Literature DB >> 19181269

Detection of sites of infection in mice using 99mTc-labeled PN(2)S-PEG conjugated to UBI and 99mTc-UBI: a comparative biodistribution study.

Laura Meléndez-Alafort1, Anna Nadali, Gianfranco Pasut, Elena Zangoni, Raffaele De Caro, Luca Cariolato, Maria Cecilia Giron, Ignazio Castagliuolo, Francesco M Veronese, Ulderico Mazzi.   

Abstract

UNLABELLED: The antimicrobial peptide ubiquicidin (UBI) directly labeled with technetium-99m ((99m)Tc) has recently been shown to be specifically taken up at sites of infection; however, its chemical structure is not well defined. To address this problem, the aim of the present study was to label UBI using poly(ethyleneglycol)-N-(N-(3-diphenylphosphinopropionyl)glycyl)-S-tritylcysteine ligand (PEG-PN(2)S) in order to compare its ability to detect infection sites with that of (99m)Tc-UBI.
METHODS: The PN(2)S-PEG-UBI conjugate was prepared and labeled with (99m)Tc, and its radiochemical purity was subsequently assessed. The stability of the conjugate to cysteine challenge and dilution with both saline solution and phosphate buffer was determined and serum stability and protein binding were also assessed. In vivo studies were carried out in healthy mice to study the biodistribution of (99m)Tc-PN(2)S-PEG-UBI and its precursor (99m)Tc-PN(2)S-PEG and in infected mice to compare the uptakes of (99m)Tc-UBI and (99m)Tc-PN(2)S-PEG-UBI at the site of infection using scintigraphic imaging and ex vivo tissue counting.
RESULTS: (99m)Tc-PN(2)S-PEG-UBI was obtained with high radiochemical purity (98+/-1%) and high stability. The amphiphilic nature of the conjugate leads to a tendency to form micellar aggregates that explain the high protein binding values obtained. Biodistribution studies in mice showed low renal clearance followed by a predominant reticuloendothelial system clearance that limits its application in the abdominal area. Statistical analysis revealed no significant difference between (99m)Tc-UBI and (99m)Tc-PN(2)S-PEG-UBI uptake in infected mouse thigh, and the site of infection was clearly visualized using scintigraphic imaging.
CONCLUSIONS: (99m)Tc-PN(2)S-PEG-UBI proved to be as effective as (99m)Tc-UBI in detecting sites of infection; however, the well-defined chemical structure of (99m)Tc-PN(2)S-PEG-UBI makes it a better candidate for clinical imaging of infection.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19181269     DOI: 10.1016/j.nucmedbio.2008.10.011

Source DB:  PubMed          Journal:  Nucl Med Biol        ISSN: 0969-8051            Impact factor:   2.408


  5 in total

Review 1.  Recent Progress in the Molecular Imaging of Tumor-Treating Bacteria.

Authors:  Sae-Ryung Kang; Jung-Joon Min
Journal:  Nucl Med Mol Imaging       Date:  2021-01-31

2.  (99m)tc-Ubiquicidin [29-41], a Promising Radiopharmaceutical to Differentiate Orthopedic Implant Infections from Sterile Inflammation.

Authors:  Davood Beiki; Gholamali Yousefi; Babak Fallahi; Mohammad Naghi Tahmasebi; Ali Gholamrezanezhad; Armaghan Fard-Esfahani; Mostafa Erfani; Mohammad Eftekhari
Journal:  Iran J Pharm Res       Date:  2013       Impact factor: 1.696

Review 3.  Polymer therapeutics in surgery: the next frontier.

Authors:  Ernest A Azzopardi; R Steven Conlan; Iain S Whitaker
Journal:  J Interdiscip Nanomed       Date:  2016-04-18

4.  In Vitro and In Vivo Evaluation of 99mTc-Polymyxin B for Specific Targeting of Gram-Bacteria.

Authors:  Sveva Auletta; Filippo Galli; Michela Varani; Giuseppe Campagna; Martina Conserva; Daniela Martinelli; Iolanda Santino; Alberto Signore
Journal:  Biomolecules       Date:  2021-02-05

Review 5.  Functional Imaging in Diagnostic of Orthopedic Implant-Associated Infections.

Authors:  Inga Potapova
Journal:  Diagnostics (Basel)       Date:  2013-10-21
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.