Arrhythmias induced by device antitachycardia therapy due to diagnostic nonspecificity.

N J Johnson1, F E Marchlinski.   

Abstract

New technology has produced automatic cardioverter-defibrillators capable of delivering antitachycardia pacing, as well as low and high energy shocks and backup bradycardia pacing. These expanded treatment options have led to a wider range of clinical applications for such devices, including the treatment of ventricular tachycardias with longer cycle lengths, which may overlap the cycle lengths of some supraventricular arrhythmias. The diagnostic capability of these devices, although improved, has not advanced sufficiently to ensure reliable discrimination between all supraventricular and ventricular arrhythmias. Two cases are presented in which device-mediated pacing therapy, triggered by supraventricular arrhythmias, induced ventricular tachycardia requiring additional therapeutic intervention. This report illustrates the therapeutic versatility and some of the potential pitfalls, of the recently developed devices and reviews the status of automatic arrhythmia identification technology.

Entities:  

Mesh:

Year:  1991        PMID: 1918719     DOI: 10.1016/0735-1097(91)90566-r

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  5 in total

1.  Prospective evaluation of the quality and long-term stability of atrial signals in non-thoracotomy defibrillation electrodes: comparison of four different endocardial electrograms.

Authors:  C Wolpert; W Jung; S Spehl; B Schumacher; H Omran; B Esmailzadeh; B Lüderitz
Journal:  J Interv Card Electrophysiol       Date:  1998-12       Impact factor: 1.900

Review 2.  Interactions of antiarrhythmic drugs and implantable devices in controlling ventricular tachycardia and fibrillation.

Authors:  Yadavendra S Rajawat; Darryl Dias; Edward P Gerstenfeld; Sanjay Dixit; Bindi Shah; Andrea M Russo; Francis E Marchlinski
Journal:  Curr Cardiol Rep       Date:  2002-09       Impact factor: 2.931

3.  Dual chamber implantable cardioverter defibrillator benefits and limitations.

Authors:  K Fan; K Lee; C P Lau
Journal:  J Interv Card Electrophysiol       Date:  1999-10       Impact factor: 1.900

4.  [Stored electrograms to differenciate between adequate and inadequate ICD therapy].

Authors:  D Müller; E Hoffman; M Fiek; A Grünewald; G Steinbeck
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03

5.  Relevance of Monitoring Atrial Fibrillation in Clinical Practice.

Authors:  Thorsten Lewalter; Giuseppe Boriani
Journal:  Arrhythm Electrophysiol Rev       Date:  2012-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.