Literature DB >> 19181248

Dosimetric comparison between 3DCRT and IMRT using different multileaf collimators in the treatment of brain tumors.

Meisong Ding1, Francis Newman, Changhu Chen, Kelly Stuhr, Laurie E Gaspar.   

Abstract

We investigated the differences between 3-dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT), and the impact of collimator leaf-width on IMRT plans for the treatment of nonspherical brain tumors. Eight patients treated by 3DCRT with Novalis were selected. We developed 3 IMRT plans with different multileaf collimators (Novalis m3, Varian MLC-120, and Varian MLC-80) with the same treatment margins, number of beams, and gantry positions as in the 3DCRT treatment plans. Treatment planning utilized the BrainLAB treatment planning system. For each patient, the dose constraints and optimization parameters remained identical for all plans. The heterogeneity index, the percentage target coverage, critical structures, and normal tissue volumes receiving 50% of the prescription dose were calculated to compare the dosimetric difference. Equivalent uniform dose (EUD) and tumor control probability (TCP) were also introduced to evaluate the radiobiological effect for different plans. We found that IMRT significantly improved the target dose homogeneity compared to the 3DCRT. However, IMRT showed the same radiobiological effect as 3DCRT. For the brain tumors adjacent to (or partially overlapping with) critical structures, IMRT dramatically spared the volume of the critical structures to be irradiated. In IMRT plans, the smaller collimator leaf width could reduce the volume of critical structures irradiated to the 50% level for those partially overlapping with the brain tumors. For relatively large and spherical brain tumors, the smaller collimator leaf widths give no significant benefit.

Entities:  

Mesh:

Year:  2009        PMID: 19181248     DOI: 10.1016/j.meddos.2007.04.001

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  5 in total

1.  Impact of the high-definition multileaf collimator on linear accelerator-based intracranial stereotactic radiosurgery.

Authors:  J A Tanyi; C M Kato; Y Chen; Z Chen; M Fuss
Journal:  Br J Radiol       Date:  2010-10-05       Impact factor: 3.039

Review 2.  Radiotherapy: Basic Concepts and Recent Advances.

Authors:  S R Mehta; V Suhag; M Semwal; N Sharma
Journal:  Med J Armed Forces India       Date:  2011-07-21

Review 3.  Doses, fractionations, constraints for stereotactic radiotherapy.

Authors:  Simona Borghesi; Cynthia Aristei; Francesco Marampon
Journal:  Rep Pract Oncol Radiother       Date:  2022-03-22

4.  Precision radiotherapy for brain tumors: A 10-year bibliometric analysis.

Authors:  Ying Yan; Zhanwen Guo; Haibo Zhang; Ning Wang; Ying Xu
Journal:  Neural Regen Res       Date:  2012-08-05       Impact factor: 5.135

5.  A Comprehensive Evaluation of the Application of the Halcyon(2.0) IMRT Technique in Long-Course Radiotherapy for Rectal Cancer.

Authors:  Jiajun Zheng; Yuqing Xia; Li Sun
Journal:  Technol Cancer Res Treat       Date:  2022 Jan-Dec
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.