Literature DB >> 1918707

Transcatheter closure of a large patent ductus arteriosus with the clamshell septal umbrella.

N D Bridges1, S B Perry, I Parness, J F Keane, J E Lock.   

Abstract

In 14 patients undergoing transcatheter closure of a large (greater than 4 mm diameter) patent ductus arteriosus, occlusion was attempted with use of the Bard Clamshell septal umbrella. Patient age ranged from 0.7 to 30.4 years. Isolated patent ductus arteriosus was present in 11 patients; 3 had additional congenital heart lesions. Moderate or severe pulmonary hypertension was present in four patients. The diameter of the patent ductus arteriosus ranged from 4.5 to 14 mm, as determined by contrast injection through an 11F sheath or by balloon sizing; it appeared larger by this method than by the standard angiographic method. All 14 patent ductus arteriosi were successfully closed. Prior embolization of a Rashkind umbrella was the reason for using a Clamshell device in three patients; one additional embolization of a Clamshell device occurred. All errant devices were retrieved at cardiac catheterization, without associated hemodynamic instability. No other complications occurred. Among the 14 patients, 11 had complete ductal closure by Doppler color flow mapping at last follow-up and 3 had trivial residual flow. All four patients having associated complex lesions or pulmonary hypertension, or both, had symptomatic improvement after the procedure, although one child (with Shone's anomaly) died 3 months later. The Clamshell device provides stable and effective closure of a large patent ductus arteriosus, and allows transcatheter closure to be offered to some patients who were previously considered unsuitable for this procedure.

Entities:  

Mesh:

Year:  1991        PMID: 1918707     DOI: 10.1016/0735-1097(91)90551-j

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  4 in total

1.  Patent Ductus Arteriosus.

Authors: 
Journal:  Curr Treat Options Cardiovasc Med       Date:  1999-12

2.  Occlusion of the neonatal patent ductus arteriosus with a simple retrievable device: a feasibility study.

Authors:  M B Neuss; J Y Coe; F Tio; T P Le; R Grabitz; D A Redel
Journal:  Cardiovasc Intervent Radiol       Date:  1996 May-Jun       Impact factor: 2.740

3.  Transcatheter closure of large patent ductus arteriosus (> or = 4 mm) with multiple Gianturco coils: immediate and mid-term results.

Authors:  Z M Hijazi; R L Geggel
Journal:  Heart       Date:  1996-12       Impact factor: 5.994

Review 4.  Paediatric cardiac catheterization: innovations.

Authors:  J J Javorski; D D Hansen; P C Laussen; M L Fox; J Lavoie; F A Burrows
Journal:  Can J Anaesth       Date:  1995-04       Impact factor: 5.063

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.