Literature DB >> 19175841

Single-catheter technique for pulmonary vein antrum isolation: is it sufficient to identify and close the residual gaps without a circular mapping catheter?

Jianzeng Dong1, Xingpeng Liu, Deyong Long, Ronghui Yu, Ribo Tang, Fei Lü, Changsheng Ma.   

Abstract

OBJECTIVES: The present study was designed to investigate the feasibility and efficacy of single ablation catheter for complete circumferential pulmonary vein antrum (PVA) isolation.
BACKGROUND: Complete isolation of pulmonary veins is the mainstay for atrial fibrillation (AF) ablation. This is usually performed under the guidance of a circular catheter.
METHODS: One hundred and ten consecutive patients with paroxysmal AF were prospectively randomized into two groups: single-catheter approach (group 1) and double-catheter approach (group 2). After performing initial circumferential lesions, residual gaps were mapped and closed with single ablation catheter in group 1 or guided by a circular mapping catheter in group 2 using an electroanatomic mapping system (CARTO XP, Biosense-Webster Inc., Diamond Bar, CA, USA).
RESULTS: Complete bilateral PVA isolation was achieved in 22 of the 110 patients after initial ablation. All residual gaps could be correctly identified by activation mapping using single ablation catheter. The distribution of these residual gaps was asymmetric. In group 1, 25 gaps along the right PVA lesions and 49 gaps along the left PVA lesions were identified. All the residual gaps were closed with single-catheter approach. In group 2, 28 gaps on the right side and 53 gaps on the left side were identified using a circular catheter and closed with further ablations. The procedure data and clinical outcomes between the two groups were comparable.
CONCLUSIONS: Single ablation catheter technique is feasible and as effective as circular catheter mapping in localizing the residual gaps for PVA isolation during ablation of paroxysmal AF.

Entities:  

Mesh:

Year:  2008        PMID: 19175841     DOI: 10.1111/j.1540-8167.2008.01324.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  9 in total

1.  Depression, anxiety, and quality of life after catheter ablation in patients with paroxysmal atrial fibrillation.

Authors:  Cai-Hua Sang; Ke Chen; Xue-Feng Pang; Jian-Zeng Dong; Xin Du; Hui Ma; Ji-Hong Liu; Chang-Sheng Ma; Ying-Xian Sun
Journal:  Clin Cardiol       Date:  2012-07-09       Impact factor: 2.882

2.  Remote magnetic navigation for circumferential pulmonary vein ablation: single-catheter technique or additional use of a circular mapping catheter?

Authors:  Dirk Vollmann; Lars Lüthje; Joachim Seegers; Christian Sohns; Samuel Sossalla; Jan Sohns; Christian Röver; Gerd Hasenfuß; Markus Zabel
Journal:  J Interv Card Electrophysiol       Date:  2014-06-04       Impact factor: 1.900

3.  Catheter ablation of atrial fibrillation in patients with atrial septal defect: long-term follow-up results.

Authors:  Jun-Gang Nie; Jian-Zeng Dong; Mohamed Salim; Song-Nan Li; Xiao-Yan Wu; Ying-Wei Chen; Rong Bai; Nian Liu; Xin Du; Chang-Sheng Ma
Journal:  J Interv Card Electrophysiol       Date:  2014-12-13       Impact factor: 1.900

4.  Electrocardiographic left ventricular hypertrophy predicts recurrence of atrial arrhythmias after catheter ablation of paroxysmal atrial fibrillation.

Authors:  Song-Nan Li; Lu Wang; Jian-Zeng Dong; Rong-Hui Yu; De-Yong Long; Ri-Bo Tang; Cai-Hua Sang; Chen-Xi Jiang; Nian Liu; Rong Bai; Xin Du; Chang-Sheng Ma
Journal:  Clin Cardiol       Date:  2018-06-05       Impact factor: 2.882

5.  Remote magnetic versus manual catheter navigation for circumferential pulmonary vein ablation in patients with atrial fibrillation.

Authors:  Lars Lüthje; Dirk Vollmann; Joachim Seegers; Marc Dorenkamp; Christian Sohns; Gerd Hasenfuss; Markus Zabel
Journal:  Clin Res Cardiol       Date:  2011-06-25       Impact factor: 5.460

6.  Differences in Quality of Life Between Atrial Fibrillation Patients with Low Stroke Risk Treated With and Without Catheter Ablation.

Authors:  Ying Bai; Rong Bai; Jia-Hui Wu; Ting Zhang; Nian Liu; Xu-Bo Shi; Xin-Yao Liu; Xiao-Hui Liu; Xin Du; Jian-Zeng Dong; Chang-Sheng Ma
Journal:  J Am Heart Assoc       Date:  2015-09-16       Impact factor: 5.501

Review 7.  Pulmonary Vein Isolation Lesion Set Assessment During Radiofrequency Catheter Ablation for Atrial Fibrillation.

Authors:  Edward Sze; Tristram D Bahnson
Journal:  J Innov Card Rhythm Manag       Date:  2017-02-15

8.  Atrial mapping during pulmonary vein pacing: a novel maneuver to detect and close residual conduction gaps in an ablation line.

Authors:  Jefferson Salas; Eduardo Castellanos; Rafael Peinado; Sergio Madero; Teresa Barrio-López; Mercedes Ortiz; Jesús Almendral
Journal:  J Interv Card Electrophysiol       Date:  2016-07-01       Impact factor: 1.900

9.  Novel Clue to Locate Conduction Gaps in the Pulmonary Vein Isolation Ablation Line.

Authors:  Hai-Yang Xie; Xiao-Gang Guo; Jian-du Yang; Yan-Qiao Chen; Zhong-Jing Cao; Qi Sun; Jian Ma
Journal:  Front Cardiovasc Med       Date:  2021-07-12
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.