Literature DB >> 19179737

Bubble CPAP - a primary respiratory support for respiratory distress syndrome in newborns.

Prashanth S Urs1, Firdose Khan, P P Maiya.   

Abstract

In preterm infants with respiratory distress syndrome (RDS), the application of continuous positive airway pressure (CPAP) is associated with benefits in terms of reduced respiratory failure and reduced mortality. We conducted this prospective study to evaluate the effectiveness of bubble-CPAP as primary mode of respiratory support. Bubble CPAP was found to be safe and effective means of treating mild and moderate grade RDS, it was also observed to be more successful in babies born to mothers who had received antenatal steroids.

Entities:  

Mesh:

Year:  2009        PMID: 19179737

Source DB:  PubMed          Journal:  Indian Pediatr        ISSN: 0019-6061            Impact factor:   1.411


  15 in total

1.  Outcome of intubate surfactant rapidly extubate (InSuRE): an Indian experience.

Authors:  Amit Tagare; Sandeep Kadam; Umesh Vaidya; Anand Pandit
Journal:  Indian J Pediatr       Date:  2013-06-18       Impact factor: 1.967

2.  Nasal masks or binasal prongs for delivering continuous positive airway pressure in preterm neonates-a randomised trial.

Authors:  Aparna Chandrasekaran; Anu Thukral; M Jeeva Sankar; Ramesh Agarwal; Vinod K Paul; Ashok K Deorari
Journal:  Eur J Pediatr       Date:  2017-01-13       Impact factor: 3.183

3.  Efficacy of a low-cost bubble CPAP system in treatment of respiratory distress in a neonatal ward in Malawi.

Authors:  Kondwani Kawaza; Heather E Machen; Jocelyn Brown; Zondiwe Mwanza; Suzanne Iniguez; Al Gest; E O'Brian Smith; Maria Oden; Rebecca R Richards-Kortum; Elizabeth Molyneux
Journal:  Malawi Med J       Date:  2016-09       Impact factor: 0.875

4.  Intra-gastric pressures in neonates receiving bubble CPAP.

Authors:  Prashant Tyagi; Neeraj Gupta; Akanksha Jain; Pramod Upadhyay; Jacob Puliyel
Journal:  Indian J Pediatr       Date:  2014-09-04       Impact factor: 1.967

5.  A Randomized Trial Comparing Efficacy of Bubble and Ventilator Derived Nasal CPAP in Very Low Birth Weight Neonates with Respiratory Distress.

Authors:  Sheetal Agarwal; Arti Maria; Mahesh K Roy; Ankit Verma
Journal:  J Clin Diagn Res       Date:  2016-09-01

6.  Bubble-CPAP vs. Ventilatory-CPAP in Preterm Infants with Respiratory Distress.

Authors:  Bahareh Bahman-Bijari; Arash Malekiyan; Pedram Niknafs; Mohammad-Reza Baneshi
Journal:  Iran J Pediatr       Date:  2011-06       Impact factor: 0.364

7.  Delivery of heliox with a semi-closed circuit during spontaneous breathing: a comparative economic theoretical study.

Authors:  Ivana Jurickova; Karel Roubík; Martin Muller
Journal:  BMC Pulm Med       Date:  2015-06-10       Impact factor: 3.317

8.  Efficacy of a low-cost bubble CPAP system in treatment of respiratory distress in a neonatal ward in Malawi.

Authors:  Kondwani Kawaza; Heather E Machen; Jocelyn Brown; Zondiwe Mwanza; Suzanne Iniguez; Al Gest; E O'Brian Smith; Maria Oden; Rebecca R Richards-Kortum; Elizabeth Molyneux
Journal:  PLoS One       Date:  2014-01-29       Impact factor: 3.240

9.  Managing severe infection in infancy in resource poor settings.

Authors:  Anna C Seale; James A Berkley
Journal:  Early Hum Dev       Date:  2012-09-30       Impact factor: 2.079

10.  A high-value, low-cost bubble continuous positive airway pressure system for low-resource settings: technical assessment and initial case reports.

Authors:  Jocelyn Brown; Heather Machen; Kondwani Kawaza; Zondiwe Mwanza; Suzanne Iniguez; Hans Lang; Alfred Gest; Neil Kennedy; Robert Miros; Rebecca Richards-Kortum; Elizabeth Molyneux; Maria Oden
Journal:  PLoS One       Date:  2013-01-23       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.