Volatile organic compounds and formaldehyde as explaining factors for sensory irritation in office environments.

H Salonen1, A-L Pasanen, S Lappalainen, H Riuttala, T Tuomi, P Pasanen, B Back, K Reijula.   

Abstract

This study's database comprised results of volatile organic compound (VOC) measurements from 176 office buildings. In 23 of the 176 buildings, formaldehyde measurements were also conducted. It was suspected that the buildings had indoor air problems, but a walk-through inspection did not reveal any clear, abnormal contaminant sources. The 50 most abundant VOCs and their concentrations in 520 air samples were analyzed. The irritation potency was estimated for 33 out of the 50 common VOCs and their mixtures, as well as for formaldehyde. This information was used to calculate the recommended indoor air levels (RILs) for the VOCs. The RILs were considerably higher than the measured mean indoor air concentrations in the buildings. However, the RIL for formaldehyde was exceeded in most of the 23 buildings studied. According to the evaluation of irritation potency, formaldehyde was a more likely cause of sensory irritation than the mixture of common nonreactive VOCs at the concentrations that occurred in the buildings without abnormal indoor sources. Furthermore, environmental symptoms of office workers were characterized in 20 office buildings (including the database of 176 office buildings) with the aid of an indoor air questionnaire. The most frequent symptoms related to the indoor environment were involved the upper respiratory tract. However, no relationship could be shown between the reported symptoms and the occurrence of VOC and formaldehyde concentrations in these buildings. Generally, the study results indicated that formaldehyde was the more likely agent causing sensory irritation than the mixture of the common nonreactive VOCs at the concentrations occurring in the buildings without abnormal indoor sources.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19184725     DOI: 10.1080/15459620902735892

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  13 in total

1.  Evaluating a persistent nuisance odor in an office building.

Authors:  Diana M Ceballos; Gregory A Burr
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

2.  Formaldehyde in the indoor environment.

Authors:  Tunga Salthammer; Sibel Mentese; Rainer Marutzky
Journal:  Chem Rev       Date:  2010-04-14       Impact factor: 60.622

3.  Public Participation in Air Sampling and Water Quality Test Kit Development to Enable Citizen Science.

Authors:  Erin N Haynes; Timothy J Hilbert; Rusty Roberts; John Quirolgico; Rachael Shepler; Gerry Beckner; Jennifer Veevers; Jeff Burkle; Roman Jandarov
Journal:  Prog Community Health Partnersh       Date:  2019

4.  Indoor formaldehyde removal by three species of Chlorphytum Comosum under the long-term dynamic fumigation system.

Authors:  Jian Li; Jiaochan Zhong; Ting Zhan; Qinghui Liu; Liushui Yan; Mingming Lu
Journal:  Environ Sci Pollut Res Int       Date:  2019-11-19       Impact factor: 4.223

5.  Formaldehyde exposure induces differentiation of regulatory T cells via the NFAT-mediated T cell receptor signalling pathway in Yucatan minipigs.

Authors:  Jeongsik Park; Goo-Hwa Kang; Youngkyu Kim; Ju Young Lee; Jeong Ah Song; Jeong Ho Hwang
Journal:  Sci Rep       Date:  2022-05-17       Impact factor: 4.996

6.  Exposure to volatile organic compounds in healthcare settings.

Authors:  Ryan F LeBouf; M Abbas Virji; Rena Saito; Paul K Henneberger; Nancy Simcox; Aleksandr B Stefaniak
Journal:  Occup Environ Med       Date:  2014-07-10       Impact factor: 4.402

7.  Air monitoring of volatile organic compounds at relevant receptors during hydraulic fracturing operations in Washington County, Pennsylvania.

Authors:  Joshua R Maskrey; Allison L Insley; Erin S Hynds; Julie M Panko
Journal:  Environ Monit Assess       Date:  2016-06-16       Impact factor: 2.513

8.  Measurements of chlorinated volatile organic compounds emitted from office printers and photocopiers.

Authors:  Joanna Kowalska; Małgorzata Szewczyńska; Małgorzata Pośniak
Journal:  Environ Sci Pollut Res Int       Date:  2014-10-18       Impact factor: 4.223

9.  Assessment of Chemical Risks in Moroccan Medical Biology Laboratories in Accordance with the CLP Regulation.

Authors:  Ghita E Mourry; Rachid Alami; Adil Elyadini; Souad El Hajjaji; Saâd El Kabbaj; Mimoun Zouhdi
Journal:  Saf Health Work       Date:  2020-03-27

Review 10.  Assessment of Indoor Air Quality Problems in Office-Like Environments: Role of Occupational Health Services.

Authors:  Paolo Carrer; Peder Wolkoff
Journal:  Int J Environ Res Public Health       Date:  2018-04-12       Impact factor: 3.390

View more