Contrast transcranial Doppler can diagnose large patent foramen ovale.

Kazuto Kobayashi1, Yasuyuki Iguchi, Kazumi Kimura, Yoko Okada, Yuka Terasawa, Noriko Matsumoto, Kenichirou Sakai, Jyunya Aoki, Kensaku Shibazaki.   

Abstract

BACKGROUND: Contrast transesophageal echocardiography (c-TEE) and contrast transcranial Doppler (c-TCD) are useful diagnostic tools for detecting right-to-left shunts (RLS). However, the diagnostic accuracy of c-TCD for patent foramen ovale (PFO) remains uncertain. We investigated the relationship between the size of PFO determined by c-TEE and c-TCD findings and assessed the detectable rate of RLS by c-TCD.
METHODS: We assessed RLS three times using simultaneous c-TCD and c-TEE in 107 patients (321 examinations). We classified all of ultrasound examinations into three groups by size according to microbubbles on c-TEE, such as no PFO (0 microbubble), small PFO (1-29 microbubbles) and large PFO (>or=30 microbubbles). We also calculated the number of microembolic signals (MES) on c-TCD and evaluated the association between PFO size on c-TEE and MES count on c-TCD.
RESULTS: In the present study, c-TEE detected RLS in 105 (33%; small PFO, n = 78; large PFO, n = 27), and c-TCD detected RLS in 49 (15%) of 321 examinations. Among 78 examinations with small PFO, MES were found in only 19 (24%) on c-TCD. In contrast, of all 27 examinations with large PFO, MES were found on c-TCD. Also, c-TCD were able to detect MES in 3 of 216 examinations among the no-PFO group. When >or=2 MES on c-TCD was established as the cutoff to predict large PFO on c-TEE, the sensitivity, specificity and accuracy were 96.3, 96.8, and 96.9%, respectively.
CONCLUSION: When two or more MES were determined by c-TCD, large PFO could be accurately diagnosed.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19176955     DOI: 10.1159/000196820

Source DB:  PubMed          Journal:  Cerebrovasc Dis        ISSN: 1015-9770            Impact factor:   2.762


  2 in total

1.  Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale.

Authors:  Jiang-Chun He; Jian-Yong Zheng; Xin Li; Ye Yang; Bo-Yang Zhang; Yu Chen; Xian-Feng Li; Ying-Ming Liu; Yi Cao; Li Zhao; Tian-Chang Li
Journal:  Int J Cardiovasc Imaging       Date:  2017-02-07       Impact factor: 2.357

Review 2.  Transcranial Doppler ultrasound: a review of the physical principles and major applications in critical care.

Authors:  Jawad Naqvi; Kok Hooi Yap; Gulraiz Ahmad; Jonathan Ghosh
Journal:  Int J Vasc Med       Date:  2013-12-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.