ionic analytes with stationary and mobile phases, only a very small amount of ionized sample compared to the amount of nonpolar solute can be injected before the peak shape is distorted by non-linear chromatographic processes. Often the amount that can be injected before overload is observed is so small that the signal is quite noisy, thereby making the measured plate count imprecise and possibly inaccurate. The purpose of the present study was to develop a practical method for the precise measurement of the plate count and a column overload parameter using a simple but mathematically rigorous model of Langmuirian non-linear chromatography. An "overload profile", i.e. a plot of apparent plate count versus amount injected, is characterized by two parameters: the limiting plate count (N(0)) and the column sample loading capacity (omega(0.5)). The limiting plate count is the plate count that should be observed when the amount of sample injected is so small that a linear isotherm pertains. The column sample loading capacity, which is taken as the sample load that leads to a plate count equal to half of the limiting plate count, is a measure of the maximum amount of sample that can be injected into that column. The approach was tested by applying it to the study of cationic analytes in RPLC. We show that N(0) under constant conditions (column length, flow rate, mobile phase composition, etc.) is almost independent of column type (manufacturer); however, different column types (at the same length, diameter and flow rate) exhibit clear differences in their sample loading capacity (omega(0.5)). We believe that for most well packed type B columns, the column sample loading capacity and not the limiting plate count is the more important property that accounts for most of the apparent differences in peak width when different types of columns are examined.

Entities:  

Mesh:

Year:  2009        PMID: 19187938     DOI: 10.1016/j.chroma.2009.01.036

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Novel ultra stable silica-based stationary phases for reversed phase liquid chromatography--study of a hydrophobically assisted weak acid cation exchange phase.

Authors:  Yu Zhang; Peter W Carr
Journal:  J Chromatogr A       Date:  2010-11-16       Impact factor: 4.759

2.  Development of a carbon clad core-shell silica for high speed two-dimensional liquid chromatography.

Authors:  Changyub Paek; Yuan Huang; Marcelo R Filgueira; Alon V McCormick; Peter W Carr
Journal:  J Chromatogr A       Date:  2012-01-11       Impact factor: 4.759

3.  Effect of mobile phase anionic additives on selectivity, efficiency, and sample loading capacity of cationic drugs in reversed-phase liquid chromatography.

Authors:  Jun Dai; Peter W Carr
Journal:  J Chromatogr A       Date:  2009-08-03       Impact factor: 4.759

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.