Literature DB >> 19179957

In vitro evaluation of the influence of the cortical bone on the primary stability of two implant systems.

Rodrigo Andrés-García1, Nuria García Vives, Federico Herrero Climent, Ana Fernández Palacín, Vicente Ríos Santos, Mariano Herrero Climent, Pedro Bullón.   

Abstract

AIMS: Immediate loading has become a predictable option for treatment, while one of the main requirements for its implementation is obtaining appropriate primary stability in implants. With that aim, conical implants are commercially available, since, according to specialized literature, they provide greater stability. One of the methods to measure implant stability which has evolved to further stages is resonance frequency analysis (RFA). In the present paper we attempt to evaluate the influence of the cortical bone on the primary stability of two implants of similar diameter and length. STUDY
DESIGN: 15 fresh cow ribs were selected and six different implant beds were prepared in each. These preparations corresponded to two different implant systems: A Swiss Plus from Zimmer Dental and an Mk IV from Nobel Biocare. Two drilling protocols were used for soft bone, hard bone and bone without cortical. After preparing the beds, the implants were placed and implant primary stability was measured with the Osstell mentor.
RESULTS: Higher ISQ (Implant Stability Quotient) values were observed for both implant systems when the cortical bone is maintained than when it is eliminated, the difference being statistically significant in the case of Mk IV implants.
CONCLUSIONS: The results from this study show the importance of preserving cortical bone during drilling in order to obtain greater primary stability.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19179957

Source DB:  PubMed          Journal:  Med Oral Patol Oral Cir Bucal        ISSN: 1698-4447


  10 in total

1.  The effect of implant shape and bone preparation on primary stability.

Authors:  Sang-Hyun Moon; Heung-Sik Um; Jae-Kwan Lee; Beom-Seok Chang; Min-Ku Lee
Journal:  J Periodontal Implant Sci       Date:  2010-10-31       Impact factor: 2.614

2.  A Radiographic and Clinical Comparison of Immediate vs. Early Loading (4 Weeks) of Implants with a New Thermo-Chemically Treated Surface: A Randomized Clinical Trial.

Authors:  Matteo Albertini; Federico Herrero-Climent; Carmen María Díaz-Castro; Jose Nart; Ana Fernández-Palacín; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2021-01-29       Impact factor: 3.390

3.  Assessment of Osstell ISQ's reliability for implant stability measurement: a cross-sectional clinical study.

Authors:  Mariano Herrero-Climent; Rocio Santos-García; Reyes Jaramillo-Santos; Manuel-Maria Romero-Ruiz; Ana Fernández-Palacin; Pedro Lázaro-Calvo; Pedro Bullón; Jose-Vicente Ríos-Santos
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-11-01

4.  The influence of length of implant on primary stability: An in vitro study using resonance frequency analysis.

Authors:  Anwar B Bataineh; Ala M Al-Dakes
Journal:  J Clin Exp Dent       Date:  2017-01-01

5.  In vitro comparison of primary stability of two implant designs in D3 bone.

Authors:  J González-Serrano; R Ortega-Aranegui; J López-Quiles
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-07-01

6.  Repeatability of the resonance frequency analysis values in implants with a new technology.

Authors:  M-C Díaz-Castro; A Falcao; P López-Jarana; C Falcao; J-V Ríos-Santos; A Fernández-Palacín; M Herrero-Climent
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2019-09-01

7.  High-Frequency Ultrasound for Assessment of Peri-Implant Bone Thickness.

Authors:  Juliana Marotti; Sarah Neuhaus; Daniel Habor; Lauren Bohner; Stefan Heger; Klaus Radermacher; Stefan Wolfart
Journal:  J Clin Med       Date:  2019-09-25       Impact factor: 4.241

8.  Effects of Different Undersizing Site Preparations on Implant Stability.

Authors:  Bernardo Ferreira Lemos; Paula Lopez-Jarana; Carlos Falcao; Blanca Ríos-Carrasco; Javier Gil; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2020-12-02       Impact factor: 3.390

9.  Sinus Floor Elevation via an Osteotome Technique without Biomaterials.

Authors:  Rodrigo Andrés-García; José Vicente Ríos-Santos; Mariano Herrero-Climent; Pedro Bullón; Javier Fernández-Farhall; Alberto Gómez-Menchero; Ana Fernández-Palacín; Blanca Ríos-Carrasco
Journal:  Int J Environ Res Public Health       Date:  2021-01-27       Impact factor: 3.390

10.  The effect of implant length and diameter on the primary stability in different bone types.

Authors:  Hamidreza Barikani; Shadab Rashtak; Soolmaz Akbari; Samareh Badri; Niloufar Daneshparvar; Amirreza Rokn
Journal:  J Dent (Tehran)       Date:  2013-09-30
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.