Literature DB >> 19175104

3D dynamic model of healthy and pathologic arteries for ultrasound technique evaluation.

Simone Balocco1, Olivier Basset, Jacques Azencot, Piero Tortoli, Christian Cachard.   

Abstract

A 3D model reproducing the biomechanical behavior of human blood vessels is presented. The model, based on a multilayer geometry composed of right generalized cylinders, enables the representation of different vessel morphologies, including bifurcations, either healthy or affected by stenoses. Using a finite element approach, blood flow is simulated by considering a dynamic displacement of the scatterers (erythrocytes), while arterial pulsation due to the hydraulic pressure is taken into account through a fluid-structure interaction based on a wall model. Each region is acoustically characterized using FIELD II software, which produces the radio frequency echo signals corresponding to echographic scans. Three acoustic physiological phantoms of carotid arteries surrounded by elastic tissue are presented to illustrate the model's capability. The first corresponds to a healthy blood vessel, the second includes a 50% stenosis, and the third represents a carotid bifurcation. Examples of M mode, B mode and color Doppler images derived from these phantoms are shown. Two examples of M-mode image segmentation and the identification of the atherosclerotic plaque boundaries on Doppler color images are reported. The model could be used as a tool for the preliminary evaluation of ultrasound signal processing and visualization techniques.

Entities:  

Mesh:

Year:  2008        PMID: 19175104     DOI: 10.1118/1.3006948

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  A Reconstruction Method of Blood Flow Velocity in Left Ventricle Using Color Flow Ultrasound.

Authors:  Jaeseong Jang; Chi Young Ahn; Kiwan Jeon; Jung Heo; DongHak Lee; Chulmin Joo; Jung-il Choi; Jin Keun Seo
Journal:  Comput Math Methods Med       Date:  2015-05-19       Impact factor: 2.238

2.  An Ultrasound Simulation Model for the Pulsatile Blood Flow Modulated by the Motion of Stenosed Vessel Wall.

Authors:  Qinghui Zhang; Yufeng Zhang; Yi Zhou; Kun Zhang; Kexin Zhang; Lian Gao
Journal:  Biomed Res Int       Date:  2016-07-10       Impact factor: 3.411

3.  Simulation of Ultrasound RF Signals Backscattered from a 3D Model of Pulsating Artery Surrounded by Tissue.

Authors:  Monika Makūnaitė; Rytis Jurkonis; Arūnas Lukoševičius; Mindaugas Baranauskas
Journal:  Diagnostics (Basel)       Date:  2022-01-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.