Literature DB >> 19178624

Accuracy of impression techniques for implants. Part 2 - comparison of splinting techniques.

Humberto Gennari Filho1, José Vitor Quinelli Mazaro, Eduardo Vedovatto, Wirley Gonçalves Assunção, Paulo Henrique dos Santos.   

Abstract

PURPOSE: The aim of this study was to compare splinting techniques for impression copings of osseointegrated implants with different angulations.
MATERIALS AND METHODS: Replicas (N = 24) of a metal matrix (control) containing two implants at 90 degrees and 65 degrees in relation to the horizontal surface were obtained by using four impression techniques: Technique 1 (T1), direct technique with square copings without union in open trays; Technique 2 (T2), square copings splinted with dental floss and autopolymerizing acrylic resin; Technique 3 (T3),square copings splinted with dental floss and autopolymerizing acrylic resin, sectioned and splinted again with autopolymerizing acrylic resin; Technique 4 (T4), square copings splinted with prefabricated acrylic resin bar. The impression material was polyether. The replicas were individually scanned to capture the images, which were assessed in a graphic computation program. The program allowed the angulation between the bases of the replicas and the reading screws to be measured. The images of the replicas were compared with the matrix image (control), and the differences in angulations from the control image were calculated. The analysis of variance and the Tukey test for comparisons (p < 0.05) were used for statistical analysis.
RESULTS: All groups showed significant differences in the implant angulations in comparison with the control group (p < 0.05). Group T1 showed the highest difference (1.019 degrees ) followed by groups T2 (0.747 degrees ), T3 (0.516 degrees ), and T4 (0.325 degrees ), which showed the lowest angular alteration compared to the control group. There were significant differences between inclined and straight implants in all the groups, except in group T4.
CONCLUSIONS: Based on the results, the splinting of pick-up impression copings is indicated for osseointegrated implant impressions. The square copings splinted with a prefabricated acrylic resin bar presented the best results among the pick-up impression techniques evaluated in this study.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19178624     DOI: 10.1111/j.1532-849X.2008.00325.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  4 in total

1.  Comparison of the accuracy of different impression procedures in case of multiple and angulated implants : Accuracy of impressions in multiple and angulated implants.

Authors:  M Wafa Richi; Sevcan Kurtulmus-Yilmaz; Oguz Ozan
Journal:  Head Face Med       Date:  2020-05-04       Impact factor: 2.151

2.  Comparison of the accuracy of open-tray and snap-on impression techniques of implants with different angulations.

Authors:  Abbass Fallah Tafti; Mahnaz Hatami; Foroughsadat Razavi; Behnaz Ebadian
Journal:  Dent Res J (Isfahan)       Date:  2019-11-12

3.  Accuracy of different impression materials in parallel and nonparallel implants.

Authors:  Mahroo Vojdani; Kianoosh Torabi; Elham Ansarifard
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

4.  Can transfer type and implant angulation affect impression accuracy? A 3D in vitro evaluation.

Authors:  Davide Farronato; Pietro Mario Pasini; Veronica Campana; Diego Lops; Lorenzo Azzi; Mattia Manfredini
Journal:  Odontology       Date:  2021-06-01       Impact factor: 2.634

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.