Literature DB >> 19184290

Pivot wear of a centrifugal blood pump developed for circulatory assist.

Takashi Yamane1, Katsunobu Nonaka, Hisashi Miyoshi, Osamu Maruyama, Masahiro Nishida, Ryo Kosaka, Yoshiyuki Sankai, Tatsuo Tsutsui.   

Abstract

We are developing a monopivot centrifugal pump for circulatory assist for a period of more than 2 weeks. The impeller is supported by a pivot bearing at one end and by a passive magnetic bearing at the other. The pivot undergoes concentrated exposure to the phenomena of wear, hemolysis, and thrombus formation. The pivot durability, especially regarding the combination of male/female pivot radii, was examined through rotating wear tests and animal tests. As a result, combinations of similar radii for the male/female pivots were found to provide improved pump durability. In the extreme case, the no-gap combination would result in no thrombus formation.

Entities:  

Mesh:

Year:  2008        PMID: 19184290     DOI: 10.1007/s10047-008-0431-6

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  3 in total

1.  Real-time studies of the pivot bearings in the NEDO Gyro PI-710 centrifugal blood pump.

Authors:  Toshimasa Asai; Kuniyoshi Watanabe; Seiichi Ito; Shinichi Tsujimura; Tadashi Motomura; Toshiyuki Shinohara; Julia A Glueck; Yukihiko Nosé
Journal:  Artif Organs       Date:  2004-10       Impact factor: 3.094

Review 2.  Mechanical circulatory support devices (MCSD) in Japan: current status and future directions.

Authors:  Setsuo Takatani; Hikaru Matsuda; Akihisa Hanatani; Chisato Nojiri; Kenji Yamazaki; Tadashi Motomura; Katsuhiro Ohuchi; Tohru Sakamoto; Takashi Yamane
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

3.  Evaluation of the Wear of the Pivot Bearing in the Gyro C1E3 Pump.

Authors:  K Makinouchi; T Nakazawa; Y Takami; S Takatani; Y Nose
Journal:  Artif Organs       Date:  1996-05       Impact factor: 3.094

  3 in total
  2 in total

Review 1.  Journal of Artificial Organs 2008: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; M Nishimura; T Nishimura; Y Tomizawa; T Yamaoka; H Watanabe
Journal:  J Artif Organs       Date:  2009-03-29       Impact factor: 1.731

2.  Five-week use of a monopivot centrifugal blood pump as a right ventricular assist device in severe dilated cardiomyopathy.

Authors:  Takamichi Inoue; Tadashi Kitamura; Shinzo Torii; Naoji Hanayama; Norihiko Oka; Keiichi Itatani; Takahiro Tomoyasu; Yusuke Irisawa; Miyuki Shibata; Hidenori Hayashi; Minoru Ono; Kagami Miyaji
Journal:  J Artif Organs       Date:  2013-11-28       Impact factor: 1.731

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.