Literature DB >> 19179125

Validation of bioanalytical LC-MS/MS assays: evaluation of matrix effects.

Ann Van Eeckhaut1, Katrien Lanckmans, Sophie Sarre, Ilse Smolders, Yvette Michotte.   

Abstract

Liquid chromatography coupled to atmospheric pressure ionization tandem mass spectrometry is currently the method of choice for the quantitative determination of drugs in biological matrices. The advantages of this technique include high specificity, sensitivity and throughput. However, co-eluting matrix components, which are not observed in the chromatogram, can have a detrimental effect on the analysis, since they can cause ion suppression or enhancement of the analyte. The evaluation of matrix effects on the quantitative analysis of drugs in biological fluids is an important and sometimes overlooked aspect of assay validation. In this review, the influence of matrix effects on bioanalytical LC-MS/MS methods is discussed and illustrated with some examples. In addition, possible solutions to reduce or eliminate matrix effects are highlighted. A literature overview of validated LC-MS/MS methods published from January till June 2008 is also included. Although matrix effects are investigated in most papers, there is no consensus on how matrix effects should be evaluated during method validation. In addition, the definition of specificity should be changed for LC-MS/MS based methods.

Mesh:

Year:  2009        PMID: 19179125     DOI: 10.1016/j.jchromb.2009.01.003

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  59 in total

Review 1.  Current Controversies: Are Free Vitamin Metabolite Levels a More Accurate Assessment of Vitamin D Status than Total Levels?

Authors:  Daniel D Bikle; Sofie Malmstroem; Janice Schwartz
Journal:  Endocrinol Metab Clin North Am       Date:  2017-12       Impact factor: 4.741

2.  Determination of glyphosate in surface water with high organic matter content.

Authors:  Vahur Toss; Ivo Leito; Sergei Yurchenko; Rene Freiberg; Anneli Kruve
Journal:  Environ Sci Pollut Res Int       Date:  2017-02-13       Impact factor: 4.223

3.  LC-MS/MS in the Clinical Laboratory - Where to From Here?

Authors:  Stefan Kg Grebe; Ravinder J Singh
Journal:  Clin Biochem Rev       Date:  2011-02

Review 4.  Biological Matrix Effects in Quantitative Tandem Mass Spectrometry-Based Analytical Methods: Advancing Biomonitoring.

Authors:  Parinya Panuwet; Ronald E Hunter; Priya E D'Souza; Xianyu Chen; Samantha A Radford; Jordan R Cohen; M Elizabeth Marder; Kostya Kartavenka; P Barry Ryan; Dana Boyd Barr
Journal:  Crit Rev Anal Chem       Date:  2016       Impact factor: 6.535

5.  Utilizing Internal Standard Responses to Assess Risk on Reporting Bioanalytical Results from Hemolyzed Samples.

Authors:  Eliza N Fung; Anne-Françoise Aubry; Alban Allentoff; Qin C Ji
Journal:  AAPS J       Date:  2015-05-15       Impact factor: 4.009

Review 6.  The use of mass spectrometry to improve the diagnosis and the management of the HPA axis.

Authors:  Phillip J Monaghan; Brian G Keevil; Peter J Trainer
Journal:  Rev Endocr Metab Disord       Date:  2013-06       Impact factor: 6.514

7.  Automated Online Solid-Phase Derivatization for Sensitive Quantification of Endogenous S-Nitrosoglutathione and Rapid Capture of Other Low-Molecular-Mass S-Nitrosothiols.

Authors:  Xin Wang; Carlos T Garcia; Guanyu Gong; John S Wishnok; Steven R Tannenbaum
Journal:  Anal Chem       Date:  2018-01-09       Impact factor: 6.986

Review 8.  Quantitative mass spectrometry methods for pharmaceutical analysis.

Authors:  Glenn Loos; Ann Van Schepdael; Deirdre Cabooter
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

9.  Rapid quantification of conjugated and unconjugated bile acids and C27 precursors in dried blood spots and small volumes of serum.

Authors:  N Janzen; S Sander; M Terhardt; A M Das; J O Sass; R Kraetzner; H Rosewich; H Rosevich; M Peter; J Sander
Journal:  J Lipid Res       Date:  2010-01-21       Impact factor: 5.922

10.  A rapid and sensitive LC-MS/MS method for quantification of four anthocyanins and its application in a clinical pharmacology study of a bioadhesive black raspberry gel.

Authors:  Yonghua Ling; Chen Ren; Susan R Mallery; Carlos M Ugalde; Ping Pei; U V R Vijaya Saradhi; Gary D Stoner; Kenneth K Chan; Zhongfa Liu
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2009-10-30       Impact factor: 3.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.