Literature DB >> 19181261

Effective doses in four-dimensional computed tomography for lung radiotherapy planning.

Shinichiro Mori1, Susumu Ko, Takayoshi Ishii, Kanae Nishizawa.   

Abstract

The recent broad adoption of 4-D computed tomography (4DCT) scanning in radiotherapy has allowed the accurate determination of the target volume of tumors by minimizing image degradation caused by respiratory motion. Although the radiation exposure of the treatment beam is significantly greater than that of CT scans used for treatment planning, it is important to recognize and optimize the radiation exposure in 4DCT from the radiological protection point of view. Here, radiation exposure in 4DCT was measured with a 16 multidetector CT. Organ doses were measured using thermoluminescence radiation dosimeter chips inserted at respective anatomical sites of an anthropomorphic phantom. Results were compared with those with the helical CT scan mode. The effective dose measured for 4DCT was 24.7 mSv, approximately four times higher than that for helical CT. However, the increase in treatment accuracy afforded by 4DCT means its use in radiotherapy is inevitable. The patient exposure in the 4DCT could be of value by clarifying the advantage of the treatment planning using 4DCT.

Entities:  

Mesh:

Year:  2008        PMID: 19181261     DOI: 10.1016/j.meddos.2008.08.002

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  6 in total

1.  Dynamic dual-energy chest radiography: a potential tool for lung tissue motion monitoring and kinetic study.

Authors:  Tong Xu; Justin L Ducote; Jerry T Wong; Sabee Molloi
Journal:  Phys Med Biol       Date:  2011-02-01       Impact factor: 3.609

Review 2.  Current status and future prospects of multi-dimensional image-guided particle therapy.

Authors:  Shinichiro Mori; Silvan Zenklusen; Antje-Christin Knopf
Journal:  Radiol Phys Technol       Date:  2013-02-19

3.  Effective and organ doses using helical 4DCT for thoracic and abdominal therapies.

Authors:  Yuka Matsuzaki; Keisuke Fujii; Motoki Kumagai; Ichiro Tsuruoka; Shinichiro Mori
Journal:  J Radiat Res       Date:  2013-04-19       Impact factor: 2.724

4.  Investigating the feasibility of rapid MRI for image-guided motion management in lung cancer radiotherapy.

Authors:  Amit Sawant; Paul Keall; Kim Butts Pauly; Marcus Alley; Shreyas Vasanawala; Billy W Loo; Jacob Hinkle; Sarang Joshi
Journal:  Biomed Res Int       Date:  2014-01-12       Impact factor: 3.411

5.  Reducing radiation dose and enhancing imaging quality of 4DCT for radiation therapy using iterative reconstruction algorithms.

Authors:  George Noid; An Tai; Guang-Pei Chen; Jared Robbins; X Allen Li
Journal:  Adv Radiat Oncol       Date:  2017-04-22

6.  Thoracic Organ Doses and Cancer Risk from Low Pitch Helical 4-Dimensional Computed Tomography Scans.

Authors:  Chengwen Yang; Ransheng Liu; Xin Ming; Ningbo Liu; Yong Guan; Yuanming Feng
Journal:  Biomed Res Int       Date:  2018-09-24       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.