Literature DB >> 19186112

3-Mercaptopropylphosphonic acid modified gold electrode for electrochemical detection of dopamine.

Yu Chen1, Li-Rong Guo, Wei Chen, Xiao-Jing Yang, Bo Jin, Li-Min Zheng, Xing-Hua Xia.   

Abstract

It is reported for the first time that the phosphonic acid terminated self-assembled layers assembled on a gold surface could be used as a functional interface to sensitively and selectively detect dopamine (DA) in the presence of highly concentrated ascorbic acid (AA). X-ray photoelectron spectroscopic (XPS) and reductive desorption measurements proved that the 3-mercaptopropylphosphonic acid [HS-(CH(2))(3)-PO(3)H(2), MPPA] was successfully immobilized on the gold surface via S-Au bond. Making use of the electrostatic interactions between the negatively charged phosphonic acid groups on the electrode surface and DA and AA, the MPPA modified electrode was successfully used to electrochemically discriminate between DA and AA. Cyclic voltammetry measurements shown that the MPPA modified electrodes almost completely inhibited the electrochemical reaction of AA. Therefore, DA can be selectively and sensitively determined by using the differential pulse voltammetry technique although high concentration of AA is present.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19186112     DOI: 10.1016/j.bioelechem.2008.12.005

Source DB:  PubMed          Journal:  Bioelectrochemistry        ISSN: 1567-5394            Impact factor:   5.373


  5 in total

1.  Simultaneous voltammetric detection of dopamine, ascorbic acid and uric acid using a poly(2-(N-morpholine)ethane sulfonic acid)/RGO modified electrode.

Authors:  Keying Zhang; Na Zhang; Li Zhang; Hongyan Wang; Hongwei Shi; Qiao Liu
Journal:  RSC Adv       Date:  2018-01-30       Impact factor: 4.036

2.  A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV).

Authors:  Yifan Dai; Alireza Molazemhosseini; Chung Chiun Liu
Journal:  Biosensors (Basel)       Date:  2017-02-19

3.  Smartphone-Based Electrochemical Potentiostat Detection System Using PEDOT: PSS/Chitosan/Graphene Modified Screen-Printed Electrodes for Dopamine Detection.

Authors:  Xiaoyan Shen; Feng Ju; Guicai Li; Lei Ma
Journal:  Sensors (Basel)       Date:  2020-05-14       Impact factor: 3.576

4.  Flexible sensor with electrophoretic polymerized graphene oxide/PEDOT:PSS composite for voltammetric determination of dopamine concentration.

Authors:  Seung Hyeon Ko; Seung Wook Kim; Yi Jae Lee
Journal:  Sci Rep       Date:  2021-10-26       Impact factor: 4.379

5.  Single-Use Disposable Electrochemical Label-Free Immunosensor for Detection of Glycated Hemoglobin (HbA1c) Using Differential Pulse Voltammetry (DPV).

Authors:  Alireza Molazemhosseini; Luca Magagnin; Pasquale Vena; Chung-Chiun Liu
Journal:  Sensors (Basel)       Date:  2016-07-01       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.