Literature DB >> 19181562

Contact lens induced papillary conjunctivitis with silicone hydrogel lenses.

L Sorbara1, L Jones, D Williams-Lyn.   

Abstract

PURPOSE: To describe the refitting of a soft lens wearer into a silicone hydrogel lens due to neovascularization. This change, in turn, caused contact lens induced papillary conjunctivitis (CLPC) and a further refitting was necessary.
METHODS: The patient was refit into a high Dk surface treated silicone hydrogel with a high modulus value. A second refitting was undertaken into a lower Dk silicone hydrogel contact lens with a lower modulus value which had no surface treatment but incorporated an internal wetting agent.
RESULTS: A high Dk/t lens was used to resolve existing neovascularization and chronic hyperaemia. Subsequently, CLPC response occurred, possibly due to a combination of factors, resulting in irritation of the palpebral conjunctiva. This resulted in temporary lens discontinuation. A second silicone hydrogel lens was fit, along with the use of a non-preserved care system, which led to improvement and eventual resolution of the condition.
CONCLUSION: High Dk silicone hydrogel lenses have shown excellent efficacy in resolving hypoxic complications such as neovascularization and hyperaemia. However, attention needs to be paid to their potential effect on the upper tarsal plate. More than one silicone hydrogel lens may be needed to help resolve these issues.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19181562     DOI: 10.1016/j.clae.2008.07.005

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  6 in total

1.  A novel murine model for contact lens wear reveals clandestine IL-1R dependent corneal parainflammation and susceptibility to microbial keratitis upon inoculation with Pseudomonas aeruginosa.

Authors:  Matteo M E Metruccio; Stephanie J Wan; Hart Horneman; Abby R Kroken; Aaron B Sullivan; Tan N Truong; James J Mun; Connie K P Tam; Robin Frith; Laurence Welsh; Melanie D George; Carol A Morris; David J Evans; Suzanne M J Fleiszig
Journal:  Ocul Surf       Date:  2018-11-12       Impact factor: 5.033

Review 2.  Contact Lens-related Complications: A Review.

Authors:  Fateme Alipour; Saeed Khaheshi; Mahya Soleimanzadeh; Somayeh Heidarzadeh; Sepideh Heydarzadeh
Journal:  J Ophthalmic Vis Res       Date:  2017 Apr-Jun

Review 3.  Advances in chemistry and composition of soft materials for drug releasing contact lenses.

Authors:  Subir Chatterjee; Prashant Upadhyay; Manjul Mishra; Srividya M; M R Akshara; Kamali N; Zahra Sifat Zaidi; Sayeda F Iqbal; Santosh K Misra
Journal:  RSC Adv       Date:  2020-10-06       Impact factor: 4.036

4.  Performance of three multipurpose disinfecting solutions with a silicone hydrogel contact lens.

Authors:  Nery García-Porta; Laura Rico-del-Viejo; Helena Ferreira-Neves; Sofia C Peixoto-de-Matos; Antonio Queirós; José M González-Méijome
Journal:  Biomed Res Int       Date:  2015-03-31       Impact factor: 3.411

Review 5.  Carbon nanotubes hybrid hydrogels in drug delivery: a perspective review.

Authors:  Giuseppe Cirillo; Silke Hampel; Umile Gianfranco Spizzirri; Ortensia Ilaria Parisi; Nevio Picci; Francesca Iemma
Journal:  Biomed Res Int       Date:  2014-01-21       Impact factor: 3.411

6.  Differences in Dry Eye Questionnaire Symptoms in Two Different Modalities of Contact Lens Wear: Silicone-Hydrogel in Daily Wear Basis and Overnight Orthokeratology.

Authors:  Nery García-Porta; Laura Rico-Del-Viejo; Alba Martin-Gil; Gonzalo Carracedo; Jesus Pintor; José Manuel González-Méijome
Journal:  Biomed Res Int       Date:  2016-08-31       Impact factor: 3.411

  6 in total